A novel noniterative single-ended fault location method with distributed parameter model for AC transmission lines

被引:1
|
作者
Duan, Mengzhao [1 ]
Liu, Yu [1 ,2 ]
Lu, Dian [1 ]
Pan, Ruiyu [1 ]
机构
[1] ShanghaiTech Univ, Sch Informat Sci & Technol, Shanghai 201210, Peoples R China
[2] Minist Educ, Key Lab Control Power Transmiss & Convers SJTU, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金;
关键词
Fault location; Noniterative method; Single-ended measurements; Distributed parameter model; DYNAMIC STATE ESTIMATION; VOLTAGE;
D O I
10.1016/j.ijepes.2023.109358
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Fast and accurate fault location methods can save costs and ensure power supply reliability. This paper proposes a novel noniterative single-ended phasor domain fault location method with distributed parameter model for AC transmission lines. Due to the limitation of information, the legacy impedance-based single-ended fault location methods usually are based on assumptions on the line or system to obtain more information. The method proposed in this paper takes advantage of the additional information brought by the operation mode of circuit breakers. The proposed method only needs the local measurements and does not need the measurements and the equivalent source parameters of the remote system. The proposed method only uses single-ended data and is not affected by communication and synchronization. The proposed method is noniterative and there is no risk of nonconvergence. In addition, the method proposed in this paper does not rely on the assumptions of legacy methods and considers the distributed parameters, avoiding the disadvantages of the legacy methods. The effectiveness of the proposed method is verified through a lot of case studies in PSCAD/EMTDC, with different fault types, fault locations and resistances. & COPY; 2017 Elsevier Inc. All rights reserved.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Reflected Traveling Wave Based Single-Ended Fault Location in Distribution Networks
    Shi, Yangang
    Zheng, Tao
    Yang, Chang
    ENERGIES, 2020, 13 (15)
  • [42] A novel single-end fault location method for double-circuit transmission lines
    Arpanahi, Moossa Khodadadi
    Fini, Masoud Hajiakbari
    Nateghi, Abolfazl
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 158
  • [43] Single Ended Fault Location Method for Lines Connected with Inverter Based Renewable Resources
    Naidu, O. D.
    Aarthi, V
    Likhitha, Kukkala
    2023 IEEE PES 15TH ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE, APPEEC, 2023,
  • [44] Modified Single-Ended Fault Location Method for Single-phase-to-Ground Faults in T-Connected Line
    He, Xin
    Zhao, Yiming
    Shi, Shenxing
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [45] Parameter Identification Algorithm for Fault Location Based on Distributed Transmission Line model
    Kang, Xiaoning
    Jiale, Suonan
    Bo, Zhiqian
    Tang, Jian
    Jun, Qi
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 4098 - +
  • [46] A Traveling Wave Based Single-Ended Fault Location Algorithm using DWT for Overhead Lines Combined with Underground Cables
    Livani, Hanif
    Evrenosoglu, Cansin Yaman
    IEEE PES GENERAL MEETING, 2010,
  • [47] A Simple Single-Ended Post-Fault Location Technique for DC Lines Based on Controlled Re-Energizations
    Mahtani, Kumar
    Guerrero, Jose M.
    Decroix, Julien
    Platero, Carlos A.
    ELECTRONICS, 2025, 14 (02):
  • [48] A novel line parameter adaptive phasor domain fault location method for double-circuit transmission lines
    Liang, Yuansheng
    Zhang, Zihong
    Li, Haifeng
    Ding, Jiayan
    Wang, Gang
    Chen, Juan
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 214
  • [49] A Fault Location Method for HVDC Transmission Lines
    Xing, Luhua
    Chen, Qing
    Xue, Binglei
    MECHATRONICS ENGINEERING, COMPUTING AND INFORMATION TECHNOLOGY, 2014, 556-562 : 2723 - 2727
  • [50] A fault location method for parallel transmission lines
    Sheng, LB
    Elangovan, S
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 1999, 21 (04) : 253 - 259