Experimental study on performance of different local radiant cooling schemes

被引:10
|
作者
Zhang, Dongkai [1 ]
Li, Cui [2 ]
Li, Zhengrong [2 ]
机构
[1] Hefei Univ Technol, Coll Architecture & Art, Hefei 230009, Anhui, Peoples R China
[2] Tongji Univ, Sch Mech Engn, Shanghai 200092, Peoples R China
关键词
Local radiant cooling; Layout scheme; Thermal comfort; Room thermal characteristics; THERMAL COMFORT; ENERGY-CONSUMPTION; HEATING-SYSTEM; HUMAN RESPONSE; TEMPERATURE; ENVIRONMENT; RADIATION; BEHAVIOR; DESIGN; OFFICE;
D O I
10.1016/j.ijrefrig.2023.04.002
中图分类号
O414.1 [热力学];
学科分类号
摘要
Energy consumption from building cooling is critical for the development of nearly-zero energy building. The indoor zone control of local cooling strategy has been proposed to address this problem. In this study, the application performance of different layout scheme of local radiant cooling was experimentally investigated to explore the optimum design strategy. A series of field experiments were conducted under eight layout schemes of the local radiant cooling considered height, horizontal installation zone, and area of the radiant terminal. The obtained results indicate that in the personnel activity zone (below 2.0 m), local radiant cooling can satisfy the thermal comfort requirements of the occupant. The installation zone has an obvious influence on the room thermal characteristics, whereas the influence from the area was limited. The thermal stability and uniformity of the indoor environment can be improved by modifying the layout of the low and outer zone for the radiant terminal. Increasing the area of the radiant panel is inefficient for the improvement of room thermal characteristics and indoor thermal comfort. The main ranges of the cooling capacity are 115-125 W/m2 for different layout forms of the local radiant terminal and the cooling capacity can be increased by 7%. The layout scheme for the radiant terminal with the outer and low zone can effectively improve the stability of the terminal cooling capacity. Results suggested that the layout scheme of both outer and low zone for the local radiant terminal is crucial to improve the thermal comfort and cooling efficient.
引用
收藏
页码:241 / 252
页数:12
相关论文
共 50 条
  • [31] An Experimental Study on Operating Characteristic of Radiant Floor Cooling Integrated with Underfloor Ventilation System
    Cai, Ning
    Zhang, Dongliang
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2021, 39 (04) : 1207 - 1212
  • [32] Numerical simulation of cooling performance of radiant ceiling system interacting with a ceiling fan
    Guo, Xingguo
    Wan, Shuangshuang
    Chen, Wenhua
    Zhang, Hui
    Arens, Edward
    Cheng, Yuanda
    Pasut, Wilmer
    ENERGY AND BUILDINGS, 2023, 297
  • [33] Experimental comparison of local low velocity unit combined with radiant panel and diffuse ceiling ventilation systems
    Zhao, Weixin
    Kilpelainen, Simo
    Kosonen, Risto
    Jokisalo, Juha
    INDOOR AND BUILT ENVIRONMENT, 2020, 29 (06) : 895 - 914
  • [34] A Comparative Analysis of Machine Learning Algorithms in Predicting the Performance of a Combined Radiant Floor and Fan Coil Cooling System
    Lu, Shengze
    Cui, Mengying
    Gao, Bo
    Liu, Jianhua
    Ni, Ji
    Liu, Jiying
    Zhou, Shiyu
    BUILDINGS, 2024, 14 (06)
  • [35] Experimental comparison of thermal comfort during cooling with a fan coil system and radiant floor system at varying space heights
    Cen, Chao
    Jia, Yihong
    Liu, Kuixing
    Geng, Ruoxi
    BUILDING AND ENVIRONMENT, 2018, 141 : 71 - 79
  • [36] Experimental Verification and Analysis of Thermal Comfort with Radiant Floor Cooling
    Li, Qifen
    Zhou, Zhitian
    Sun, Weidong
    Li, Tao
    Zhao, Lifeng
    Pan, Cuicui
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 4356 - 4363
  • [37] An experimental investigation of application of radiant cooling in hot humid climate
    Vangtook, P
    Chirarattananon, S
    ENERGY AND BUILDINGS, 2006, 38 (04) : 273 - 285
  • [38] Experimental study on control performance comparison between model predictive control and proportion-integral-derivative control for radiant ceiling cooling integrated with underfloor ventilation system
    Zhang, Dongliang
    Huang, Xiaoqing
    Gao, Dongyan
    Cui, Xiaobo
    Cai, Ning
    APPLIED THERMAL ENGINEERING, 2018, 143 : 130 - 136
  • [39] Experimental study on condensation-free radiant cooling panel with low-temperature for local cooling in vehicles-Part 2: Demonstration with passengers for thermal comfort analysis
    Wong, Suet Man
    Gopi, Gineesh
    Kim, Jung Kyung
    Lee, Dongchan
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2025, 160
  • [40] A Comparative Study of Cooling Performance and Thermal Comfort under Street Market Shades and Tree Canopies in Tropical Savanna Climate
    Jareemit, Daranee
    Srivanit, Manat
    SUSTAINABILITY, 2022, 14 (08)