Seismic behaviour of Concrete-filled steel tubular column to H-Shape steel beam connection with side plate

被引:4
|
作者
Dong, Xitong [1 ,2 ,3 ]
Wang, Lai [1 ,2 ]
Xu, Zhifeng [1 ,2 ]
Guan, Shangshang [1 ,2 ]
Liu, Liyuan [1 ,2 ]
Chen, Haitao [1 ,2 ]
机构
[1] Shandong Univ Sci & Technol, Coll Civil Engn & Architecture, Qingdao 266590, Peoples R China
[2] Shandong Univ Sci & Technol, Shandong Key Lab Civil Engn Disaster Prevent & Mit, Qingdao 266590, Peoples R China
[3] Tianyuan Construct Grp Co Ltd, Linyi 276000, Peoples R China
基金
中国国家自然科学基金;
关键词
CFST column; Side plate connection; Reversed cyclic loading test; Seismic behaviour; Mechanism analysis;
D O I
10.1016/j.istruc.2023.02.089
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To ensure the quality of filled concrete and improve the indoor utilization rate of steel frame structure residential buildings, a novel concrete-filled steel tubular (CFST) column to H-shape steel beam connection with side plate was proposed in this study. Six specimens of 1/3 scale were tested under reversed cyclic loading. To evaluate the hysteretic performance, failure mode, ductility, stiffness degradation, strength degradation and energy dissipa-tion capacity. The evaluation parameters include the axial load ratio, and the side plate height and thickness. The results indicated that the failure mode mainly exhibited the steel beam buckling failure, making all hysteretic curves exhibit typically spindle-shaped. The equivalent viscous damping coefficient is 0.305-0.394. The average story drift angle at the ultimate stage is 1/31 similar to 1/37. It shows that all connections possess sufficient energy dissipation capacity and excellent ductility. The peak and ultimate load are significantly reduced with the in-crease of the axial load ratio. And the secant stiffness increases in the elastic stage with the rise of the thickness and height of the side plate. Finally, the failure mode, hysteresis curve, and envelope curve achieved from the finite element method(FEM) established in this paper are consistent with the test results. And the FEM disclosed that the beam flange stress is transferred to the side plate through the fillet weld, and the side plate stress is transferred to the column panel through the fillet weld.
引用
收藏
页码:1608 / 1624
页数:17
相关论文
共 50 条
  • [41] Seismic behaviour of novel concrete-filled composite plate shear walls with boundary columns
    Yan, Jia-Bao
    Hu, Hui-Tao
    Wang, Tao
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 179 (179)
  • [42] Effects of boundary restraints on concrete-filled steel tubular columns with reinforcements exposed to fire
    Guo, Zhen
    Wang, Xing
    Zhang, Xuecheng
    Song, Jun
    Li, Chenfeng
    THIN-WALLED STRUCTURES, 2019, 142 : 52 - 63
  • [43] Compressive behaviour of concrete-filled steel tubular stub columns subjected to freeze-thaw cycles and sustained load combinations
    Li, Wei
    Li, Xin-Yi
    ENGINEERING STRUCTURES, 2025, 328
  • [44] Axial compressive behavior of recycled ceramic coarse aggregate concrete-filled steel tubular columns
    Wang, Yi
    Huang, Hong
    Zeng, Jiantao
    Hu, Wenbin
    Cheng, Yingyao
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 210
  • [45] ANFIS-Based Accurate Estimation of the Confinement Effect for Concrete-Filled Steel Tubular (CFST)
    S. Balasubramanian
    J. Jegan
    M. C. Sundarraja
    International Journal of Fuzzy Systems, 2020, 22 : 1760 - 1771
  • [46] Research on special-shaped concrete-filled steel tubular columns under axial compression
    Liu, Xianggang
    Xu, Chuangze
    Liu, Jiepeng
    Yang, Yuanlong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 147 : 203 - 223
  • [47] ANFIS-Based Accurate Estimation of the Confinement Effect for Concrete-Filled Steel Tubular (CFST)
    Balasubramanian, S.
    Jegan, J.
    Sundarraja, M. C.
    INTERNATIONAL JOURNAL OF FUZZY SYSTEMS, 2020, 22 (06) : 1760 - 1771
  • [48] Experimental Investigations on Axial–Flexural Behaviour of Slender Concrete Filled Steel Tubular Columns
    Garg V.
    Patel A.J.
    Purohit S.
    Journal of The Institution of Engineers (India): Series A, 2022, 103 (04) : 1089 - 1100
  • [49] Fire resistant behavior of concrete-filled steel tubular columns with square cross-sections under three-side fire
    Yang Hua
    Zhang Sumei
    Ranzi, Gianluca
    8TH INTERNATIONAL CONFERENCE ON STEEL-CONCRETE COMPOSITE AND HYBRID STRUCTURES, PROCEEDINGS, 2006, : 845 - 852
  • [50] An innovative multi-objective optimization approach for compact concrete-filled steel tubular (CFST) column design utilizing lightweight high-strength concrete
    Faridmehr I.
    Nehdi M.L.
    Nejad A.F.
    Sahraei M.A.
    Kamyab H.
    Valerievich K.A.
    International Journal of Lightweight Materials and Manufacture, 2024, 7 (03) : 405 - 425