The Utility of Arterial Transit Time Measurement for Evaluating the Hemodynamic Perfusion State of Patients with Chronic Cerebrovascular Stenosis or Occlusive Disease: Correlative Study between MR Imaging and 15O-labeled H2O Positron Emission Tomography

被引:6
|
作者
Takeuchi, Kayo [1 ]
Isozaki, Makoto [2 ]
Higashino, Yoshifumi [2 ]
Kosaka, Nobuyuki [1 ]
Kikuta, Ken-ichiro [2 ]
Ishida, Shota [3 ]
Kanamoto, Masayuki [3 ]
Takei, Naoyuki [4 ]
Okazawa, Hidehiko [5 ]
Kimura, Hirohiko [1 ]
机构
[1] Univ Fukui, Fac Med Sci, Dept Radiol, 23-3 Matsuokashimoaizuki,Eiheiji Cho, Fukui 9101193, Japan
[2] Univ Fukui, Fac Med Sci, Dept Neurosurg, Fukui, Japan
[3] Univ Fukui Hosp, Radiol Ctr, Fukui, Japan
[4] GE Healthcare, Global MR Applicat & Workflow, Tokyo, Japan
[5] Univ Fukui, Biomed Imaging Res Ctr, Fukui, Japan
基金
日本学术振兴会;
关键词
arterial spin labeling; arterial transit time; magnetic resonance imaging; cerebral blood flow; oxygen extraction fraction; CEREBRAL-BLOOD-FLOW; ARTERIOVENOUS-MALFORMATIONS; MISERY-PERFUSION; PARAMETERS; STROKE; VOLUME;
D O I
10.2463/mrms.mp.2020-0123
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To verify whether arterial transit time (ATT) mapping can correct arterial spin labeling-cerebral blood flow (ASL-CBF) values and to verify whether ATT is a parameter that correlates with positron emission tomography (PET)-oxygen extraction fraction (OEF) and PET-mean transit time (MTT).Methods: Eleven patients with unilateral major cerebral artery stenosis or occlusion underwent MRI and PET in the chronic or asymptomatic phase. ASL-MRI acquisitions were conducted with each of two post-label delay (PLD) settings (0.7s and 2.0s) using a pseudo-continuous ASL pulse sequence and 3D-spin echo spiral readout with vascular crusher gradient. ATT maps were obtained using a low-resolution pre-scan approach with five PLD settings. Using the ASL perfusion images and ATT mapping, ATT-corrected ASL-CBF images were obtained. Four kinds of ASL-CBF methods (PLD 0.7s with or without ATT correction and PLD 2.0s with or without ATT correction) were compared to PET-CBF, using vascular territory ROIs. ATT and OEF were compared for all ROIs, unaffected side ROIs, and affected side ROIs, respectively. ATT and MTT were compared by the ratio of the affected side to the unaffected side. Transit time-based ROIs were used for the comparison with ATT.Results: Comparing ASL-CBF and PET-CBF, the correlation was higher with ATT correction than without correction, and for a PLD of 2.0s compared with 0.7s. The best correlation was for PLD of 2.0s with ATT correction (R2 = 0.547). ROIs on the affected side showed a low but significant correlation between ATT and PET-OEF (R2 = 0.141). There was a low correlation between the ATT ratio and the MTT ratio (R2 = 0.133).Conclusion: Low-resolution ATT correction may increase the accuracy of ASL-CBF measurements in patients with unilateral major cerebral artery stenosis or occlusion. In addition, ATT itself might have a potential role in detecting compromised hemodynamic state.
引用
收藏
页码:289 / 300
页数:12
相关论文
共 6 条
  • [1] Clinical impact of hemodynamic parameter measurement for cerebrovascular disease using positron emission tomography and 15O-labeled tracers
    Okazawa, Hidehiko
    Kudo, Takashi
    ANNALS OF NUCLEAR MEDICINE, 2009, 23 (03) : 217 - 227
  • [2] Clinical impact of hemodynamic parameter measurement for cerebrovascular disease using positron emission tomography and 15O-labeled tracers
    Hidehiko Okazawa
    Takashi Kudo
    Annals of Nuclear Medicine, 2009, 23 : 217 - 227
  • [3] Preserved acetazolamide reactivity in lacunar patients with severe white-matter lesions: 15O-labeled gas and H2O positron emission tomography studies
    Nezu, Tomohisa
    Yokota, Chiaki
    Uehara, Toshiyuki
    Yamauchi, Miho
    Fukushima, Kazuhito
    Toyoda, Kazunori
    Matsumoto, Masayasu
    Iide, Hidehiro
    Minematsu, Kazuo
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2012, 32 (05) : 844 - 850
  • [4] TIME DEPENDENCY OF THE ACETAZOLAMIDE EFFECT ON CEREBRAL HEMODYNAMICS IN PATIENTS WITH CHRONIC OCCLUSIVE CEREBRAL-ARTERIES - EARLY STEAL PHENOMENON DEMONSTRATED BY [O-15]H2O POSITRON EMISSION TOMOGRAPHY
    KUWABARA, Y
    ICHIYA, Y
    SASAKI, M
    YOSHIDA, T
    MASUDA, K
    STROKE, 1995, 26 (10) : 1825 - 1829
  • [5] Whole-Brain Perfusion Measurement Using 320-Detector Row Computed Tomography in Patients With Cerebrovascular Steno-Occlusive Disease: Comparison With 15O-Positron Emission Tomography
    Shinohara, Yuki
    Ibaraki, Masanobu
    Ohmura, Tomomi
    Sugawara, Shigeki
    Toyoshima, Hideto
    Nakamura, Kazuhiro
    Kinoshita, Fumiko
    Kinoshita, Toshibumi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (06) : 830 - 835
  • [6] Spatial coefficient of variation in pseudo-continuous arterial spin labeling cerebral blood flow images as a hemodynamic measure for cerebrovascular steno-occlusive disease: A comparative 15O positron emission tomography study
    Ibaraki, Masanobu
    Nakamura, Kazuhiro
    Toyoshima, Hideto
    Takahashi, Kazuhiro
    Matsubara, Keisuke
    Umetsu, Atsushi
    Pfeuffer, Josef
    Kuribayashi, Hideto
    Kinoshita, Toshibumi
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2019, 39 (01) : 173 - 181