Incorporation of CAD (computer-aided detection) with thin-slice lung CT in routine 18F-FDG PET/CT imaging read-out protocol for detection of lung nodules

被引:2
|
作者
Bhure, Ujwal [1 ]
Cieciera, Matthaus [1 ]
Lehnick, Dirk [2 ,3 ]
Lago, Maria del Sol Perez [1 ]
Grunig, Hannes [1 ]
Lima, Thiago [1 ]
Roos, Justus E. [1 ]
Strobel, Klaus [1 ,4 ]
机构
[1] Cantonal Hosp Lucerne, Dept Nucl Med Radiol, Luzern, Switzerland
[2] Univ Lucerne, Fac Hlth Sci & Med, Frohburgstr 3, CH-6002 Luzern, Switzerland
[3] Univ Lucerne, Clin Trial Unit Cent Switzerland, CH-6002 Luzern, Switzerland
[4] Cantonal Hosp Lucerne, Dept Nucl Med & Radiol, Div Nucl Med, Lucerne 16, CH-6000 Luzern, Switzerland
来源
EUROPEAN JOURNAL OF HYBRID IMAGING | 2023年 / 7卷 / 01期
关键词
Lung nodules; CAD; Computer-aided detection; 18F-FDG PET/CT; Thin-slice CT; Thick-slice CT; Lung metastases; Artificial intelligence; Machine learning; Deep learning; MAXIMUM INTENSITY PROJECTION; PULMONARY NODULES; AUTOMATED DETECTION; TUMOR SEGMENTATION; ASSISTED DETECTION; MALPRACTICE SUITS; MULTIDETECTOR CT; F-18-FDG PET/CT; 2ND READER; PERFORMANCE;
D O I
10.1186/s41824-023-00177-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveTo evaluate the detection rate and performance of 18F-FDG PET alone (PET), the combination of PET and low-dose thick-slice CT (PET/lCT), PET and diagnostic thin-slice CT (PET/dCT), and additional computer-aided detection (PET/dCT/CAD) for lung nodules (LN)/metastases in tumor patients. Along with this, assessment of inter-reader agreement and time requirement for different techniques were evaluated as well.MethodsIn 100 tumor patients (56 male, 44 female; age range: 22-93 years, mean age: 60 years) 18F-FDG PET images, low-dose CT with shallow breathing (5 mm slice thickness), and diagnostic thin-slice CT (1 mm slice thickness) in full inspiration were retrospectively evaluated by three readers with variable experience (junior, mid-level, and senior) for the presence of lung nodules/metastases and additionally analyzed with CAD. Time taken for each analysis and number of the nodules detected were assessed. Sensitivity, specificity, positive and negative predictive value, accuracy, and Receiver operating characteristic (ROC) analysis of each technique was calculated. Histopathology and/or imaging follow-up served as reference standard for the diagnosis of metastases.ResultsThree readers, on an average, detected 40 LN in 17 patients with PET only, 121 LN in 37 patients using ICT, 283 LN in 60 patients with dCT, and 282 LN in 53 patients with CAD. On average, CAD detected 49 extra LN, missed by the three readers without CAD, whereas CAD overall missed 53 LN. There was very good inter-reader agreement regarding the diagnosis of metastases for all four techniques (kappa: 0.84-0.93). The average time required for the evaluation of LN in PET, lCT, dCT, and CAD was 25, 31, 60, and 40 s, respectively; the assistance of CAD lead to average 33% reduction in time requirement for evaluation of lung nodules compared to dCT. The time-saving effect was highest in the less experienced reader. Regarding the diagnosis of metastases, sensitivity and specificity combined of all readers were 47.8%/96.2% for PET, 80.0%/81.9% for PET/lCT, 100%/56.7% for PET/dCT, and 95.6%/64.3% for PET/CAD. No significant difference was observed regarding the ROC AUC (area under the curve) between the imaging methods.ConclusionImplementation of CAD for the detection of lung nodules/metastases in routine 18F-FDG PET/CT read-out is feasible. The combination of diagnostic thin-slice CT and CAD significantly increases the detection rate of lung nodules in tumor patients compared to the standard PET/CT read-out. PET combined with low-dose CT showed the best balance between sensitivity and specificity regarding the diagnosis of metastases per patient. CAD reduces the time required for lung nodule/metastasis detection, especially for less experienced readers.
引用
收藏
页数:14
相关论文
共 37 条
  • [1] Incorporation of CAD (computer-aided detection) with thin-slice lung CT in routine 18F-FDG PET/CT imaging read-out protocol for detection of lung nodules
    Ujwal Bhure
    Matthäus Cieciera
    Dirk Lehnick
    Maria del Sol Pérez Lago
    Hannes Grünig
    Thiago Lima
    Justus E. Roos
    Klaus Strobel
    European Journal of Hybrid Imaging, 7
  • [2] A comparison of axial versus coronal image viewing in computer-aided detection of lung nodules on CT
    Iwasawa, Tae
    Matsumoto, Sumiaki
    Aoki, Takatoshi
    Okada, Fumito
    Nishimura, Yoshihiro
    Yamagata, Hitoshi
    Ohno, Yoshiharu
    JAPANESE JOURNAL OF RADIOLOGY, 2015, 33 (02) : 76 - 83
  • [3] Performance analysis of a computer-aided detection system for lung nodules in CT at different slice thicknesses
    Narayanan, Barath Narayanan
    Hardie, Russell Craig
    Kebede, Temesguen Messay
    JOURNAL OF MEDICAL IMAGING, 2018, 5 (01)
  • [4] Computer-aided detection (CAD) of lung nodules in CT scans: radiologist performance and reading time with incremental CAD assistance
    Roos, Justus E.
    Paik, David
    Olsen, David
    Liu, Emily G.
    Chow, Lawrence C.
    Leung, Ann N.
    Mindelzun, Robert
    Choudhury, Kingshuk R.
    Naidich, David P.
    Napel, Sandy
    Rubin, Geoffrey D.
    EUROPEAN RADIOLOGY, 2010, 20 (03) : 549 - 557
  • [5] Computer-aided detection (CAD) of lung nodules in CT scans: radiologist performance and reading time with incremental CAD assistance
    Justus E. Roos
    David Paik
    David Olsen
    Emily G. Liu
    Lawrence C. Chow
    Ann N. Leung
    Robert Mindelzun
    Kingshuk R. Choudhury
    David P. Naidich
    Sandy Napel
    Geoffrey D. Rubin
    European Radiology, 2010, 20 : 549 - 557
  • [6] Deep Learning-Based Slice Thickness Reduction for Computer-Aided Detection of Lung Nodules in Thick-Slice CT
    Jeong, Jonghun
    Park, Doohyun
    Kang, Jung-Hyun
    Kim, Myungsub
    Kim, Hwa-Young
    Choi, Woosuk
    Ham, Soo-Youn
    DIAGNOSTICS, 2024, 14 (22)
  • [7] Lung nodule detection on chest CT: Evaluation of a computer-aided detection (CAD) system
    Lee, IJ
    Gamsu, G
    Czum, J
    Wu, N
    Johnson, R
    Chakrapani, S
    KOREAN JOURNAL OF RADIOLOGY, 2005, 6 (02) : 89 - 93
  • [8] Computer-Aided Detection (CADe) System for Detection of Malignant Lung Nodules in CT Slices - a Key for Early Lung Cancer Detection
    Bajwa, Usama Ijaz
    Shah, Abdullah Ali
    Anwar, Muhammad Waqas
    Gilanie, Ghulam
    Bajwa, Asma Ejaz
    CURRENT MEDICAL IMAGING REVIEWS, 2018, 14 (03) : 422 - 429
  • [9] Shape-Based Computer-Aided Detection of Lung Nodules in Thoracic CT Images
    Ye, Xujiong
    Lin, Xinyu
    Dehmeshki, Jamshid
    Slabaugh, Greg
    Beddoe, Gareth
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (07) : 1810 - 1820
  • [10] Computer-Aided Detection of Lung Nodules on CT With a Computerized Pulmonary Vessel Suppressed Function
    Lo, ShihChung B.
    Freedman, Matthew T.
    Gillis, Laura B.
    White, Charles S.
    Mun, Seong K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (03) : 480 - 488