Automated and rapid chemiluminescence immunoassay for cardiac troponin I based on digital microfluidics

被引:5
|
作者
Cheng, Kangning [1 ]
Ding, Yue [1 ]
Liu, Cong [1 ]
Ding, Yanjing [1 ]
Xie, Shuqi [1 ]
Zhu, Xiaofeng [1 ]
Liu, Huanqing [1 ]
Yue, Weiwei [1 ]
机构
[1] Shandong Normal Univ, Sch Phys & Elect, Jinan 250358, Peoples R China
基金
中国国家自然科学基金;
关键词
Digital microfluidics; Electrowetting-on-dielectric; Cardiac troponin I; Magnetic beads; Double antibody sandwich strategy; Chemiluminescence; ACUTE MYOCARDIAL-INFARCTION; PLURONIC ADDITIVES; IMMUNOSENSOR; CHROMATOGRAPHY; DROPLETS;
D O I
10.1007/s10404-023-02652-5
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Rapid diagnosis of acute myocardial infarction (AMI) is critical in the clinical setting. An automated and rapid chemiluminescence immunoassay system based on digital microfluidics (DMF) is suggested for cardiac troponin I (cTnI). This method involves a double antibody sandwich structure. The cTnI antigen in the sample to be analyzed was captured by magnetic beads encapsulated with the cTnI antibody, which was subsequently recognized by the biotin-labeled secondary antibody. Horseradish peroxidase (HRP)-labeled streptavidin may be conjugated to biotin and used to mark the cTnI antigen because of the unique way that biotin binds to avidin. The simultaneous recognition of the cTnI antigen by primary and secondary antibodies in sandwich form, as well as the high specificity of the reaction between streptavidin and biotin, considerably improves the sensitivity and specificity of this technique for cTnI detection. This approach has decent stability. For cTnI samples, the full process took 40 min, with a limit of detection (LOD) of 0.34 ng mL(-1). Additionally, there was a significant correlation range from 0.39 to 25 ng mL(-1), with a correlation value of 0.994. The CV (Coefficient of variation) value was 2.26%. This system is anticipated to be used for the clinical measurement of cTnI in human serum.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Development of a Qualitative Sequential Immunoassay for Characterizing the Intrinsic Properties of Circulating Cardiac Troponin I
    Lin, Yixin
    Fu, Qin
    Zhu, Jie
    Miller, Julie M.
    Van Eyk, Jennifer E.
    CLINICAL CHEMISTRY, 2010, 56 (08) : 1307 - 1319
  • [32] Fully Automated Quantification of Insulin Concentration Using a Microfluidic-Based Chemiluminescence Immunoassay
    Yao, Ping
    Liu, Zhu
    Tung, Steve
    Dong, Zaili
    Liu, Lianqing
    JALA, 2016, 21 (03): : 387 - 393
  • [33] Active droplet-array microfluidics-based chemiluminescence immunoassay for point-of-care detection of procalcitonin
    Huang, Enqi
    Huang, Dezhi
    Wang, Yu
    Cai, Dongyang
    Luo, Yanzhang
    Zhong, Zhimin
    Liu, Dayu
    BIOSENSORS & BIOELECTRONICS, 2022, 195
  • [34] Interference of laboratory disinfection with trichloro-isocyanuric acid on cardiac troponin I measurement using the Vitros immunoassay system
    Zhao, Zhen
    Pan, Huifen
    Gu, Wenhong
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (04) : E80 - E83
  • [35] Immunoassay for Cardiac Troponin I with Fluorescent Signal Amplification by Hydrolyzed Coumarin Released from a Metal-Organic Framework
    Wang, Xujie
    Wang, Xiaoying
    Han, Ying
    Li, He
    Kang, Qing
    Wang, Pengcheng
    Zhou, Feimeng
    ACS APPLIED NANO MATERIALS, 2019, 2 (11): : 7170 - 7177
  • [36] An automated magnetic beads-based chemiluminescence immunoassay system for simultaneous quantification of multi-mycotoxins in agricultural products
    Liu, Hongmei
    Shi, Yakun
    Ye, Jin
    Ni, Baoxia
    Xuan, Zhihong
    Li, Feng
    Wang, Songxue
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 420
  • [37] An electrochemical metallic nanowire aptasensor for rapid and ultrasensitive detection of cardiac troponin I
    Zhang, Junfeng
    Sun, Kai
    Ren, Jiangtao
    Wang, Han
    Cheng, Jing
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 401
  • [38] Highly sensitive detection of cardiac troponin I in human serum using gold nanoparticle-based enhanced sandwich immunoassay
    Kim, Wan-Joong
    Cho, Hyo Young
    Kim, Bong Kyu
    Huh, Chul
    Chung, Kwang Hyo
    Ahn, Chang-Geun
    Kim, Young Jun
    Kim, Ansoon
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 537 - 543
  • [39] Thionin functionalized signal amplification label derived dual-mode electrochemical immunoassay for sensitive detection of cardiac troponin I
    Lv, Hui
    Li, Yueyun
    Zhang, Xiaobo
    Li, Xinjin
    Xu, Zhen
    Chen, Lei
    Li, Degang
    Dong, Yunhui
    BIOSENSORS & BIOELECTRONICS, 2019, 133 : 72 - 78
  • [40] Wavelength modulation based surface plasmon resonance sensor for detection of cardiac marker proteins troponin I and troponin T
    Sinha, Rajeev K.
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 332 (332)