Incorporation of CAD (computer-aided detection) with thin-slice lung CT in routine 18F-FDG PET/CT imaging read-out protocol for detection of lung nodules

被引:2
|
作者
Bhure, Ujwal [1 ]
Cieciera, Matthaus [1 ]
Lehnick, Dirk [2 ,3 ]
Lago, Maria del Sol Perez [1 ]
Grunig, Hannes [1 ]
Lima, Thiago [1 ]
Roos, Justus E. [1 ]
Strobel, Klaus [1 ,4 ]
机构
[1] Cantonal Hosp Lucerne, Dept Nucl Med Radiol, Luzern, Switzerland
[2] Univ Lucerne, Fac Hlth Sci & Med, Frohburgstr 3, CH-6002 Luzern, Switzerland
[3] Univ Lucerne, Clin Trial Unit Cent Switzerland, CH-6002 Luzern, Switzerland
[4] Cantonal Hosp Lucerne, Dept Nucl Med & Radiol, Div Nucl Med, Lucerne 16, CH-6000 Luzern, Switzerland
来源
EUROPEAN JOURNAL OF HYBRID IMAGING | 2023年 / 7卷 / 01期
关键词
Lung nodules; CAD; Computer-aided detection; 18F-FDG PET/CT; Thin-slice CT; Thick-slice CT; Lung metastases; Artificial intelligence; Machine learning; Deep learning; MAXIMUM INTENSITY PROJECTION; PULMONARY NODULES; AUTOMATED DETECTION; TUMOR SEGMENTATION; ASSISTED DETECTION; MALPRACTICE SUITS; MULTIDETECTOR CT; F-18-FDG PET/CT; 2ND READER; PERFORMANCE;
D O I
10.1186/s41824-023-00177-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveTo evaluate the detection rate and performance of 18F-FDG PET alone (PET), the combination of PET and low-dose thick-slice CT (PET/lCT), PET and diagnostic thin-slice CT (PET/dCT), and additional computer-aided detection (PET/dCT/CAD) for lung nodules (LN)/metastases in tumor patients. Along with this, assessment of inter-reader agreement and time requirement for different techniques were evaluated as well.MethodsIn 100 tumor patients (56 male, 44 female; age range: 22-93 years, mean age: 60 years) 18F-FDG PET images, low-dose CT with shallow breathing (5 mm slice thickness), and diagnostic thin-slice CT (1 mm slice thickness) in full inspiration were retrospectively evaluated by three readers with variable experience (junior, mid-level, and senior) for the presence of lung nodules/metastases and additionally analyzed with CAD. Time taken for each analysis and number of the nodules detected were assessed. Sensitivity, specificity, positive and negative predictive value, accuracy, and Receiver operating characteristic (ROC) analysis of each technique was calculated. Histopathology and/or imaging follow-up served as reference standard for the diagnosis of metastases.ResultsThree readers, on an average, detected 40 LN in 17 patients with PET only, 121 LN in 37 patients using ICT, 283 LN in 60 patients with dCT, and 282 LN in 53 patients with CAD. On average, CAD detected 49 extra LN, missed by the three readers without CAD, whereas CAD overall missed 53 LN. There was very good inter-reader agreement regarding the diagnosis of metastases for all four techniques (kappa: 0.84-0.93). The average time required for the evaluation of LN in PET, lCT, dCT, and CAD was 25, 31, 60, and 40 s, respectively; the assistance of CAD lead to average 33% reduction in time requirement for evaluation of lung nodules compared to dCT. The time-saving effect was highest in the less experienced reader. Regarding the diagnosis of metastases, sensitivity and specificity combined of all readers were 47.8%/96.2% for PET, 80.0%/81.9% for PET/lCT, 100%/56.7% for PET/dCT, and 95.6%/64.3% for PET/CAD. No significant difference was observed regarding the ROC AUC (area under the curve) between the imaging methods.ConclusionImplementation of CAD for the detection of lung nodules/metastases in routine 18F-FDG PET/CT read-out is feasible. The combination of diagnostic thin-slice CT and CAD significantly increases the detection rate of lung nodules in tumor patients compared to the standard PET/CT read-out. PET combined with low-dose CT showed the best balance between sensitivity and specificity regarding the diagnosis of metastases per patient. CAD reduces the time required for lung nodule/metastasis detection, especially for less experienced readers.
引用
收藏
页数:14
相关论文
共 37 条
  • [21] The utility of computer-aided detection (CAD) for lung cancer screening using low-dose CT
    Roberts, HC
    Patsios, D
    Kucharczyk, M
    Paul, N
    Roberts, TP
    CARS 2005: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2005, 1281 : 1137 - 1142
  • [22] A new scheme for computer-aided detection of CT lung nodules designed in consideration of ground-glass opacity
    Matsumoto, Sumiaki
    Ohno, Yoshiharu
    Yamagata, Hitoshi
    Asahina, Hiroshi
    Sugimura, Kazuro
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2006, 1 : 352 - 354
  • [23] Incorporation of a computer-aided vessel-suppression system to detect lung nodules in CT images: effect on sensitivity and reading time in routine clinical settings
    Takaishi, Taku
    Ozawa, Yoshiyuki
    Bando, Yuya
    Yamamoto, Akiko
    Okochi, Sachiko
    Suzuki, Hirochika
    Shibamoto, Yuta
    JAPANESE JOURNAL OF RADIOLOGY, 2021, 39 (02) : 159 - 164
  • [24] CAD (computed-aided detection) and CADx (computer aided diagnosis) systems in identifying and characterising lung nodules on chest CT: overview of research, developments and new prospects
    Fraioli, F.
    Serra, G.
    Passariello, R.
    RADIOLOGIA MEDICA, 2010, 115 (03): : 385 - 402
  • [25] Imaging phenotyping using 18F-FDG PET/CT radiomics to predict micropapillary and solid pattern in lung adenocarcinoma
    Linyi Zhou
    Jinju Sun
    He Long
    Weicheng Zhou
    Renxiang Xia
    Yi Luo
    Jingqin Fang
    Yi Wang
    Xiao Chen
    Insights into Imaging, 15
  • [26] Imaging phenotyping using 18F-FDG PET/CT radiomics to predict micropapillary and solid pattern in lung adenocarcinoma
    Zhou, Linyi
    Sun, Jinju
    Long, He
    Zhou, Weicheng
    Xia, Renxiang
    Luo, Yi
    Fang, Jingqin
    Wang, Yi
    Chen, Xiao
    INSIGHTS INTO IMAGING, 2024, 15 (01)
  • [27] Editorial Comment: Computer-Aided Detection of Lung Nodules on Low-Dose Pediatric Chest CT-A Cautionary Tale
    Zucker, Evan J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2025, 224 (01)
  • [28] 18F-FDG PET-CT dual-time imaging in detection and characterization of recurrent lesions in patients with testicular cancer
    Nasr, Ibrahim Mansour
    Talaat, Omnia Mohamed
    Rezk, Mahmoud Aly
    Ali, Ismail Mohamed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2022, 53 (01)
  • [29] Prediction of EGFR Mutation Status Based on 18F-FDG PET/CT Imaging Using Deep Learning-Based Model in Lung Adenocarcinoma
    Yin, Guotao
    Wang, Ziyang
    Song, Yingchao
    Li, Xiaofeng
    Chen, Yiwen
    Zhu, Lei
    Su, Qian
    Dai, Dong
    Xu, Wengui
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [30] Application of dual-stream 3D convolutional neural network based on 18F-FDG PET/CT in distinguishing benign and invasive adenocarcinoma in ground-glass lung nodules
    Shao, Xiaonan
    Niu, Rong
    Shao, Xiaoliang
    Gao, Jianxiong
    Shi, Yunmei
    Jiang, Zhenxing
    Wang, Yuetao
    EJNMMI PHYSICS, 2021, 8 (01)