Assessment of cataract surgery outcomes in Nampula (Mozambique): visual acuity, visual function and quality of life

被引:2
作者
Sengo, Dulnerio Barbosa [1 ,2 ]
Saravila, Pires Joao [1 ]
Chivinde, Sancho Sanuel [3 ]
Mate, Laura Mavota [4 ]
Faquihe, Momade Fumo [1 ]
Moragues, Raul [5 ]
Lopez-Izquierdo, Inmaculada [6 ]
Caballero, Pablo [2 ]
机构
[1] Univ Lurio, Fac Ciencias Saude, Bairro Marrere R 4250,Km 2, 3, Nampula 4250, Mozambique
[2] Univ Alacant, Dept Enfermeria Comunitaria Med Prevent & Salud Pu, Carretera St Vicent Raspeig S-N, Alacant 03690, Sant Vicent Del, Spain
[3] Hosp Cent Nampula, Av Samora Machel, Nampula, Mozambique
[4] Minist Combatentes, Av Martires Machava 307, Maputo, Mozambique
[5] Univ Miguel Hernandez, Dept Estadist Matemat & Informat, Av Univ S-N, Elche 03202, Spain
[6] Univ Seville, Dept Fis Mat Condensada, Av Reina Mercedes S-N, Seville 41012, Spain
关键词
Outcomes; Cataract surgery; Visual acuity; Visual function; Quality of life; Nampula; Mozambique; CROSS-CULTURAL ADAPTATION; BLINDNESS; BARRIERS; HEALTH; WORLD;
D O I
10.1007/s00417-022-05964-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Despite advances in surgical techniques, cataract remains the leading cause of preventable blindness, and massive surgeries have been adopted as a strategy to change this situation. Monitoring the results of cataract surgeries has become imperative to ensure their quality. Therefore, this study aims to assess the cataract surgery outcomes performed at the Central Hospital of Nampula Mozambique.Methods This is a prospective and longitudinal study in which translation, cultural adaptation and validation of the visual function (VF) and quality of life (QoL) questionnaire were performed. The appearance, content, construct, criterion, internal consistency and responsiveness were validated using the most common methods and indicators. Visual acuity (VA), VF and QoL were evaluated on 447 patients before and after surgery by t-test and effect sizes.Results VF and QoL questionnaires showed one-dimension, good values of TLI (0.973, 0.951) and SRMR (0.057, 0.054), and for each item, weights > 0.7, H2 > 0.5, ranges > 5.8 and the RMSEA < 0.08. Correlations for criterion validity were high and for responsiveness were high for QoL and moderate for VF one and the ordinal Cronbach's alpha coefficients were greater than 0.97. Difference between VA, VF and QoL before and after surgery was statistically significant (p < 0.001). After surgery, 74.3% of patients had good, 23.5% had borderline and 2.2% had poor VA.Conclusions The cataract surgery outcomes are outside the WHO recommendations regarding VA, but they have had a great impact on improving VF and QoL. The questionnaires showed excellent psychometric properties and should be used in daily clinical practice to evaluate the results of cataract surgeries.
引用
收藏
页码:1597 / 1608
页数:12
相关论文
共 32 条
  • [1] Abdullahi S., 2016, NIGER J OPHTHALMOL, V24, P57, DOI [10.4103/0189-9171.195195, DOI 10.4103/0189-9171.195195]
  • [2] [Anonymous], 2002, Community Eye Health, V15, P49
  • [3] Guidelines for the process of cross-cultural adaptation of self-report measures
    Beaton, DE
    Bombardier, C
    Guillemin, F
    Ferraz, MB
    [J]. SPINE, 2000, 25 (24) : 3186 - 3191
  • [4] Dhaliwal Upreet, 2007, Indian Journal of Ophthalmology, V55, P133
  • [5] ELLWEIN LB, 1994, INT OPHTHALMOL, V18, P263
  • [6] Ferdosh JU., 2019, ASIAN J MED BIOL RES, V5, P212, DOI [10.3329/ajmbr.v5i3.43590, DOI 10.3329/AJMBR.V5I3.43590]
  • [7] Ferraz Ezon Vinícius Alves Pinto, 2002, Arq. Bras. Oftalmol., V65, P293
  • [8] Global causes of blindness and distance vision impairment 1990-2020: a systematic review and meta-analysis
    Flaxman, Seth R.
    Bourne, Rupert R. A.
    Resnikoff, Serge
    Ackland, Peter
    Braithwaite, Tasanee
    Cicinelli, Maria V.
    Das, Aditi
    Jonas, Jost B.
    Keeffe, Jill
    Kempen, John H.
    Leasher, Janet
    Limburg, Hans
    Naidoo, Kovin
    Pesudovs, Konrad
    Silvester, Alex
    Stevens, Gretchen A.
    Tahhan, Nina
    Wong, Tien Y.
    Taylor, Hugh R.
    [J]. LANCET GLOBAL HEALTH, 2017, 5 (12): : E1221 - E1234
  • [9] Measurements of vision function and quality of life in patients with cataracts in southern India - Report of instrument development
    Fletcher, AE
    Ellwein, LB
    Selvaraj, S
    Vijaykumar, V
    Rahmathullah, R
    Thulasiraj, RD
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (06) : 767 - 774
  • [10] Quality of life and visual function in Nigeria: findings from the National Survey of Blindness and Visual Impairment
    Hang My Tran
    Mahdi, Abdull M.
    Sivasubramaniam, Selvaraj
    Gudlavalleti, Murthy V. S.
    Gilbert, Clare E.
    Shah, Shaheen P.
    Ezelum, C. C.
    Abubakar, Tafida
    Bankole, Olufunmilayo O.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (12) : 1646 - 1651