A decouple-decomposition noise analysis model for closed-loop mode-localized tilt sensors

被引:5
|
作者
Wang, Kunfeng [1 ,2 ,3 ]
Xiong, Xingyin [1 ]
Wang, Zheng [4 ]
Ma, Liangbo [1 ,2 ]
Wang, Bowen [1 ,2 ]
Yang, Wuhao [1 ]
Bie, Xiaorui [1 ]
Li, Zhitian [1 ]
Zou, Xudong [1 ,2 ,4 ]
机构
[1] Chinese Acad Sci, Aerosp Informat Res Inst, State Key Lab Transducer Technol, Beijing, Peoples R China
[2] Univ Chinese Acad Sci, Sch Elect Elect & Commun Engn, Beijing, Peoples R China
[3] Univ Southern Calif, Ming Hsieh Dept Elect & Comp Engn, Los Angeles, CA USA
[4] QiLu Aerosp Informat Res Inst, Shangdong Key Lab Low Altitude Airspace Surveillan, Jinan, Peoples R China
关键词
D O I
10.1038/s41378-023-00614-z
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The development of mode-localized sensors based on amplitude output metrics has attracted increasing attention in recent years due to the potential of such sensors for high sensitivity and resolution. Mode-localization phenomena leverage the interaction between multiple coupled resonant modes to achieve enhanced performance, providing a promising solution to overcome the limitations of traditional sensing technologies. Amplitude noise plays a key role in determining the resolution of mode-localized sensors, as the output metric is derived from the measured AR (amplitude ratio) within the weakly coupled resonator system. However, the amplitude noise originating from the weakly coupled resonator's closed-loop circuit has not yet been fully investigated. This paper presents a decouple-decomposition (DD) noise analysis model, which is applied to achieve high resolution in a mode-localized tilt sensor based on a weakly coupled resonator closed-loop circuit. The DD noise model separates the weakly coupled resonators using the decoupling method considering the nonlinearity of the resonators. By integrating the decoupled weakly coupled resonators, the model decomposes the weakly coupled resonator's closed-loop circuit into distinct paths for amplitude and phase noise analyses. The DD noise model reveals noise effects at various circuit nodes and models the system noise in the closed-loop circuit of the weakly coupled resonators. MATLAB/Simulink simulations verify the model's accuracy when compared to theoretical analysis. At the optimal operating point, the mode-localized tilt sensor achieves an input-referred instability of 3.91 x 10-4 degrees and an input-referred AR of PSD of 2.01 x 10-4 degrees forward slash root Hz using the closed-loop noise model. This model is also applicable to other varieties of mode-localized sensors.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] A robust sliding mode controller with internal model for closed-loop artificial pancreas
    Abu-Rmileh, Amjad
    Garcia-Gabin, Winston
    Zambrano, Darine
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2010, 48 (12) : 1191 - 1201
  • [22] A robust sliding mode controller with internal model for closed-loop artificial pancreas
    Amjad Abu-Rmileh
    Winston Garcia-Gabin
    Darine Zambrano
    Medical & Biological Engineering & Computing, 2010, 48 : 1191 - 1201
  • [23] Closed-Loop Trailing-Edge Separation Control System Using Empirical Mode Decomposition
    Gupta, Rohit
    Ansell, Phillip J.
    AIAA JOURNAL, 2018, 56 (01) : 121 - 131
  • [24] Estimation of the dynamic matrix and noise model for model predictive control using closed-loop data
    Kadali, R
    Huang, B
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2002, 41 (04) : 842 - 852
  • [25] Closed-Loop Subspace Identification Algorithm of EIV Model Based on Orthogonal Decomposition and PCA
    Wang, Jianguo
    Guo, Yong
    Wang, Juanjuan
    ASIASIM 2012, PT I, 2012, 323 : 55 - 65
  • [26] Performance Analysis of Vibration Sensors for Closed-Loop Feedback Health Monitoring of Mechanical Equipment
    Xiao, Yue
    Li, Yan
    Chu, Changbao
    JOURNAL OF SENSORS, 2021, 2021
  • [27] A current-mode floating-bridge technique for closed-loop ΣΔ readout of Wheatstone bridge sensors
    Raman, J.
    Rombouts, P.
    2019 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2019,
  • [28] Model-Driven Safety Analysis of Closed-Loop Medical Systems
    Pajic, Miroslav
    Mangharam, Rahul
    Sokolsky, Oleg
    Arney, David
    Goldman, Julian
    Lee, Insup
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2014, 10 (01) : 3 - 16
  • [29] Local Sensitivity Analysis of a Closed-Loop in Silico Model of the Human Baroregulation
    Tlalka, Karolina
    Saxton, Harry
    Halliday, Ian
    Xu, Xu
    Taylor, Daniel
    Narracott, Andrew
    Malawski, Maciej
    COMPUTATIONAL SCIENCE, ICCS 2024, PT IV, 2024, 14835 : 173 - 187
  • [30] Dynamic Iterative Principal Components Analysis for Closed-loop, Model Identification
    Katare, Richa
    Maurya, Deepak
    Gudi, Ravindra D. .
    IFAC PAPERSONLINE, 2022, 55 (01): : 393 - 398