Comparison of Uterine manipulators types in total Laparoscopic Hysterectomy: A retrospective study

被引:1
作者
Sengul, Mustafa [1 ]
Sen Selim, Halime [2 ]
机构
[1] Izmir Katip Celebi Univ, Obstet & Gynecol Dept, Basin Sitesi Mah, Izmir, Turkiye
[2] Izmir Katip Celebi Univ, Ataturk Training & Res Hosp, Obstet & Gynecol Dept, Basin Sitesi Mah, Izmir, Turkiye
关键词
Hysterectomy; Laparoscopic hysterectomy; Uterine manipulators; SURGERY;
D O I
10.12669/pjms.39.4.6728
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To compare the results of operations of commercial uterine manipulators. Considering that the optimal uterine manipulator is still not found, our goal was to give an idea for gynecologists to choose the most suitable uterine manipulator for their purposes and expectations.Methods: Between January 2016 and September 2021, 294 laparoscopic hysterectomy cases met the inclusion criteria and were operated in Izmir Katip celebi University Ataturk Training and Research Hospital Gynecology and Obstetrics Clinic. They were divided into four groups according to the type of manipulator used. Group-1 (RUMI-I), Group-2 (Clermont-Ferrand), Group-3 (sharp intrauterine curette-tenaculum), and Group-4 (without uterine manipulator). All four groups were compared with operation time, hospital stay, absolute change in hemoglobin (g/dl), and per-op complications.Results: Considering the operation times in all groups, the mean operation time in the first Group-was 180 minutes (98-349); in Group-2 was 159 minutes (96-564); in the 3rd Group was 178 minutes (141-540); in the 4th Group was 189 minutes (115-453). The group with the shortest operation time was Group-2; the difference was statistically significant (p=0.015). In general terms, the effect of all manipulators on patient parameters wasn't very different. Clermont-Ferrand seems more advantageous than others in making the surgeon's work more straightforward regarding operation time only.Conclusions: In our study, the choice of uterine manipulator did not affect the surgical results except for the duration of the operation. The personalization of uterine manipulators according to the needs of the surgery and the easiness of use of the surgeon should be at the forefront.
引用
收藏
页码:961 / 966
页数:6
相关论文
共 23 条
  • [1] [Anonymous], 2009, Obstet Gynecol, V114, P1156, DOI 10.1097/AOG.0b013e3181c33c72
  • [2] Aslan M, 2021, LAPAROSCOPIC ENDOSCO, V28, P18, DOI [10.14744/less.2021.85698, DOI 10.14744/LESS.2021.85698]
  • [3] Uterine manipulator requirement in laparoscopic surgery of Ectopic Pregnancy
    Beyan, Emrah
    Kanmaz, Ahkam Goksel
    Budak, Adnan
    Emirdar, Volkan
    Tutar, Sadettin Oguzhan
    Inan, Abdurrahman Hamdi
    [J]. PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2020, 36 (02) : 105 - 110
  • [4] Burnham W, 1854, NELSONS AM LANCET, V8, P147
  • [5] Home within 24 hours of laparoscopic hysterectomy
    Chou, DCY
    Rosen, DMB
    Cario, GM
    Carlton, MA
    Lam, AM
    Chapman, M
    Johns, C
    [J]. AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 1999, 39 (02) : 234 - 238
  • [6] Recommendations to Prevent Urinary Tract Injuries During Laparoscopic Hysterectomy: A Systematic Delphi Procedure Among Experts
    Janssen, P. F.
    Brolmann, H. A. M.
    Huirne, J. A. F.
    [J]. JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2011, 18 (03) : 314 - 321
  • [7] Kang Hye Won, 2016, Obstet Gynecol Sci, V59, P39, DOI 10.5468/ogs.2016.59.1.39
  • [8] Karl Storz GmbH & Co. KG, US
  • [9] Total laparoscopic hysterectomy without uterine manipulator: description of a new technique and its outcome
    Kavallaris, Andreas
    Chalvatzas, N.
    Kelling, K.
    Bohlmann, M. K.
    Diedrich, K.
    Hornemann, A.
    [J]. ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2011, 283 (05) : 1053 - 1057
  • [10] Khanum Z, 2015, ANN KING EDWARD MED, V21, P253