Camera-based Non-contact Respiratory Rate Estimation

被引:0
|
作者
Nirmala, K. [1 ]
Kumar, C. Vinoth [2 ]
Janani, M. [1 ]
Parvathi, A. R. [1 ]
Radhika, B. [1 ]
机构
[1] Sri Sivasubramaniya Nadar Coll Engn, Dept Biomed Engn, Chennai 603110, Tamil Nadu, India
[2] Sri Sivasubramaniya Nadar Coll Engn, Dept Elect & Commun Engn, Chennai 603110, Tamil Nadu, India
关键词
Detrend; Gaussian; Region of interest; Respiratory rate; Spirometer; Zero crossing detection;
D O I
10.1080/03772063.2023.2248934
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A non-contact-based system for estimating the respiration rate of individuals using a mobile phone camera is presented in this paper. Respiration rate is an important vital sign that indicates the number of breaths a person takes per minute and is commonly used in medical assessments. The method involves recording videos of the pit of the neck region using the mobile phone camera and analyzing the changes in light intensity within the video frames. By processing the obtained signals from the video frames, the system accurately estimates the respiration rate. The effectiveness of the proposed method and the estimated respiration rates are compared with rates obtained using two other methods: a spirometer, which is a device used to measure lung function and manual counting. The evaluation is conducted on a group of 34 participants who are instructed to breathe rapidly to simulate varying respiration rates. The results indicate that the presented method achieves an accuracy of over 80% compared with existing state-of-the-art methods. The standard deviation of & PLUSMN;3% suggests a relatively consistent performance across participants. The calculated error between the estimated respiration rates and the reference rates obtained from the spirometer and manual counting validates the reliability of the proposed approach. Additionally, the paper highlights the advantages of this system, including its cost-effectiveness and suitability for remote monitoring and mass screening. The non-contact nature of the method reduces the need for physical contact with patients, which could be especially beneficial in situations where hygiene and infection control are crucial. The paper also outlines plans for future work, which involve validating the method with larger sample sizes and exploring its potential applications in various clinical scenarios.
引用
收藏
页码:5311 / 5320
页数:10
相关论文
共 50 条
  • [21] Non-contact Heart Rate Monitoring with Mobile Phone Camera
    Lin, Shu-Yen
    Tsai, Meng-Ru
    2019 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS - TAIWAN (ICCE-TW), 2019,
  • [22] The in vitro and in vivo validation of a mobile non-contact camera-based digital imaging system for tooth colour measurement
    Smith, Richard N.
    Collins, Luisa Z.
    Naeeni, Mojgan
    Joiner, Andrew
    Philpotts, Carole J.
    Hopkinson, Ian
    Jones, Clare
    Lath, Darren L.
    Coxon, Thomas
    Hibbard, James
    Brook, Alan H.
    JOURNAL OF DENTISTRY, 2008, 36 : S15 - S20
  • [23] Dataset Creation Pipeline for Camera-Based Heart Rate Estimation
    Moustafa, Mohamed
    Elrasad, Amr
    Lemley, Joseph
    Corcoran, Peter
    FIFTEENTH INTERNATIONAL CONFERENCE ON MACHINE VISION, ICMV 2022, 2023, 12701
  • [24] Effects of Video Encoding on Camera-Based Heart Rate Estimation
    Rapczynski, Michel
    Werner, Philipp
    Al-Hamadi, Ayoub
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (12) : 3360 - 3370
  • [25] Research on non-contact respiratory rate measurement method based on video information
    Li S.
    Wang H.
    Liu Y.
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2021, 38 (06): : 1173 - 1180
  • [26] Non-contact heart rate and respiratory monitoring based on Imaging Photoplethysmography at fingertip
    Qiao WenLong
    Zhou Liang
    Liu Zhaohui
    Yu Jiangjun
    Sun Xiaoxiao
    AOPC 2020: OPTICAL SPECTROSCOPY AND IMAGING; AND BIOMEDICAL OPTICS, 2020, 11566
  • [27] Vision-based automatic detection method for non-contact respiratory rate
    Liu J.
    Liu H.
    Jia X.
    Guo S.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2019, 40 (02): : 51 - 58
  • [28] Camera-based weight estimation
    Laufer, Patrick
    VDI Berichte, 2022, 2022 (2407): : 291 - 298
  • [29] Non-Contact Respiratory Measurement Using a Depth Camera for Elderly People
    Imano, Wakana
    Kameyama, Kenichi
    Hollingdal, Malene
    Refsgaard, Jens
    Larsen, Knud
    Topp, Cecilie
    Kronborg, Sissel Hojsted
    Gade, Josefine Dam
    Dinesen, Birthe
    SENSORS, 2020, 20 (23) : 1 - 12
  • [30] Non-contact respiratory rate and heart rate signal acquisition system
    Guo J.
    Chen Y.-H.
    Wang L.-R.
    Wei Y.
    Guo Y.
    Zhao Y.-M.
    Liu L.-L.
    Chen X.-H.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2019, 27 (06): : 1354 - 1361