Experimental study on performance of different local radiant cooling schemes

被引:10
|
作者
Zhang, Dongkai [1 ]
Li, Cui [2 ]
Li, Zhengrong [2 ]
机构
[1] Hefei Univ Technol, Coll Architecture & Art, Hefei 230009, Anhui, Peoples R China
[2] Tongji Univ, Sch Mech Engn, Shanghai 200092, Peoples R China
关键词
Local radiant cooling; Layout scheme; Thermal comfort; Room thermal characteristics; THERMAL COMFORT; ENERGY-CONSUMPTION; HEATING-SYSTEM; HUMAN RESPONSE; TEMPERATURE; ENVIRONMENT; RADIATION; BEHAVIOR; DESIGN; OFFICE;
D O I
10.1016/j.ijrefrig.2023.04.002
中图分类号
O414.1 [热力学];
学科分类号
摘要
Energy consumption from building cooling is critical for the development of nearly-zero energy building. The indoor zone control of local cooling strategy has been proposed to address this problem. In this study, the application performance of different layout scheme of local radiant cooling was experimentally investigated to explore the optimum design strategy. A series of field experiments were conducted under eight layout schemes of the local radiant cooling considered height, horizontal installation zone, and area of the radiant terminal. The obtained results indicate that in the personnel activity zone (below 2.0 m), local radiant cooling can satisfy the thermal comfort requirements of the occupant. The installation zone has an obvious influence on the room thermal characteristics, whereas the influence from the area was limited. The thermal stability and uniformity of the indoor environment can be improved by modifying the layout of the low and outer zone for the radiant terminal. Increasing the area of the radiant panel is inefficient for the improvement of room thermal characteristics and indoor thermal comfort. The main ranges of the cooling capacity are 115-125 W/m2 for different layout forms of the local radiant terminal and the cooling capacity can be increased by 7%. The layout scheme for the radiant terminal with the outer and low zone can effectively improve the stability of the terminal cooling capacity. Results suggested that the layout scheme of both outer and low zone for the local radiant terminal is crucial to improve the thermal comfort and cooling efficient.
引用
收藏
页码:241 / 252
页数:12
相关论文
共 50 条
  • [1] AN EXPERIMENTAL STUDY ON THE PERFORMANCE OF RADIANT FLOOR COOLING MODULES
    Chien, K. C.
    Chuah, Y. K.
    Chang, W. T.
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2013, 21 (02)
  • [2] Cooling Performance Prediction for Hydraulic Thermoelectric Radiant Cooling Panels with Experimental Validation
    Kim, Minseong
    Kang, Yong-Kwon
    Joung, Jaewon
    Jeong, Jae-Weon
    SUSTAINABILITY, 2022, 14 (23)
  • [3] Experimental Study on Cooling Characteristics of Concrete Ceiling Radiant Cooling Panel
    Su, Lin
    Li, Nianping
    Zhang, Xuhan
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 2168 - 2175
  • [4] The application performance of individualized radiant cooling and heating systems, a review
    Zhang, Dongkai
    Li, Cui
    Li, Zhengrong
    BUILDING AND ENVIRONMENT, 2024, 256
  • [5] Experimental Study on Heat Transfer Characteristics of Radiant Cooling and Heating
    Chen, Shengpeng
    Ma, Xiaohui
    Han, Chaoling
    ENERGIES, 2024, 17 (13)
  • [6] Thermoelectric-Based Radiant Cooling Systems: An Experimental and Numerical Investigation of Thermal Comfort
    Kubwimana, Benjamin
    Seyednezhad, Mohadeseh
    Najafi, Hamidreza
    ENERGIES, 2023, 16 (19)
  • [7] Experimental Study on Performance of Lightweight Radiant Floor Cooling Combined with Underfloor Ventilation System
    Xia, Xue-ying
    Zhang, Xu
    LOW-CARBON CITY AND NEW-TYPE URBANIZATION, 2015, : 307 - 315
  • [8] Study on radiant heat exchange between human body and radiant surfaces under asymmetric radiant cooling environments
    Deng, Yan
    Ding, Yunfei
    Chen, Sihao
    Li, Jing
    Zhou, Chonggang
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 37
  • [9] Thermal comfort of a radiant cooling system in glass fiber reinforced gypsum roof-An experimental study
    Dharmasastha, K.
    Samuel, D. G. Leo
    Nagendra, S. M. Shiva
    Maiya, M. P.
    APPLIED THERMAL ENGINEERING, 2022, 214
  • [10] Cooling Performance Analysis and Optimization of a Room with Radiant Panel using CFD
    Karimi, Abdullah
    Ghias, Reza
    2017 ASHRAE ANNUAL CONFERENCE PAPERS, 2017,