Conventional and contrast-enhanced ultrasound in the differential diagnosis of recurrent dermatofibrosarcoma protuberans and postoperative scar

被引:4
作者
Gong, Xia [1 ]
Li, Jia [1 ]
Ding, Angang [1 ]
Zuo, Jiaxin [1 ]
Rao, Yamin [2 ]
Chen, Jun [3 ]
Xiong, Ping [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Sch Med, Dept Ultrasound, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Sch Med, Dept Pathol, Shanghai, Peoples R China
[3] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Dept Dermatol & Dermatol Surg, Sch Med, Shanghai, Peoples R China
关键词
Contrast-enhanced ultrasound; Conventional ultrasound; Color Doppler; Postoperative scar; Recurrent dermatofibrosarcoma protuberans; BREAST-CANCER; SONOGRAPHY; UPDATE;
D O I
10.1186/s12885-024-11991-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background Dermatofibrosarcoma protuberans (DFSP) has a high recurrence rate after resection. Because of the lack of specific manifestations, recurrent DFSP is easily misdiagnosed as post-resection scar. A few series have reported ultrasound findings of recurrent DFSP; moreover, the usefulness of contrast-enhanced ultrasound in differentiating recurrent DFSP has not been studied. Objective We investigated conventional and contrast-enhanced ultrasound in the differential diagnosis of recurrent DFSP and post-resection scar. Methods We retrospectively evaluated the findings of conventional and contrast-enhanced ultrasound in 34 cases of recurrent DFSP and 38 postoperative scars examined between January 2018 and December 2022. Results The depth and vascular density of recurrent DFSP were greater than those of postoperative scars (P < 0.05). On gray-scale ultrasound, recurrent DFSP lesions were more commonly irregular, heterogeneous, and hypoechoic, with finger-like projections and ill-defined borders. Postoperative scar was more likely to appear as hypoechoic and homogeneous with well-defined borders (P < 0.05). On color Doppler ultrasound, recurrent DFSP was more likely to feature rich arterial and venous blood flow, and postoperative scar was more likely to display poor blood flow (P < 0.05). On contrast-enhanced ultrasound, recurrent DFSP was more likely to feature heterogeneous hyper-enhancement, and postoperative scar was more likely to display homogeneous iso-enhancement (P < 0.05). Recurrent DFSP presented a higher peak and sharpness than postoperative scar (P < 0.05). Conclusion Conventional and contrast-enhanced ultrasound produced distinct features of recurrent DFSP and post-resection scar, which could improve the accuracy of differential diagnosis.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Conventional and contrast-enhanced ultrasound in the differential diagnosis of recurrent dermatofibrosarcoma protuberans and postoperative scar
    Xia Gong
    Jia Li
    Angang Ding
    Jiaxin Zuo
    Yamin Rao
    Jun Chen
    Ping Xiong
    BMC Cancer, 24
  • [2] Accuracy of contrast-enhanced ultrasound compared with conventional ultrasound in acute pancreatitis: Diagnosis and complication monitoring
    Cai, Diming
    Parajuly, Shyam Sundar
    Wang, Huiyao
    Wang, Xiaoling
    Ling, Wenwu
    Song, Bin
    Li, Yongzhong
    Luo, Yan
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2016, 12 (05) : 3189 - 3194
  • [3] Value of Contrast-Enhanced Ultrasound in the Differential Diagnosis of Focal Splenic Lesions
    Yang, Rui
    Lu, Qiang
    Xu, Jinshun
    Huang, Jiayan
    Gao, Binyang
    Zhang, Huan
    Zhou, Jie
    Du, Lanxin
    Yan, Feng
    CANCER MANAGEMENT AND RESEARCH, 2021, 13 : 2947 - 2958
  • [4] Application of contrast-enhanced ultrasound in the diagnosis of solid pancreatic lesions-A comparison of conventional ultrasound and contrast-enhanced CT
    Fan, Zhihui
    Li, Ying
    Yan, Kun
    Wu, Wei
    Yin, Shanshan
    Yang, Wei
    Xing, Baocai
    Li, Xiaoting
    Zhang, Xiaopeng
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (09) : 1385 - 1390
  • [5] Improving precision of resection by pre-surgery inspections with contrast-enhanced ultrasound for dermatofibrosarcoma protuberans
    Ma, Chuan
    Sun, Yang
    Yang, Xin
    Zhang, Qian
    Zhang, Chunlei
    Cui, Ligang
    DERMATOLOGIC THERAPY, 2016, 29 (06) : 473 - 475
  • [6] The application of contrast-enhanced ultrasound in the diagnosis of cesarean scar pregnancies
    Li, Hui-Dong
    Zhang, Zhi-Kun
    Guo, Shuang
    Qu, Peng-Peng
    CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 2018, 45 (05) : 731 - 734
  • [7] The Value of Contrast-Enhanced Ultrasound in the Diagnosis of Cesarean Scar Pregnancy
    Xiong, Xi
    Yan, Ping
    Gao, Chunyan
    Sun, Qiulei
    Xu, Fenglian
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [8] value of contrast-enhanced ultrasound in the differential diagnosis of gallbladder lesion
    Hui-Ping Zhang
    Min Bai
    Ji-Ying Gu
    Ying-Qian He
    Xiao-Hui Qiao
    Lian-Fang Du
    World Journal of Gastroenterology, 2018, (06) : 744 - 751
  • [9] Value of contrast-enhanced ultrasound in the differential diagnosis of gallbladder lesion
    Zhang, Hui-Ping
    Bai, Min
    Gu, Ji-Ying
    He, Ying-Qian
    Qiao, Xiao-Hui
    Du, Lian-Fang
    WORLD JOURNAL OF GASTROENTEROLOGY, 2018, 24 (06) : 744 - 751
  • [10] Conventional ultrasound and contrast-enhanced ultrasound radiomics in breast cancer and molecular subtype diagnosis
    Gong, Xuantong
    Li, Qingfeng
    Gu, Lishuang
    Chen, Chen
    Liu, Xuefeng
    Zhang, Xuan
    Wang, Bo
    Sun, Chao
    Yang, Di
    Li, Lin
    Wang, Yong
    FRONTIERS IN ONCOLOGY, 2023, 13