Experimental study on performance of different local radiant cooling schemes

被引:10
|
作者
Zhang, Dongkai [1 ]
Li, Cui [2 ]
Li, Zhengrong [2 ]
机构
[1] Hefei Univ Technol, Coll Architecture & Art, Hefei 230009, Anhui, Peoples R China
[2] Tongji Univ, Sch Mech Engn, Shanghai 200092, Peoples R China
关键词
Local radiant cooling; Layout scheme; Thermal comfort; Room thermal characteristics; THERMAL COMFORT; ENERGY-CONSUMPTION; HEATING-SYSTEM; HUMAN RESPONSE; TEMPERATURE; ENVIRONMENT; RADIATION; BEHAVIOR; DESIGN; OFFICE;
D O I
10.1016/j.ijrefrig.2023.04.002
中图分类号
O414.1 [热力学];
学科分类号
摘要
Energy consumption from building cooling is critical for the development of nearly-zero energy building. The indoor zone control of local cooling strategy has been proposed to address this problem. In this study, the application performance of different layout scheme of local radiant cooling was experimentally investigated to explore the optimum design strategy. A series of field experiments were conducted under eight layout schemes of the local radiant cooling considered height, horizontal installation zone, and area of the radiant terminal. The obtained results indicate that in the personnel activity zone (below 2.0 m), local radiant cooling can satisfy the thermal comfort requirements of the occupant. The installation zone has an obvious influence on the room thermal characteristics, whereas the influence from the area was limited. The thermal stability and uniformity of the indoor environment can be improved by modifying the layout of the low and outer zone for the radiant terminal. Increasing the area of the radiant panel is inefficient for the improvement of room thermal characteristics and indoor thermal comfort. The main ranges of the cooling capacity are 115-125 W/m2 for different layout forms of the local radiant terminal and the cooling capacity can be increased by 7%. The layout scheme for the radiant terminal with the outer and low zone can effectively improve the stability of the terminal cooling capacity. Results suggested that the layout scheme of both outer and low zone for the local radiant terminal is crucial to improve the thermal comfort and cooling efficient.
引用
收藏
页码:241 / 252
页数:12
相关论文
共 50 条
  • [21] Experimental Study on Thermal Comfort with Radiant Cooling Workstation and Desktop Fan in Hot-humid Environment
    Li N.
    He D.
    He Y.
    He M.
    Zhang W.
    Li, Nianping (linianping@126.com), 1600, Hunan University (44): : 198 - 204
  • [22] Theoretical and experimental study of condensation rates on radiant cooling surfaces in humid air
    Tang, Haida
    Liu, Xiao-Hua
    Jiang, Yi
    BUILDING AND ENVIRONMENT, 2016, 97 : 1 - 10
  • [23] Performance Evaluation of Radiant Cooling System Application on a University Building in Indonesia
    Satrio, Pujo
    Sholahudin, S.
    Nasruddin
    RENEWABLE ENERGY TECHNOLOGY AND INNOVATION FOR SUSTAINABLE DEVELOPMENT, 2017, 1826
  • [24] Performance analysis of the refrigerant-cooling radiant terminal: A numerical simulation
    Jiang, Tingting
    You, Shijun
    Wu, Zhangxiang
    Zhang, Huan
    Wang, Yaran
    Wei, Shen
    APPLIED THERMAL ENGINEERING, 2021, 197
  • [25] Experimental Study on Operating Characteristic of a Combined Radiant Floor and Fan Coil Cooling System in a High Humidity Environment
    Zhu, Xuwei
    Liu, Jiying
    Zhu, Xiangyuan
    Wang, Xiaole
    Du, Yanqiu
    Miao, Jikui
    BUILDINGS, 2022, 12 (04)
  • [26] Experimental Study of the Influence of Different Liquids on the Transformer Cooling Performance
    Daghrah, Muhammad
    Wang, Zhongdong
    Liu, Qiang
    Hilker, Andree
    Gyore, Attila
    IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (02) : 588 - 595
  • [27] Thermal Comfort Analysis of Personalized Conditioning System and Performance Assessment with Different Radiant Cooling Systems
    Khare V.R.
    Garg R.
    Mathur J.
    Garg V.
    Energy and Built Environment, 2023, 4 (01): : 111 - 121
  • [28] Radiant vs. All-air cooling systems for highly glazed buildings: An experimental study on global and local thermal comfort
    Shi, Shengqiang
    Merabtine, Abdelatif
    Bennacer, Rachid
    ENERGY CONVERSION AND MANAGEMENT, 2024, 318
  • [29] Experimental investigation on the cooling performance of a novel grooved radiant panel filled with heat transfer liquid
    Lv, Guoquan
    Shen, Chao
    Han, Zhitao
    Liao, Wei
    Chen, Dong
    SUSTAINABLE CITIES AND SOCIETY, 2019, 50
  • [30] Experimental study on radiant cooling with double-skin infrared-transparent membranes
    Guo, Yanling
    Wu, Huijun
    Du, Ke
    Huang, Gongsheng
    Xu, Xinhua
    ENERGY AND BUILDINGS, 2023, 278