Enhanced low-dose x-ray sensing nature of nanocrystalline CaWO4 sensor

被引:1
|
作者
Karthieka, R. R. [1 ]
Anil, Mayaha Elsa [2 ]
Prakash, T. [1 ]
机构
[1] Univ Madras, Natl Ctr Nanosci & Nanotechnol, Guindy Campus, Chennai 600025, Tamilnadu, India
[2] Womens Christian Coll, Postgrad Dept Phys, Coll Rd, Chennai 600006, Tamil Nadu, India
关键词
Low dose X-ray sensor; High attenuating material; Nanocrystalline thick film; X-ray instigated photocurrent; Applied bias; PERFORMANCE; SUBSTRATE;
D O I
10.1016/j.sna.2023.114200
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Extensive research on the development of superior sensitive X-ray sensors by many researchers is due to their increased demand in numerous fields, like medical radiography, security inspection, and scientific research areas. Especially in healthcare, repeated or long-term high-dose X-ray exposure on patients may cause serious health hazards. Therefore, developing a superior sensing low dose X-ray sensor is essential. In this present work, a nanocrystalline CaWO4 thick film above an interdigitated electrode was developed as a direct conversion X-ray sensor that operates at different low doses (mGy) using an intraoral pulsed X-ray (70 keV) machine. The X-ray instigated photocurrent of nano-CaWO4 thick film was examined under different applied bias to obtain superior sensitivity of the device. The nano-CaWO4 thick film exhibit sensitivity of 10 nC/mGycm3 at 0.20 mGy (0.06 s) low dose under 5 V applied bias. A suitable mechanism was proposed to explain the nano-CaWO4 thick film sensing behaviour at different biased conditions.
引用
收藏
页数:7
相关论文
共 28 条
  • [1] Fabrication of nanocrystalline Ga2O3-NiO heterojunctions for large-area low-dose X-ray imaging
    Zhang, Zhipeng
    Chen, Manni
    Zhan, Runze
    Chen, Huanjun
    Wang, Kai
    Deng, Shaozhi
    Chen, Jun
    APPLIED SURFACE SCIENCE, 2022, 604
  • [2] Luminescence efficiency of calcium tungstate (CaWO4) under X-ray radiation: Comparison with Gd2O2S:Tb
    Michail, C.
    Valais, I.
    Fountos, G.
    Bakas, A.
    Fountzoula, C.
    Kalyvas, N.
    Karabotsos, A.
    Sianoudis, I.
    Kandarakis, I.
    MEASUREMENT, 2018, 120 : 213 - 220
  • [3] Influence of grain size on direct conversion X-ray sensing Bi2O3 for low-dose X-rays
    Karthieka, R. R.
    Prakash, T.
    MATERIALS SCIENCE IN SEMICONDUCTOR PROCESSING, 2023, 157
  • [4] Nanocomposite thick films of CsPbI3: PVDF-HFP on plastics for direct conversion low-dose X-ray sensor
    Karthieka, R. R.
    Venkatasubbu, G. Devanand
    Prakash, T.
    MATERIALS SCIENCE IN SEMICONDUCTOR PROCESSING, 2020, 120
  • [5] Low-dose real-time X-ray imaging with nontoxic double perovskite scintillators
    Zhu, Wenjuan
    Ma, Wenbo
    Su, Yirong
    Chen, Zeng
    Chen, Xinya
    Ma, Yaoguang
    Bai, Lizhong
    Xiao, Wenge
    Liu, Tianyu
    Zhu, Haiming
    Liu, Xiaofeng
    Liu, Huafeng
    Liu, Xu
    Yang, Yang
    LIGHT-SCIENCE & APPLICATIONS, 2020, 9 (01)
  • [6] Data-driven estimation of noise variance stabilization parameters for low-dose x-ray images
    Hariharan, Sai Gokul
    Strobel, Norbert
    Kaethner, Christian
    Kowarschik, Markus
    Fahrig, Rebecca
    Navab, Nassir
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (22)
  • [7] Low Dose Digital X-ray Imaging With Avalanche Amorphous Selenium
    Scheuermann, James R.
    Goldan, Amir H.
    Tousignant, Olivier
    Leveille, Sebastien
    Zhao, Wei
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [8] Low-Dose X-ray Activation of W(VI)-Doped Persistent Luminescence Nanoparticles for Deep-Tissue Photodynamic Therapy
    Song, Liang
    Li, Pei-Pei
    Yang, Wen
    Lin, Xia-Hui
    Liang, Hong
    Chen, Xiao-Feng
    Liu, Gang
    Li, Juan
    Yang, Huang-Hao
    ADVANCED FUNCTIONAL MATERIALS, 2018, 28 (18)
  • [9] A Numerical Study of an Amorphous Silicon Dual-Gate Photo Thin-Film Transistor for Low-Dose X-Ray Imaging
    Wang, Luting
    Ou, Hai
    Chen, Jun
    Wang, Kai
    JOURNAL OF DISPLAY TECHNOLOGY, 2015, 11 (08): : 646 - 651
  • [10] High-resolution, low-dose phase contrast X-ray tomography for 3D diagnosis of human breast cancers
    Zhao, Yunzhe
    Brun, Emmanuel
    Coan, Paola
    Huang, Zhifeng
    Sztrokay, Aniko
    Diemoz, Paul Claude
    Liebhardt, Susanne
    Mittone, Alberto
    Gasilov, Sergei
    Miao, Jianwei
    Bravin, Alberto
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2012, 109 (45) : 18290 - 18294