Absolute calibration of the spectral sensitivity of an x-ray streak camera over the 0.1-10 keV spectral range equipped with CsI photocathode

被引:1
|
作者
Hubert, S. [1 ]
Boubault, F. [1 ]
机构
[1] CEA, CESTA, F-33116 Le Barp, France
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2023年 / 94卷 / 11期
关键词
CHARGE-COUPLED-DEVICE; DOUBLE-CRYSTAL MONOCHROMATOR; GRAZING-INCIDENCE; SYNCHROTRON; RADIOMETRY; GENERATOR; FACILITY; DETECTOR;
D O I
10.1063/5.0156102
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, we report the absolute measurement of the spectral sensitivity of a bilamellar tube x-ray streak camera (XRSC) over the 0.1-10 keV range equipped with a CsI photocathode for Laser MegaJoule (LMJ) fusion experiments. This calibration of the XRSC is performed in static mode by using two multi-anode x-ray generators. Two silicon drift detectors (SDDs) previously calibrated at the Physikalisch-Technische-Bundesanstalt radiometric laboratory are used as secondary standards. Both x-ray generators work with a specific monochromator for radiometric measurements. In the sub-keV region, a 1 m-grazing incidence Rowland geometry monochromator specifically developed to handle LMJ's x-ray camera is used, whereas for higher energies (>2 keV), a double-crystal monochromator is employed. The absolute spectral sensitivity of the XRSC is obtained by comparing the CCD counts of the XRSC output with the output counts in x-ray lines recorded by the SDD. The results obtained below 1.2 keV are, to our knowledge, the first measurements of the spectral sensitivity of an XRSC in the soft x-ray range with a CsI photocathode. Comparison with a model describing the spectral dependence of the sensitivity of the XRSC revealed that measurements obtained in the sub-keV region are greater than expected, whereas they agree with the model above 4.5 keV. There may be several contributors to this behavior, including the grain morphology of the CsI layer and exposure to air.
引用
收藏
页数:10
相关论文
共 45 条
  • [21] A Technique for Registration of Absolute Fluxes of X-Ray Laser Plasma Radiation in the 0.15-1.0 keV Spectral Range with the Spectral λ/Δλ ≈ 20 and 30 ps Time Resolutions
    Muntyan, A. N.
    Petrov, S., I
    Romanova, N. M.
    Sankin, E., V
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2021, 64 (02) : 230 - 233
  • [22] Study of laser plasmas as X-ray sources in the 1-10 keV spectral region
    Bastiani, S.
    Giulietti, A.
    Gizzi, L.A.
    Ceccotti, T.
    Macchi, A.
    Giulietti, D.
    Laser and Particle Beams, 1995, 13 (04)
  • [23] A study of laser plasmas as X-ray sources in the 1-10 keV spectral region
    Bastiani, S
    Giulietti, D
    Giulietti, A
    Gizzi, LA
    Ceccotti, T
    Macchi, A
    LASER AND PARTICLE BEAMS, 1995, 13 (04) : 493 - 501
  • [24] A STUDY OF LASER PLASMAS AS X-RAY SOURCES IN THE 1-10 KEV SPECTRAL REGION
    BASTIANI, S
    GIULIETTI, D
    GIULIETTI, A
    GIZZI, LA
    CECCOTTI, T
    MACCHI, A
    LASER INTERACTION WITH MATTER, 1995, (140): : 101 - 104
  • [25] Precise Calibration and Application of Hard X-Ray Detector in Energy Range of 10-100 keV
    He Xiaoan
    Yi Rongqing
    Li Chaoguang
    Chen Bolun
    Li Fan
    Zheng Jianhua
    Xue Yanlin
    Wang Feng
    ACTA OPTICA SINICA, 2022, 42 (11)
  • [26] Spectral responsivity of silicon photodiodes: High-accuracy measurement and improved self calibration in the soft X-ray spectral range
    Scholze, F
    Rabus, H
    Ulm, G
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VII, 1996, 2808 : 534 - 543
  • [27] Relative efficiency calibration between two silicon drift detectors performed with a monochromatized X-ray generator over the 0.1-1.5 keV range
    Hubert, S.
    Boubault, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 884 : 70 - 74
  • [28] The x-ray calibration facility of the laser integration line in the 0.9-10 keV range: The high energy x-ray source and some applications
    Hubert, S.
    Dubois, J. L.
    Gontier, D.
    Lidove, G.
    Reverdin, C.
    Soullie, G.
    Stemmler, P.
    Villette, B.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (05):
  • [29] Recording of the space-time structure of Z-pinch x-ray radiation in the spectral range of 0.2-10 kev.
    Petrov, SI
    Lazarchuk, VP
    Murugov, VM
    Senik, AV
    Afonin, VI
    Berkovskii, AG
    Gubanov, YI
    Pryanishnikov, IG
    Kislitskaya, GN
    22ND INTERNATIONAL CONGRESS ON HIGH-SPEED PHOTOGRAPHY AND PHOTONICS, 1997, 2869 : 773 - 778
  • [30] MEASURING THE ABSOLUTE SENSITIVITY OF AN X-RAY ELECTRON-OPTICAL IMAGE CONVERTER IN THE RANGE 7-20 KEV
    DOLBNYA, IP
    KNYAZEV, BA
    SIMONOV, VP
    FELDMAN, GG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 308 (1-2): : 435 - 437