Leveraging High-Density EMG to Investigate Bipolar Electrode Placement for Gait Prediction Models

被引:2
|
作者
Hodossy, Balint K. [1 ]
Guez, Annika S. [2 ,3 ]
Jing, Shibo [2 ,3 ]
Huo, Weiguang [4 ]
Vaidyanathan, Ravi [2 ,3 ]
Farina, Dario [1 ]
机构
[1] Imperial Coll London, Dept Biomed Engn, London SW7 2BX, England
[2] Imperial Coll London, Dept Mech Engn, London SW7 2BX, England
[3] Imperial Coll London, DRI CRT, London SW7 2BX, England
[4] Nankai Univ, Coll Artificial Intelligence, Tianjin 300071, Peoples R China
关键词
Electrodes; Muscles; Measurement; Predictive models; Knee; Electromyography; Standards; Artificial intelligence (AI) and machine learning; human-robot interaction; rehabilitation robotics; sensor networks; signal processing; ROBUST MYOELECTRIC CONTROL; PATTERN-RECOGNITION; CLASSIFICATION; RECORDINGS; SYSTEMS; SHIFT;
D O I
10.1109/THMS.2024.3371099
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
To control wearable robotic systems, it is critical to obtain a prediction of the user's motion intent with high accuracy. Surface electromyography (sEMG) recordings have often been used as inputs for these devices, however bipolar sEMG electrodes are highly sensitive to their location. Positional shifts of electrodes after training gait prediction models can therefore result in severe performance degradation. This study uses high-density sEMG (HD-sEMG) electrodes to simulate various bipolar electrode signals from four leg muscles during steady-state walking. The bipolar signals were ranked based on the consistency of the corresponding sEMG envelope's activity and timing across gait cycles. The locations were then compared by evaluating the performance of an offline temporal convolutional network (TCN) that mapped sEMG signals to knee angles. The results showed that electrode locations with consistent sEMG envelopes resulted in greater prediction accuracy compared to hand-aligned placements (p < 0.01). However, performance gains through this process were limited, and did not resolve the position shift issue. Instead of training a model for a single location, we showed that randomly sampling bipolar combinations across the HD-sEMG grid during training mitigated this effect. Models trained with this method generalized over all positions, and achieved 70% less prediction error than location specific models over the entire area of the grid. Therefore, the use of HD-sEMG grids to build training datasets could enable the development of models robust to spatial variations, and reduce the impact of muscle-specific electrode placement on accuracy.
引用
收藏
页码:192 / 201
页数:10
相关论文
共 50 条
  • [1] Surface EMG vs. High-Density EMG: Tradeoff Between Performance and Usability for Head Orientation Prediction in VR Application
    Sugiarto, Tommy
    Hsu, Chun-Lung
    Sun, Chi-Tien
    Hsu, Wei-Chun
    Ye, Shu-Hao
    Lu, Kuan-Ting
    IEEE ACCESS, 2021, 9 : 45418 - 45427
  • [2] Adaptive Spatial Filtering of High-Density EMG for Reducing the Influence of Noise and Artefacts in Myoelectric Control
    Stachaczyk, Martyna
    Atashzar, S. Farokh
    Farina, Dario
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2020, 28 (07) : 1511 - 1517
  • [3] High-Density Surface EMG Denoising Using Independent Vector Analysis
    Wang, Kun
    Chen, Xun
    Wu, Le
    Zhang, Xu
    Chen, Xiang
    Wang, Z. Jane
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2020, 28 (06) : 1271 - 1281
  • [4] Antagonist Activation Measurement in Triceps Surae Using High-Density and Bipolar Surface EMG in Chronic Hemiparesis
    Ghedira, Mouna
    Vieira, Taian Martins
    Cerone, Giacinto Luigi
    Gazzoni, Marco
    Gracies, Jean-Michel
    Hutin, Emilie
    SENSORS, 2024, 24 (12)
  • [5] Electrode Shift Robust CNN for High-Density Myoelectric Pattern Recognition Control
    Wu, Le
    Liu, Aiping
    Zhang, Xu
    Chen, Xiang
    Chen, Xun
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [6] Design and Characterization of a Textile Electrode System for the Detection of High-Density sEMG
    Cerone, Giacinto Luigi
    Botter, Alberto
    Vieira, Taian
    Gazzoni, Marco
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2021, 29 (29) : 1110 - 1119
  • [7] High-Density EMG Grip Force Estimation During Muscle Fatigue via Domain Adaptation
    Pan, Huiming
    Li, Dongxuan
    Chen, Chen
    Shull, Peter B.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2025, 33 : 925 - 934
  • [8] Prediction of isometric motor tasks and effort levels based on high-density EMG in patients with incomplete spinal cord injury
    Jordanic, Mislav
    Rojas-Martinez, Monica
    Angel Mananas, Miguel
    Francesc Alonso, Joan
    JOURNAL OF NEURAL ENGINEERING, 2016, 13 (04)
  • [9] Fundamental Concepts of Bipolar and High-Density Surface EMG Understanding and Teaching for Clinical, Occupational, and Sport Applications: Origin, Detection, and Main Errors
    Campanini, Isabella
    Merlo, Andrea
    Disselhorst-Klug, Catherine
    Mesin, Luca
    Muceli, Silvia
    Merletti, Roberto
    SENSORS, 2022, 22 (11)
  • [10] A thin, flexible multielectrode grid for high-density surface EMG
    Lapatki, BG
    van Dijk, JP
    Jonas, IE
    Zwarts, MJ
    Stegeman, DF
    JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (01) : 327 - 336