Thermal performance investigation of N-shape double-pipe heat exchanger using Al2O3, TiO2, and Fe3O4-based nanofluids

被引:2
|
作者
Salim, Asif [1 ]
Jihan, Jahidul Islam [1 ]
Das, Barun K. [2 ]
Ahmed, Rasel [1 ,3 ]
机构
[1] Hajee Mohammad Danesh Sci & Technol Univ, Dept Mech Engn, Dinajpur, Bangladesh
[2] Rajshahi Univ Engn & Technol, Dept Mech Engn, Rajshahi, Bangladesh
[3] Hajee Mohammad Danesh Sci & Technol Univ, Dept Mech Engn, Dinajpur 5200, Bangladesh
关键词
exchanger's efficiency; heat exchanger; heat transfer coefficient; nanofluid; N-shape; volume fraction; TRANSFER ENHANCEMENT; WATER NANOFLUID; CONDUCTIVITY; VISCOSITY; FLOW;
D O I
10.1002/ese3.1698
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Researchers and engineers are actively working on enhancing the efficiency of heat exchangers in engineering applications by developing novel designs, exploring new materials, and utilizing nanofluids. Three kinds of nanofluids with varying concentrations are investigated in this paper. The objective is to assess the performance of N-shaped double-pipe heat exchanger used in thermoelectric power plants. The performance has been evaluated using COMSOL Multiphysics software. The findings show that higher nanofluid concentrations resulted in elevated heat transfer coefficients and improved efficiency of N-shape double pipe heat exchanger. The analysis revealed that a mere 1% rise in the volume fraction of nanofluids enhanced the efficiency of the heat exchanger on average 23% when compared to the base fluid (water). In comparison to the N-shape double pipe (Inconel 625) heat exchangers, the N-shape double pipe (copper) heat exchangers appear to be more efficient. The introduction of nanoparticles has a notable impact on the heat transfer coefficients. Specifically, within an N-shaped double pipe (copper) heat exchanger, the inclusion of a 1% volume fraction results in a 2.09% enhancement in the heat transfer coefficient for Al2O3/water, a 1.3% improvement for Fe3O4/water, and a 1.15% increase for TiO2/water. It also exposed that adding 1% Al2O3/water led to a significant 0.623% increase in effectiveness, while TiO2/water showed a 0.259% rise, and Fe3O4/water exhibited a 0.375% improvement. Moreover, increasing the Reynolds number enhances the Nusselt number for Al2O3/water and Fe3O4/water nanofluids by 55.22%, and for TiO2/water by 54.60% at a 6% volume concentration, leading to additional increases in exchanger efficiency. Therefore, the augmentation in nanofluid concentration leads to a reduction in the temperature pinch points both at the intake and outflow. This observation suggests that nanofluids exhibit a superior ability compared to conventional fluids when it comes to effectively lowering temperatures.
引用
收藏
页码:1072 / 1090
页数:19
相关论文
共 50 条
  • [21] Experimental Investigation of Thermal Performance of Microchannel Heat Sink with Nanofluids Al2O3/Water and SiO2/Water
    Thansekhar, M. R.
    Anbumeenakshi, C.
    EXPERIMENTAL TECHNIQUES, 2017, 41 (04) : 399 - 406
  • [22] Convective Flow Boiling Heat Transfer Enhancement with Aqueous Al2O3 and TiO2 Nanofluids: Experimental Investigation
    Mukherjee, Sayantan
    Panda, Smita Rani
    Mishra, Purna Chandra
    Chaudhuri, Paritosh
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2021, 42 (06)
  • [23] Thermal performance of screen mesh heat pipe with Al2O3 nanofluid
    Ghanbarpour, M.
    Nikkam, N.
    Khodabandeh, R.
    Toprak, M. S.
    Muhammed, M.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2015, 66 : 213 - 220
  • [24] Characterization of Al2O3, TiO2, hybrid Al2O3-TiO2 and graphene oxide nanofluids and their performance evaluations in photovoltaic thermal system
    Rubaiee, Saeed
    Yahya, Syed Mohd
    Fazal, M. A.
    Danish, Mohd
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2023, 148 (21) : 11467 - 11477
  • [25] Study on concentric tube heat exchanger heat transfer performance using Al2O3 - water based nanofluids
    Sonawane, Shriram S.
    Khedkar, Rohit S.
    Wasewar, Kailas L.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2013, 49 : 60 - 68
  • [26] Heat transfer studies on double tube heat exchanger with combined effect of propeller insert and water-based GO and Al2O3 nanofluids
    Murthy, H. M. Shankara
    Hegde, Ramakrishna N.
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2022, 47 (03):
  • [27] Experimental investigation of heat transfer and pressure drop in a minichannel heat sink using Al2O3 and TiO2-water nanofluids
    Moghanlou, Farhad Sadegh
    Noorzadehl, Saeed
    Ataei, Mohammad
    Vajdi, Mohammad
    Asl, Mehdi Shahedi
    Esmaeilzadeh, Esmaeil
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2020, 42 (06)
  • [28] Assessment the thermal performance of square twisted double tube heat exchanger with Al2O3 nanofluid
    Razzaq, Ali K. Abdul
    Mushatet, Khudheyer S.
    CHEMICAL PRODUCT AND PROCESS MODELING, 2024, 19 (04): : 653 - 669
  • [29] Modeling of convective turbulent heat transfer of water-based Al2O3 nanofluids in an uniformly heated pipe
    Sekrani, Ghofrane
    Poncet, Sebastien
    Proulx, Pierre
    CHEMICAL ENGINEERING SCIENCE, 2018, 176 : 205 - 219
  • [30] Experimental investigation of heat transfer and pressure drop in a minichannel heat sink using Al2O3 and TiO2–water nanofluids
    Farhad Sadegh Moghanlou
    Saeed Noorzadeh
    Mohammad Ataei
    Mohammad Vajdi
    Mehdi Shahedi Asl
    Esmaeil Esmaeilzadeh
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2020, 42