Timing Estimation and Limits in TOF-PET Detectors Producing Prompt Photons

被引:0
|
作者
Loignon-Houle, Francis [1 ]
Toussaint, Maxime [1 ]
Bertrand, Emilie [2 ,3 ]
Lemyre, Felix Camirand [2 ,3 ]
Lecomte, Roger [1 ]
机构
[1] Univ Politecn Valencia, Inst Instrumentac Imagen Mol, Ctr Mixto CSIC, Valencia 46022, Spain
[2] Ctr Rech CHUS CRCHUS, Sherbrooke, PQ J1H 5N4, Canada
[3] Univ Sherbrooke, Dept Math, Sherbrooke, PQ J1H5N4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Prompt photons; scintillation detectors; time resolution; time-of-flight (TOF) positron emission tomography (PET); LOWER BOUNDS; X-RAY; TIME; RESOLUTION; SCINTILLATORS; TRADEOFFS; RISE;
D O I
10.1109/TRPMS.2023.3279455
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The production of prompt photons providing high photon time densities is a promising avenue to reach ultrahigh coincidence time resolution (CTR) in time-of-flight positron emission tomography. Detectors producing prompt photons are receiving high interest experimentally, ignited by past exploratory theoretical studies that have anchored some guiding principles. Here, we aim to consolidate and extend the foundations for the analytical modeling of prompt generating detectors. We extend the current models to a larger range of prompt emission kinetics where more stringent requirements on the prompt photon yield rapidly emerge as a limiting factor. Lower bound and estimator evaluations are investigated with different underlying models, notably by merging or keeping separate the prompt and scintillation photon populations. We further show the potential benefits of knowing the proportion of prompt photons within a detection set to improve the CTR by mitigating the detrimental effect of population (prompt versus scintillation) mixing. Taking into account the fluctuations on the average number of detected prompt photons in the model reveals a limited influence when prompt photons are accompanied by fast scintillation (e.g., LSO:Ce:Ca) but a more significant effect when accompanied by slower scintillation (e.g., bismuth germanate). Establishing performance characteristics and limitations of prompt generating detectors is paramount to gauging and targeting the best possible timing capabilities they can offer.
引用
收藏
页码:692 / 703
页数:12
相关论文
共 50 条
  • [1] Optimizing the timing resolution of SiPM sensors for use in TOF-PET detectors
    Vinke, R.
    Lohner, H.
    Schaart, D. R.
    van Dam, H. T.
    Seifert, S.
    Beekman, F. J.
    Dendooven, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 610 (01): : 188 - 191
  • [2] Fast Timing MPGD for ToF-PET
    Errico, F.
    Colaleo, A.
    Maggi, M.
    Pellecchia, A.
    Radogna, R.
    Verwilligen, P. O. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1042
  • [3] Improving timing performance of double-ended readout in TOF-PET detectors
    Guo, L.
    Tian, J.
    Chen, P.
    Derenzo, S. E.
    Choong, W. -S
    JOURNAL OF INSTRUMENTATION, 2020, 15 (01)
  • [4] Energy Estimation Technique Utilizing Timing Information for TOF-PET Application
    Mandai, Shingo
    Venialgo, Esteban
    Charbon, Edoardo
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [5] Estimation of crystal timings in TOF-PET
    Rezaei, Ahmadreza
    Schramm, Georg
    Van Laere, Koen
    Nuyts, Johan
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [6] High Voltage Photodetector Calibration for Improved Timing Resolution with Scintillation Detectors for TOF-PET Imaging
    Davidson, Z. S.
    Wiener, R. I.
    Newcomer, F. M.
    VanBerg, R.
    Karp, J. S.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2338 - 2341
  • [7] Timing Resolution Improvement of MPPC for TOF-PET Imaging
    Nagano, T.
    Sato, K.
    Ishida, A.
    Baba, T.
    Tsuchiya, R.
    Yamamoto, K.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1577 - 1580
  • [8] TOF-PET Detectors Based on ASIC Technology and Analog SiPMs
    Lamprou, Efthymios
    Gonzalez-Montoro, Andrea
    Canizares, Gabriel
    Ilisie, Victor
    Sanchez, Filomeno
    Freire, Marta
    Hernandez, Liczandro
    Vidal, Luis F.
    Barrio, John
    Gonzalez, Antonio J.
    Benlloch, Jose M.
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [9] Timing limits of ultrafast cross-luminescence emission in CsZnCl-based crystals for TOF-CT and TOF-PET
    Herweg, Katrin
    Rutstrom, Daniel
    Nadig, Vanessa
    Stand, Luis
    Melcher, Charles L.
    Zhuravleva, Mariya
    Schulz, Volkmar
    Gundacker, Stefan
    EJNMMI PHYSICS, 2024, 11 (01):
  • [10] Fast timing monolithic silicon pixel sensor for TOF-PET
    Hayakawa, D.
    Iacobucci, G.
    Paolozzi, L.
    Valerio, P.
    Ripiccini, E.
    Benoit, M.
    Ratib, O.
    Cardarelli, R.
    Bruno, S.
    Caltabiano, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 924 : 339 - 342