Research on Technology System Adaptability of Nearly Zero-Energy Office Buildings in the Hot Summer and Cold Winter Zone of China

被引:0
|
作者
Jia, Xueying [1 ]
Zhang, Hui [1 ,2 ]
Yao, Xin [3 ]
Yang, Lei [3 ]
Ke, Zikang [1 ]
Yan, Junle [1 ]
Huang, Xiaoxi [1 ]
Jin, Shiyu [1 ]
机构
[1] Hubei Univ Technol, Sch Civil Engn Architecture & Environm, Wuhan 430068, Peoples R China
[2] Natl Univ Singapore, Coll Design & Engn, Singapore 117566, Singapore
[3] Cent South Architectural Design Inst Co Ltd, Wuhan 430061, Peoples R China
关键词
nearly zero-energy office buildings; complex and diverse climates; technology system; passive design; orthogonal experiment; DIFFERENT CLIMATE ZONES; PARAMETRIC ANALYSIS; EFFICIENCY; DESIGN; CONSUMPTION; NZEB; PERFORMANCE; SIMULATION; STANDARDS; SAVINGS;
D O I
10.3390/su151713061
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the current context of huge global energy consumption and harsh climatic conditions, the energy efficiency and sustainability of buildings have received much attention. The nearly zero-energy building (nZEB) is a feasible solution for solving the energy crisis in the building sector in recent years, and it is important to study the adaptability of its technology system. However, existing studies have not addressed well the issue of the impact of complex and diverse climates on the technology systems of nZEBs. Secondly, in contrast to residential buildings, nearly zero-energy technology systems for office buildings need to be further developed. This study takes the hot summer and cold winter (HSCW) zone of China as an example and uses numerical simulations and orthogonal experiments to investigate the adaptability of nearly zero-energy office building technology systems under complex and diverse climate conditions. The results show the following: (1) Passive technologies are greatly affected by the complexity and diversity of climates. Optimal envelope thermal parameters tailored to specific zones are identified. Specifically, the optimal level of KWALL in the CT and HSCWC zones is 0.2 W/(m2 & BULL;K), and the optimal level of KWALL in the HSWWT zone is 0.3 W/(m2 & BULL;K); the optimal level of KROOF in the CT zone is 0.15 W/(m2 & BULL;K), and the optimal level of KROOF in the HSCWC and HSWWT zones is 0.25 W/(m2 & BULL;K); (2) Active technologies do not mainly receive the influence of the complexity and diversity of climates, and ED, HR, and TS measures should be adopted for office buildings; (3) The rational utilization of renewable energy is influenced by local resource conditions. This study evaluates the adaptability of GSHP, ASHP, and BIPV technologies. To better meet the requirements of nearly zero-energy office buildings, it is recommended to adopt GSHP for the CT zone and ASHP for the HCWWT zone. This study will be helpful for the development of nearly zero-energy office building technology systems in other complex and diverse climatic zones.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] Energy Efficiency for Airtightness and Exterior Wall Insulation of Passive Houses in Hot Summer and Cold Winter Zone of China
    Fu, Xin
    Qian, Xiaoqian
    Wang, Lina
    SUSTAINABILITY, 2017, 9 (07)
  • [22] Multiobjective optimization of daylighting, energy, and thermal performance for form variables in atrium buildings in China's hot summer and cold winter climate
    Xiao, Wei
    Zhong, Wenzhou
    Wu, Haoran
    Zhang, Tong
    ENERGY AND BUILDINGS, 2023, 297
  • [23] Numerical investigation for thermal performance of exterior walls of residential buildings with moisture transfer in hot summer and cold winter zone of China
    Liu, Xiangwei
    Chen, Youming
    Ge, Hua
    Fazio, Paul
    Chen, Guojie
    ENERGY AND BUILDINGS, 2015, 93 : 259 - 268
  • [24] Numerical Simulation Modeling of a GSHP and WSHP System for an Office Building in the Hot Summer and Cold Winter Region of China: A Case Study in Suzhou
    Ma, Wenting
    Kim, Moon Keun
    Hao, Jianli
    SUSTAINABILITY, 2019, 11 (12)
  • [25] A review on applying ventilated double-skin facade to buildings in hot-summer and cold-winter zone in China
    Zhou, Juan
    Chen, Youming
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2010, 14 (04) : 1321 - 1328
  • [26] Sensitivity Analysis and Optimization of Energy-Saving Measures for Office Building in Hot Summer and Cold Winter Regions
    Xuanyuan, Peisong
    Zhang, Yijie
    Yao, Jian
    Zheng, Rongyue
    ENERGIES, 2024, 17 (07)
  • [27] Analysis of district cooling system with chilled water thermal storage in hot summer and cold winter area of China
    Zhang, Lun
    Jing, Jun
    Duan, Mengfan
    Qian, Mingyang
    Yan, Da
    Zhang, Xiaosong
    BUILDING SIMULATION, 2020, 13 (02) : 349 - 361
  • [28] A review of renewable energy applications in buildings in the hot-summer and warm-winter region of China
    Li, Dayao
    He, Jiang
    Li, Lin
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 57 : 327 - 336
  • [29] Optimization Analysis of the Residential Window-to-Wall Ratio Based on Numerical Calculation of Energy Consumption in the Hot-Summer and Cold-Winter Zone of China
    Liu, Haiqiang
    Zhang, Zhihao
    Ma, Xidong
    Lu, Weite
    Li, Dongze
    Kojima, Shoichi
    SUSTAINABILITY, 2021, 13 (11)
  • [30] Retrofit Analysis of City-Scale Residential Buildings in the Hot Summer and Cold Winter Climate Zone
    Ji, Yanfei
    Li, Guangchen
    Su, Fanghan
    Chen, Yixing
    Zhang, Rongpeng
    Asdrubali, Francesco
    Zhang, Weirong
    Li, Ning
    Dai, Jian
    Li, Ziwei
    ENERGIES, 2023, 16 (17)