Research on Technology System Adaptability of Nearly Zero-Energy Office Buildings in the Hot Summer and Cold Winter Zone of China

被引:0
|
作者
Jia, Xueying [1 ]
Zhang, Hui [1 ,2 ]
Yao, Xin [3 ]
Yang, Lei [3 ]
Ke, Zikang [1 ]
Yan, Junle [1 ]
Huang, Xiaoxi [1 ]
Jin, Shiyu [1 ]
机构
[1] Hubei Univ Technol, Sch Civil Engn Architecture & Environm, Wuhan 430068, Peoples R China
[2] Natl Univ Singapore, Coll Design & Engn, Singapore 117566, Singapore
[3] Cent South Architectural Design Inst Co Ltd, Wuhan 430061, Peoples R China
关键词
nearly zero-energy office buildings; complex and diverse climates; technology system; passive design; orthogonal experiment; DIFFERENT CLIMATE ZONES; PARAMETRIC ANALYSIS; EFFICIENCY; DESIGN; CONSUMPTION; NZEB; PERFORMANCE; SIMULATION; STANDARDS; SAVINGS;
D O I
10.3390/su151713061
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the current context of huge global energy consumption and harsh climatic conditions, the energy efficiency and sustainability of buildings have received much attention. The nearly zero-energy building (nZEB) is a feasible solution for solving the energy crisis in the building sector in recent years, and it is important to study the adaptability of its technology system. However, existing studies have not addressed well the issue of the impact of complex and diverse climates on the technology systems of nZEBs. Secondly, in contrast to residential buildings, nearly zero-energy technology systems for office buildings need to be further developed. This study takes the hot summer and cold winter (HSCW) zone of China as an example and uses numerical simulations and orthogonal experiments to investigate the adaptability of nearly zero-energy office building technology systems under complex and diverse climate conditions. The results show the following: (1) Passive technologies are greatly affected by the complexity and diversity of climates. Optimal envelope thermal parameters tailored to specific zones are identified. Specifically, the optimal level of KWALL in the CT and HSCWC zones is 0.2 W/(m2 & BULL;K), and the optimal level of KWALL in the HSWWT zone is 0.3 W/(m2 & BULL;K); the optimal level of KROOF in the CT zone is 0.15 W/(m2 & BULL;K), and the optimal level of KROOF in the HSCWC and HSWWT zones is 0.25 W/(m2 & BULL;K); (2) Active technologies do not mainly receive the influence of the complexity and diversity of climates, and ED, HR, and TS measures should be adopted for office buildings; (3) The rational utilization of renewable energy is influenced by local resource conditions. This study evaluates the adaptability of GSHP, ASHP, and BIPV technologies. To better meet the requirements of nearly zero-energy office buildings, it is recommended to adopt GSHP for the CT zone and ASHP for the HCWWT zone. This study will be helpful for the development of nearly zero-energy office building technology systems in other complex and diverse climatic zones.
引用
收藏
页数:21
相关论文
共 50 条
  • [41] Experimental research on a novel sun shading & solar energy collecting coupling device for inpatient building in hot summer and cold winter climate zone in China
    Luo, Songqin
    Li, Hongqiang
    Mao, Yingjie
    Yang, Changzhi
    APPLIED THERMAL ENGINEERING, 2018, 142 : 89 - 99
  • [42] Low carbon heating and cooling of residential buildings in cities in the hot summer and cold winter zone - A bottom-up engineering stock modeling approach
    Li, Xinyi
    Yao, Runming
    Yu, Wei
    Meng, Xiangzhong
    Liu, Meng
    Short, Alan
    Li, Baizhan
    JOURNAL OF CLEANER PRODUCTION, 2019, 220 : 271 - 288
  • [43] Using Real Building Energy Use Data to Explain the Energy Performance Gap of Energy-Efficient Residential Buildings: A Case Study from the Hot Summer and Cold Winter Zone in China
    Wang, Xia
    Yuan, Jiachen
    You, Kairui
    Ma, Xianrui
    Li, Zhaoji
    SUSTAINABILITY, 2023, 15 (02)
  • [44] Energy savings potential of a desiccant assisted hybrid air source heat pump system for residential building in hot summer and cold winter zone in China
    Ge, Fenghua
    Guo, Xinglong
    Hu, Zicheng
    Chu, Yi
    ENERGY AND BUILDINGS, 2011, 43 (12) : 3521 - 3527
  • [45] Influence of occupant behaviour on oversizing issue of heat pumps for residential district in Hot Summer and Cold Winter zone of China
    Qian, Mingyang
    Yan, Da
    Zhang, Lun
    Zhou, Xin
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 2434 - 2441
  • [46] Energy-efficiency strategies of residential envelope in China's Hot Summer-Cold Winter Zone based on intermittent thermal regulation behaviour
    Ge, Jian
    Li, Senmiao
    Chen, Shuqin
    Wang, Xinzhen
    Jiang, Ziling
    Shen, Cheng
    JOURNAL OF BUILDING ENGINEERING, 2021, 44
  • [47] Quantitative Study of Using Piloti for Passive Climate Adaptability in a Hot-Summer and Cold-Winter City in China
    Zhou, Zeng
    Deng, Qinli
    Yang, Guang
    Lin, Yaolin
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2018, 15 (10)
  • [48] The hot summer-cold winter region in China: Challenges in the low carbon adaptation of residential slab buildings to enhance comfort
    Laetitia, Mottet
    Song Jiyun
    Alan, Short C.
    Chen Shuqin
    Wu Jindong
    Wei, Yu
    Jie, Xiong
    Zhang Qiulei
    Jian, Ge
    Meng, Liu
    Yao Runming
    Li Baizhan
    ENERGY AND BUILDINGS, 2020, 223
  • [49] A comprehensive comparison study on household solar-assisted heating system performance in the hot summer and cold winter zone in China
    Li, Tao
    Liu, Qingxia
    Wang, Xing
    Gao, Jiajia
    Li, Guannan
    Mao, Qianjun
    JOURNAL OF CLEANER PRODUCTION, 2024, 434
  • [50] Study on Building Energy Effciency of Reflective Coatings in Hot Summer and Warmer Winter Zone of China
    Liang, Qing
    Han, Xinxin
    Liu, Jing
    Xu, Gang
    RENEWABLE AND SUSTAINABLE ENERGY, PTS 1-7, 2012, 347-353 : 3139 - +