Safety of using a large femoral head on thin polyethylene for total hip arthroplasty based on different types of polyethylene

被引:1
|
作者
Do, Min Uk [1 ]
Moon, Nam Hoon [2 ]
Suh, Kuen Tak [3 ]
Kim, Jung Shin [1 ]
Lee, Sang-Min [1 ]
Shin, Won Chul [1 ]
机构
[1] Pusan Natl Univ, Sch Med, Res Inst Convergence Biomed Sci & Technol, Dept Orthoped Surg,Yangsan Hosp, 20 Geumo Ro, Yangsan 626770, Gyeongsangnam D, South Korea
[2] Pusan Natl Univ Hosp, Dept Orthoped Surg, Busan, South Korea
[3] Pusan Natl Univ, Sehung Hosp, Dept Orthoped Surg, Sch Med, Busan, South Korea
关键词
CROSS-LINKED POLYETHYLENE; FOLLOW-UP; WEAR; LINERS; DISLOCATION; MINIMUM; RATES; SIZE;
D O I
10.1038/s41598-023-50217-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The use of a large femoral head in total hip arthroplasty (THA) to stabilize and reduce the incidence of dislocation is on the increase, but concerns arise when combining them with small acetabular components due to potential mechanical failures in thin polyethylene (PE) liners. A single-institution, retrospective cohort study was conducted on 116 patients with minimum 2-year follow-up who received 36-mm femoral heads and acetabular components <= 52 mm, using either remelted highly cross-linked polyethylene (remelted HXLPE) or vitamin E-infused HXLPE (VEPE). Osteolysis and implant loosening were not observed in either group. Although a fracture of the PE liner was observed in each group (1.7%), the clinical outcomes were excellent, as the mean modified Harris Hip Score (mHHS) at the last follow-up was 93.5. Moreover, the mean linear wear rates measured by digital imaging software in both groups were low, with 0.035 mm/y in remelted HXLPE and 0.030 mm/y in VEPE. In conclusion, The use of a large femoral head on a thin PE liner can be a viable treatment option in patients who need to prioritize stability; however, careful attention should be paid to mechanical fractures of the PE liner.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Alumina-tantalum composite for femoral head applications in total hip arthroplasty
    Huang, T. S.
    Rahaman, M. N.
    Bal, B. S.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2009, 29 (06): : 1935 - 1941
  • [32] Femoral head diameter considerations for primary total hip arthroplasty
    Girard, J.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (01) : S25 - S29
  • [33] Short-term outcomes of thin highly cross-linked polyethylene liners in primary total hip arthroplasty
    Bieganowski, Thomas
    Singh, Vivek
    Muthusamy, Nishanth
    Kugelman, David N.
    Davidovitch, Roy, I
    Schwarzkopf, Ran
    HIP INTERNATIONAL, 2023, 33 (05) : 839 - 844
  • [34] Medium-term results of ceramic-on-polyethylene Zweymiiller-Plus total hip arthroplasty
    Li, H.
    Zhang, S.
    Wang, X. M.
    Lin, J. H.
    Kou, B. L.
    HONG KONG MEDICAL JOURNAL, 2017, 23 (04) : 333 - 339
  • [35] Impingement and stability of total hip arthroplasty versus femoral head resurfacing using a cadaveric robotics model
    Colbrunn, R. W.
    Bottros, J. J.
    Butler, R. S.
    Klika, A. K.
    Bonner, T. F.
    Greeson, C.
    van den Bogert, A. J.
    Barsoum, W. K.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (07) : 1108 - 1115
  • [36] Fretting Corrosion and Polyethylene Damage Mechanisms in Modular Dual Mobility Total Hip Arthroplasty
    Spece, Hannah
    MacDonald, Daniel W.
    Mont, Michael A.
    Lee, Gwo-Chin
    Kurtz, Steven M.
    BEYOND THE IMPLANT: RETRIEVAL ANALYSIS METHODS FOR IMPLANT SURVEILLANCE, 2018, 1606 : 106 - 117
  • [37] In vivo and ex vivo measurement of polyethylene wear in total hip arthroplasty
    Goldvasser, Dov
    Hansen, Viktor J.
    Noz, Marilyn E.
    Maguire, Gerald Q., Jr.
    Zeleznik, Michael P.
    Olivecrona, Henrik
    Bragdon, Charles R.
    Weidenhielm, Lars
    Malchau, Henrik
    ACTA ORTHOPAEDICA, 2014, 85 (03) : 271 - 275
  • [38] Retrieval Analysis of Sequentially Annealed Highly Crosslinked Polyethylene Used in Total Hip Arthroplasty
    Kurtz, Steven M.
    MacDonald, Daniel W.
    Mont, Michael A.
    Parvizi, Javad
    Malkani, Arthur L.
    Hozack, William
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (03) : 962 - 971
  • [39] Sonographic Detection of Acetabular Polyethylene Liner Dissociation in Total Hip Arthroplasty
    Jin, Wook
    Chun, Young Soo
    Park, So Young
    Rhyu, Kee Hyung
    Park, Ji Seon
    Kim, Hyun Cheol
    Yang, Dal Mo
    Ryu, Kyung Nam
    JOURNAL OF ULTRASOUND IN MEDICINE, 2009, 28 (11) : 1597 - 1600
  • [40] Effect of Taper Design on Trunnionosis in Metal on Polyethylene Total Hip Arthroplasty
    Tan, Sok Chuen
    Teeter, Matthew G.
    Del Balso, Christopher
    Howard, James L.
    Lanting, Brent A.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (07) : 1269 - 1272