Development of a Novel Control Scheme to Achieve the Minimum Unbalance Factor and Real Power Fluctuations under Asymmetrical Faults

被引:1
作者
Abubakar, Muhammad [1 ]
Renner, Herwig [1 ]
Schuerhuber, Robert [1 ]
机构
[1] Graz Univ Technol, Inst Elect Power Syst, Inffeldgasse 18, A-8010 Graz, Austria
关键词
grid-tide converters; asymmetrical faults; minimum unbalanced factor; low-voltage ride-through; recent grid codes; minimum real power fluctuations; IMPLEMENTATION; CANCELLATION;
D O I
10.3390/en16227511
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The increasing share of converter-based renewable energy sources in the power system has forced the system operators to demand voltage support from the converters in case of faults. In the case of symmetric faults, all the phases have equal voltage support, but in the case of asymmetric faults, selective voltage support is required. The grid codes define the voltage support required in the case of symmetric/asymmetric faults, which is the reactive current injection in the respective sequence proportional to its voltage dip, but studies confirm that it does not result in a minimum unbalance factor in the case of asymmetric faults. The unbalance factor is an indication of the level of imbalance voltage among the phases. Moreover, it also results in fluctuated active power injection in the case of asymmetric faults, which causes dc link voltage fluctuations, and the power reversal may also occur due to such fluctuations, which leads to higher protection costs for the dc link. In order to (1) enhance the uniformity of voltage among different phases in the case of asymmetric faults and (2) minimize the real power fluctuations in such conditions, a novel control scheme is presented in this paper. It optimally distributes the negative sequence current phasor into its active and reactive components to achieve the minimum voltage unbalance factor. It also confirms the minimum real power fluctuations by adjusting the positive and negative sequence current phasors. The proposed scheme also ensures the current limit of the converter. The proposed scheme is developed in Matlab/Simulink and tested under different faulty conditions. The results confirm the better performance of the proposed scheme against the grid code recommendation under different faulty conditions.
引用
收藏
页数:22
相关论文
共 29 条
  • [1] Aboelsaud R., 2019, Int. J. Power Electron. Drive Syst. (IJPEDS), V10, P242, DOI [10.11591/ijpeds.v10.i1.pp242-255, DOI 10.11591/IJPEDS.V10.I1.PP242-255]
  • [2] Abubakar M., 2023, P CIGRE B4 C 2023
  • [3] Abubakar M., 2022, P 2 INT C SUST MOB A, P1
  • [4] Development of a Novel Control Scheme for Grid-Following Converter under Asymmetrical Faults
    Abubakar, Muhammad
    Renner, Herwig
    Schurhuber, Robert
    [J]. ENERGIES, 2023, 16 (03)
  • [5] Phasor-domain Dynamic Model of Asymmetric Current Injection Controller for Converter-interfaced Generator
    Almeida, Victor A. F.
    Taranto, Glauco N.
    Marinho, Jose M. T.
    [J]. JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2021, 9 (06) : 1269 - 1278
  • [6] [Anonymous], 2018, VDE-AR-N 4110
  • [7] [Anonymous], 2000, Understanding Power Quality Problems
  • [8] Azevedo G., 2011, Eletronica Potencia, V16, P296, DOI [10.18618/REP.20114.296303, DOI 10.18618/REP.20114.296303]
  • [9] Positive-Sequence Voltage Control, Full Negative-Sequence Cancellation, and Current Limitation for Static Compensators
    Camacho, Antonio
    Castilla, Miguel
    Miret, Jaume
    Velasco, Manel
    Guzman, Ramon
    [J]. IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2021, 9 (06) : 6613 - 6623
  • [10] Detection Scheme of Positive Sequence Components Based on Operation Period Delay Filter
    Du, Liwei
    Xiong, Liansong
    Li, Mingxian
    Tang, Zhen
    Xiu, Liancheng
    Ma, Xun
    [J]. CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2023, 9 (01): : 235 - 243