Load Frequency Control Using Golden Eagle Optimization for Multi-Area Power System Connected Through AC/HVDC Transmission and Supported With Hybrid Energy Storage Devices

被引:14
|
作者
Khan, Irfan Ahmed [1 ]
Mokhlis, Hazlie [1 ,2 ]
Mansor, Nurulafiqah Nadzirah [1 ]
Illias, Hazlee Azil [1 ]
Usama, Muhammad [1 ,3 ]
Daraz, Amil [4 ]
Wang, Li [4 ,5 ]
Awalin, Lilik Jamilatul [2 ]
机构
[1] Univ Malaya, Fac Engn, Dept Elect Engn, Kuala Lumpur 50603, Malaysia
[2] Univ Airlangga, Fac Adv Technol & Multidiscipline, Gedung Kuliah Bersama UNAIR Kampus C, Surabaya 60155, Indonesia
[3] Constituent Coll Univ Engn & Technol, Rachna Coll Engn & Technol, Dept Elect Engn, Lahore 52250, Pakistan
[4] Ningbo Tech Univ, Sch Informat Sci & Engn, Ningbo 315100, Peoples R China
[5] Natl Cheng Kung Univ, Dept Elect Engn, Tainan 70101, Taiwan
关键词
Power system stability; Frequency control; Optimization; Energy storage; HVDC transmission; Mathematical models; Hybrid power systems; Energy storage system; golden eagle optimization; load frequency control; super magnetic energy storage system (SMES); vanadium redox flow battery; AUTOMATIC-GENERATION CONTROL; PID CONTROLLER; IMPLEMENTATION; STABILIZATION; DESIGN;
D O I
10.1109/ACCESS.2023.3272836
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The reliability of a power system depends on its ability to handle fluctuations and varying load demands, as uncontrolled frequency deviations can lead to load-shedding and blackouts. Optimally tuned controllers are essential for Load Frequency Control (LFC) applications to efficiently stabilize the power system by minimizing frequency undershoots, overshoots, and settling time. This paper proposed the application of novel Golden Eagle Optimization (GEO) algorithm for the optimal tuning of the LFC controller, which has not been previously employed in any LFC applications. Moreover, this paper presents the first-ever implementation of a hybrid energy storage system consisting of Vanadium Redox Flow Battery (VRFB) and Super Magnetic Energy Storage System (SMES) coupled with AC/HVDC transmission lines in a multi-area power system. A GEO optimized Proportional-Integrative-Derivative (GEO-PID) robust controller is designed with the Integral Time Absolute Error (ITAE) objective function to enhance the power system's stability. The proposed controller is tested on two and four areas power systems considering the sensitivity and nonlinearity of the power systems. A robustness test is also performed to verify the stability of the system under randomly chosen loading conditions. In comparison with particle swarm optimization, dragonfly algorithm, sine cosine algorithm, ant lion optimization, and whale optimization algorithm, the GEO-PID controller significantly reduced the settling time up to 80% for different area's frequencies. Simulation results indicate that the proposed controller outperforms other recent optimization algorithms by effectively dampening the frequency and tie-line deviations with less settling times, as well as reduced frequency undershoots and overshoots.
引用
收藏
页码:44672 / 44695
页数:24
相关论文
共 50 条
  • [21] Robust Distributed Load Frequency Control for Multi-Area Power Systems with Photovoltaic and Battery Energy Storage System
    Lan, Yunrui
    Illindala, Mahesh S.
    ENERGIES, 2024, 17 (22)
  • [22] Robust Load Frequency Control in Multi-Area Power System: An LMI Approach
    Ahammad, Fakir Uddin Ali
    Mandal, Sharmistha
    2016 IEEE FIRST INTERNATIONAL CONFERENCE ON CONTROL, MEASUREMENT AND INSTRUMENTATION (CMI), 2016, : 136 - 140
  • [23] Load-frequency control in a multi-source power system connected to wind farms through multi terminal HVDC systems
    Tavakoli, Mehdi
    Pouresmaeil, Edris
    Adabi, Jafar
    Godina, Radu
    Catalao, Joao P. S.
    COMPUTERS & OPERATIONS RESEARCH, 2018, 96 : 305 - 315
  • [24] Analysis of PID controller for the load frequency control of static synchronous series compensator and capacitive energy storage source-based multi-area multi-source interconnected power system with HVDC link
    Khadanga, Rajendra Kumar
    Kumar, Amit
    INTERNATIONAL JOURNAL OF BIO-INSPIRED COMPUTATION, 2019, 13 (02) : 131 - 139
  • [25] Load frequency control of Multi-area Power System in Deregulated Environment
    Keerthana, J.
    Selvi, K.
    2018 NATIONAL POWER ENGINEERING CONFERENCE (NPEC), 2018,
  • [26] Decentralized adaptive load frequency control in a multi-area power system
    Menniti, D
    Pinnarelli, A
    Scordino, N
    Sorrentino, N
    LARGE SCALE SYSTEMS: THEORY AND APPLICATIONS 2001 (LSS'01), 2001, : 157 - 163
  • [27] Multi-Area Load Frequency Control in Power System Integrated With Wind Farms Using Fuzzy Generalized Predictive Control Method
    Wang, Huimin
    Li, Zhaojun Steven
    IEEE TRANSACTIONS ON RELIABILITY, 2023, 72 (02) : 737 - 747
  • [28] Comparative Performance Assessment of Different Energy Storage Devices in Combined LFC and AVR Analysis of Multi-Area Power System
    Kalyan, CH. Naga Sai
    Goud, B. Srikanth
    Reddy, Ch. Rami
    Bajaj, Mohit
    Sharma, Naveen Kumar
    Alhelou, Hassan Haes
    Siano, Pierluigi
    Kamel, Salah
    ENERGIES, 2022, 15 (02)
  • [29] Performance Enhancement of Multi-Area Interconnected Power System using Revolutionary Energy Balance Control
    Ayyappan, B. Prakash
    Kanimozhi, R.
    CONTROL ENGINEERING AND APPLIED INFORMATICS, 2022, 24 (03): : 50 - 63
  • [30] Robust load frequency control of multi-area interconnected power system with time delay
    Zhao, Xuemao
    Sun, Yonghui
    Yuan, Chao
    Wei, Zhinong
    Sun, Guoqiang
    2015 34TH CHINESE CONTROL CONFERENCE (CCC), 2015, : 8969 - 8974