Multi-instance learning based lung nodule system for assessment of CT quality after small-field-of-view reconstruction

被引:0
|
作者
Ma, Yanqing [1 ]
Cao, Hanbo [1 ]
Li, Jie [1 ]
Lin, Mu [2 ]
Gong, Xiangyang [1 ]
Lin, Yi [1 ]
机构
[1] Hangzhou Med Coll, Zhejiang Prov Peoples Hosp, Affiliated Peoples Hosp, Dept Radiol, Hangzhou 310014, Zhejiang, Peoples R China
[2] Infervis Technol Co Ltd, Beijing 100010, Peoples R China
关键词
Computed tomography; Small-field-of-view; Multi-instance learning; Contrast-to-noise ratio; WEIGHTED IMAGING DWI; COMPUTED-TOMOGRAPHY; CAD;
D O I
10.1038/s41598-024-53797-4
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Small-field-of-view reconstruction CT images (sFOV-CT) increase the pixel density across airway structures and reduce partial volume effects. Multi-instance learning (MIL) is proposed as a weakly supervised machine learning method, which can automatically assess the image quality. The aim of this study was to evaluate the disparities between conventional CT (c-CT) and sFOV-CT images using a lung nodule system based on MIL and assessments from radiologists. 112 patients who underwent chest CT were retrospectively enrolled in this study between July 2021 to March 2022. After undergoing c-CT examinations, sFOV-CT images with small-field-of-view were reconstructed. Two radiologists analyzed all c-CT and sFOV-CT images, including features such as location, nodule type, size, CT values, and shape signs. Then, an MIL-based lung nodule system objectively analyzed the c-CT (c-MIL) and sFOV-CT (sFOV-MIL) to explore their differences. The signal-to-noise ratio of lungs (SNR-lung) and contrast-to-noise ratio of nodules (CNR-nodule) were calculated to evaluate the quality of CT images from another perspective. The subjective evaluation by radiologists showed that feature of minimal CT value (p = 0.019) had statistical significance between c-CT and sFOV-CT. However, most features (all with p < 0.05), except for nodule type, location, volume, mean CT value, and vacuole sign (p = 0.056-1.000), had statistical differences between c-MIL and sFOV-MIL by MIL system. The SNR-lung between c-CT and sFOV-CT had no statistical significance, while the CNR-nodule showed statistical difference (p = 0.007), and the CNR of sFOV-CT was higher than that of c-CT. In detecting the difference between c-CT and sFOV-CT, features extracted by the MIL system had more statistical differences than those evaluated by radiologists. The image quality of those two CT images was different, and the CNR-nodule of sFOV-CT was higher than that of c-CT.
引用
收藏
页数:8
相关论文
共 13 条
  • [1] Multi-instance learning based lung nodule system for assessment of CT quality after small-field-of-view reconstruction
    Yanqing Ma
    Hanbo Cao
    Jie Li
    Mu Lin
    Xiangyang Gong
    Yi Lin
    Scientific Reports, 14
  • [2] Multi-View Multi-Instance Learning Based on Joint Sparse Representation and Multi-View Dictionary Learning
    Li, Bing
    Yuan, Chunfeng
    Xiong, Weihua
    Hu, Weiming
    Peng, Houwen
    Ding, Xinmiao
    Maybank, Steve
    IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2017, 39 (12) : 2554 - 2560
  • [3] Effect of CT reconstruction settings on the performance of a deep learning based lung nodule CAD system
    Blazis, Stephan P.
    Dickerscheid, Dennis B. M.
    Linsen, Philip V. M.
    Jarnalo, Carine O. Martins
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 136
  • [4] Synergistic learning of lung lobe segmentation and hierarchical multi-instance classification for automated severity assessment of COVID-19 in CT images
    He, Kelei
    Zhao, Wei
    Xie, Xingzhi
    Ji, Wen
    Liu, Mingxia
    Tang, Zhenyu
    Shi, Yinghuan
    Shi, Feng
    Gao, Yang
    Liu, Jun
    Zhang, Junfeng
    Shen, Dinggang
    PATTERN RECOGNITION, 2021, 113
  • [5] Lung cancer subtype classification using histopathological images based on weakly supervised multi-instance learning
    Zhao, Lu
    Xu, Xiaowei
    Hou, Runping
    Zhao, Wangyuan
    Zhong, Hai
    Teng, Haohua
    Han, Yuchen
    Fu, Xiaolong
    Sun, Jianqi
    Zhao, Jun
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (23)
  • [6] Deep Learning-Based Reconstruction Algorithm With Lung Enhancement Filter for Chest CT: Effect on Image Quality and Ground Glass Nodule Sharpness
    Hwang, Min-Hee
    Kang, Shinhyung
    Lee, Ji Won
    Lee, Geewon
    KOREAN JOURNAL OF RADIOLOGY, 2024, 25 (09) : 833 - 842
  • [7] Design of Automatic Lung Nodule Detection System Based on Multi-Scene Deep Learning Framework
    Zhang, Qinghai
    Kong, Xiaojing
    IEEE ACCESS, 2020, 8 : 90380 - 90389
  • [8] Transformer as a Spatially Aware Multi-instance Learning Framework to Predict the Risk of Death for Early-stage Non-small Cell Lung Cancer
    Zhou, Yufei
    Koyuncu, Can
    Barrera, Cristian
    Corredor, German
    Wang, Xiangxue
    Lu, Cheng
    Madabhushi, Anant
    MEDICAL IMAGING 2023, 2023, 12471
  • [9] CZT-based photon-counting-detector CT with deep-learning reconstruction: image quality and diagnostic confidence for lung tumor assessment
    Sasaki, Tomoaki
    Kuno, Hirofumi
    Nomura, Keiichi
    Muramatsu, Yoshihisa
    Aokage, Keiju
    Samejima, Joji
    Taki, Tetsuro
    Goto, Eisuke
    Wakabayashi, Masashi
    Furuya, Hideki
    Taguchi, Hiroki
    Kobayashi, Tatsushi
    JAPANESE JOURNAL OF RADIOLOGY, 2025,
  • [10] Deep learning-based image domain reconstruction enhances image quality and pulmonary nodule detection in ultralow-dose CT with adaptive statistical iterative reconstruction-V
    Ye, Kai
    Xu, Libo
    Pan, Boyang
    Li, Jie
    Li, Meijiao
    Yuan, Huishu
    Gong, Nan-Jie
    EUROPEAN RADIOLOGY, 2025,