Seismic performance of fabricated continuous girder bridge with grouting sleeve-prestressed tendon composite connections

被引:1
作者
Wang, Jin [1 ]
Xu, Weibing [2 ,3 ]
Du, Xiuli [2 ,3 ]
Chen, Yanjiang [2 ,3 ]
Ding, Mengjia [2 ]
Fang, Rong [2 ]
Yang, Guang [2 ]
机构
[1] North China Elect Power Univ, Sch Water Resources & Hydropower Engn, Beijing 102206, Peoples R China
[2] Beijing Univ Technol, Beijing Key Lab Earthquake Engn & Struct Retrofit, Beijing 100124, Peoples R China
[3] Beijing Univ Technol, Key Lab Urban Secur & Disaster Engn China, Minist Educ, Beijing 100124, Peoples R China
基金
中国国家自然科学基金;
关键词
seismic performance; continuous girder bridge; grouting sleeve-prestressed tendon composite connections; grouted sleeve connection; design parameters; PRECAST; PIERS; BEHAVIOR; COLUMNS; CONSTRUCTION; RESPONSES; JOINTS;
D O I
10.1007/s11709-023-0954-1
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The seismic performance of a fully fabricated bridge is a key factor limiting its application. In this study, a fiber element model of a fabricated concrete pier with grouting sleeve-prestressed tendon composite connections was built and verified. A numerical analysis of three types of continuous girder bridges was conducted with different piers: a cast-in-place reinforced concrete pier, a grouting sleeve-fabricated pier, and a grouting sleeve-prestressed tendon composite fabricated pier. Furthermore, the seismic performance of the composite fabricated pier was investigated. The results show that the OpenSees fiber element model can successfully simulate the hysteresis behavior and failure mode of the grouted sleeve-fabricated pier. Under traditional non-near-fault ground motions, the pier top displacements of the grouting sleeve-fabricated pier and the composite fabricated pier were less than those of the cast-in-place reinforced concrete pier. The composite fabricated pier had a good self-centering capability. In addition, the plastic hinge zones of the grouting sleeve-fabricated pier and the composite fabricated pier shifted to the joint seam and upper edge of the grouting sleeve, respectively. The composite fabricated pier with optimal design parameters has good seismic performance and can be applied in high-intensity seismic areas; however, the influence of pile-soil interaction on its seismic performance should not be ignored.
引用
收藏
页码:827 / 854
页数:28
相关论文
共 49 条
  • [1] Abdelkarim O I., 2014, S SUST INFR FIB REIN, P185
  • [2] Shifted Plastic Hinging for Grouted Sleeve Column Connections
    Al-Jelawy, Haider M.
    Mackie, Kevin R.
    Haber, Zachary B.
    [J]. ACI STRUCTURAL JOURNAL, 2018, 115 (04) : 1101 - 1114
  • [3] Behavior of Prefabricated Full-Depth Precast Concrete Bridge Deck Panel System: Optimum Prestress Level
    Al-Rousan, Rajai
    [J]. 1ST INTERNATIONAL CONFERENCE ON OPTIMIZATION-DRIVEN ARCHITECTURAL DESIGN (OPTARCH 2019), 2020, 44 : 607 - 614
  • [4] Ameli MJ, 2015, PCI J, P80
  • [5] [Anonymous], 2004, J SEISMOLOGY EARTHQU
  • [6] Benjumea José, 2020, Dyna rev.fac.nac.minas, V87, P80, DOI 10.15446/dyna.v87n212.80143
  • [7] Cyclic Loading Test of Unbonded and Bonded Posttensioned Precast Segmental Bridge Columns with Circular Section
    Bu, Zhan-Yu
    Ou, Yu-Chen
    Song, Jian-Wei
    Zhang, Na-Si
    Lee, George C.
    [J]. JOURNAL OF BRIDGE ENGINEERING, 2016, 21 (02)
  • [8] Two-plastic-hinge and two dimensional finite element models for post-tensioned precast concrete segmental bridge columns
    Chou, Chung-Che
    Chang, Hao-Jan
    Hewes, Joshua T.
    [J]. ENGINEERING STRUCTURES, 2013, 46 : 205 - 217
  • [9] Behavior of Segmental Precast Posttensioned Bridge Piers under Lateral Loads
    Dawood, Haitham
    ElGawady, Mohamed
    Hewes, Joshua
    [J]. JOURNAL OF BRIDGE ENGINEERING, 2012, 17 (05) : 735 - 746
  • [10] Experimental research on seismic performance of precast cogging high-strength bolt composite joint and influence of its arrangement location
    Ding, Yingnan
    Xu, Weibing
    Chen, Yanjiang
    Wang, Jin
    Yan, Weiming
    [J]. ENGINEERING STRUCTURES, 2020, 225