Fluorescent Aptasensor for Determination of 8-Oxo-2?- deoxyguanosine in Urine Using Carbon Dots and Amine- Functionalized Gold Nanoparticles

被引:1
|
作者
Ngernpimai, Sawinee [1 ,2 ]
Thonghlueng, Janpen [3 ]
Phothikul, Yaowaret [1 ]
Chompoosor, Apiwat [4 ]
Thanan, Raynoo [1 ]
Puangmali, Theerapong [3 ]
Sakonsinsiri, Chadamas [1 ]
机构
[1] Khon Kaen Univ, Fac Med, Dept Biochem, Khon Kaen 40002, Thailand
[2] Khon Kaen Univ, Fac Associated Med Sci, Ctr Innovat & Stand Med Technol & Phys Therapy, Khon Kaen 40002, Thailand
[3] Khon Kaen Univ, Fac Sci, Dept Phys, Khon Kaen 40002, Thailand
[4] Ramkhamhang Univ, Fac Sci, Dept Chem, Bangkok 10240, Thailand
关键词
8-oxo-dG; fluorescence; gold nanoparticle; carbon dot; aptasensor; OXIDATIVE STRESS; COLORIMETRIC DETECTION; DNA-DAMAGE; 8-HYDROXY-2'-DEOXYGUANOSINE; APTAMER; MECHANISM; DEVICE; ASSAY;
D O I
10.1021/acsanm.3c01238
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
8-Oxo-7,8-dihydro-2 '-deoxyguanosine (8-oxo-dG) is a crucial biomarker of oxidative DNA damage. Herein, a highly sensitive fluorescent aptasensor for detecting 8-oxo-dG in urine was developed based on aptamer-mediated quenching of amino-terminated oligo(ethylene glycol)-capped gold nanoparticles (NH2-TEG-AuNPs) toward green emissive carbon dots (G -CDs). G-CDs were employed as fluorometric reporters. Upon addition of 8-oxo-dG, it formed a complex with an anti-8-oxo-dG aptamer, resulting in the quenching of fluorescence as NH2-TEG-AuNPs absorbed the emission from G-CDs. Initially, NH2-TEG-AuNPs suppressed the fluorescence intensity of G-CDs via the inner-filter effect (IFE). With the addition of the aptamers to a mixture of G-CDs and NH2-TEG-AuNPs, the electrostatic interactions between the aptamer and NH2-TEG-AuNPs resulted in the aggregation of NH2-TEG-AuNPs and the recovery of the fluorescence intensity of the quenched G-CDs. NH2-TEG-AuNPs dispersed due to the high affinity between the aptamer and 8-oxo-dG molecules, and the system demonstrated a fluorescence '' turn-off '' response of G-CDs. Thus, it was possible to determine the 8-oxo-dG concentration. A fluorescence calibration curve was constructed with two linear ranges: 100-2000 and 2000-10,000 nM. The limit of detection (LOD) for 8-oxo-dG was 15.89 nM. This approach was successfully applied to assess 8-oxo-dG in synthetic urine samples with mean recoveries ranging from 99 to 120% and relative standard deviations (RSDs) between 1.1 and 4.1%. The analytical performance was comparable to a commercially available enzyme-linked immunosorbent assay (ELISA) kit. This proposed fluorescent aptasensor for 8-oxo-dG detection in urine exhibited high selectivity and sensitivity over a broad concentration range against the target molecule and has the potential to be developed as a new platform for rapid screening of 8-oxo-dG.
引用
收藏
页码:7055 / 7064
页数:10
相关论文
共 35 条
  • [31] Simultaneous determination of O6-methyl-2′-deoxyguanosine, 8-oxo-7,8-dihydro-2′-deoxyguanosine, and 1,N6-etheno-2′-deoxyadenosine in DNA using on-line sample preparation by HPLC column switching coupled to ESI-MS/MS
    Brink, A
    Lutz, U
    Völkel, W
    Lutz, WK
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 830 (02): : 255 - 261
  • [32] An Electrochemical Impedance Spectroscopy-Based Aptasensor for the Determination of SARS-CoV-2-RBD Using a Carbon Nanofiber-Gold Nanocomposite Modified Screen-Printed Electrode
    Tabrizi, Mahmoud Amouzadeh
    Acedo, Pablo
    BIOSENSORS-BASEL, 2022, 12 (03):
  • [33] Highly sensitive and efficient voltammetric method for the determination of 4-aminophenol in paracetamol tablet and urine samples using screen printed carbon electrode modified with humic acid functionalized iron oxide nanoparticles
    Niaz, Abdul
    Arain, Muhammad Balal
    Soylak, Mustafa
    INORGANIC CHEMISTRY COMMUNICATIONS, 2025, 174
  • [34] The selective capture of Pb2+ in rice phloem sap using glutathione-functionalized gold nanoparticles/multi-walled carbon nanotubes: enhancing anti-interference electrochemical detection
    Jiang, Min
    Chen, Hui-Ru
    Li, Shan-Shan
    Liang, Rui
    Liu, Jin-Huai
    Yang, Yang
    Wu, Yue-Jin
    Yang, Meng
    Huang, Xing-Jiu
    ENVIRONMENTAL SCIENCE-NANO, 2018, 5 (11) : 2761 - 2771
  • [35] An Optimized Electrochemical Methodology by Box-Behnken Design for Non-Enzymatic Determination of Uric Acid in Urine Samples Using a Bi2O3 Nanoparticles-Carbon Paste Electrode
    Hernandez-Ramirez, Daniel
    Mendoza-Huizar, Luis Humberto
    Galan-Vidal, Carlos Andres
    Aguilar-Lira, Guadalupe Yoselin
    Rebolledo-Perales, Luz Elena
    Alvarez-Romero, Giaan Arturo
    JOURNAL OF ANALYTICAL CHEMISTRY, 2023, 78 (11) : 1557 - 1565