Variability in Grading Diabetic Retinopathy Using Retinal Photography and Its Comparison with an Automated Deep Learning Diabetic Retinopathy Screening Software

被引:3
|
作者
Teoh, Chin Sheng [1 ]
Wong, Kah Hie [1 ]
Xiao, Di [2 ]
Wong, Hung Chew [3 ]
Zhao, Paul [1 ]
Chan, Hwei Wuen [1 ]
Yuen, Yew Sen [1 ]
Naing, Thet [1 ]
Yogesan, Kanagasingam [4 ]
Koh, Victor Teck Chang [1 ,5 ]
机构
[1] Natl Univ Hlth Syst, Dept Ophthalmol, Singapore 119228, Singapore
[2] CSIRO, Urrbrae 5064, Australia
[3] Natl Univ Singapore, Yong Loo Lin Sch Med, Med Biostat Unit, Singapore 119077, Singapore
[4] Univ Notre Dame, Sch Med, Fremantle 6160, Australia
[5] Natl Univ Singapore, Ctr Innovat & Precis Eye Hlth, Yong Loo Lin Sch Med, Singapore 119077, Singapore
关键词
automated screening software; deep learning; diabetes retinopathy; grading; variability; TELEMEDICINE; AGREEMENT; PROGRAM;
D O I
10.3390/healthcare11121697
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Diabetic retinopathy (DR) screening using colour retinal photographs is cost-effective and time-efficient. In real-world clinical settings, DR severity is frequently graded by individuals of different expertise levels. We aim to determine the agreement in DR severity grading between human graders of varying expertise and an automated deep learning DR screening software (ADLS). Methods: Using the International Clinical DR Disease Severity Scale, two hundred macula-centred fundus photographs were graded by retinal specialists, ophthalmology residents, family medicine physicians, medical students, and the ADLS. Based on referral urgency, referral grading was divided into no referral, non-urgent referral, and urgent referral to an ophthalmologist. Inter-observer and intra-group variations were analysed using Gwet's agreement coefficient, and the performance of ADLS was evaluated using sensitivity and specificity. Results: The agreement coefficient for inter-observer and intra-group variability ranged from fair to very good, and moderate to good, respectively. The ADLS showed a high area under curve of 0.879, 0.714, and 0.836 for non-referable DR, non-urgent referable DR, and urgent referable DR, respectively, with varying sensitivity and specificity values. Conclusion: Inter-observer and intra-group agreements among human graders vary widely, but ADLS is a reliable and reasonably sensitive tool for mass screening to detect referable DR and urgent referable DR.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] DIABETIC RETINOPATHY GRADING USING DEEP NEURAL NETWORK
    Ramachandran, Nishan
    Chiong, Hong Sheng
    Sime, Mary Jane
    Wilson, Graham
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 45 : 34 - 35
  • [32] Automated Grading of Diabetic Retinopathy with Ultra-Widefield Fluorescein Angiography and Deep Learning
    Wang, Xiaoling
    Ji, Zexuan
    Ma, Xiao
    Zhang, Ziyue
    Yi, Zuohuizi
    Zheng, Hongmei
    Fan, Wen
    Chen, Changzheng
    JOURNAL OF DIABETES RESEARCH, 2021, 2021
  • [33] Diabetic retinopathy detection and grading of retinal fundus images using coyote optimization algorithm with deep learning
    Parthiban, K.
    Kamarasan, M.
    MULTIMEDIA TOOLS AND APPLICATIONS, 2023, 82 (12) : 18947 - 18966
  • [34] Diabetic retinopathy detection and grading of retinal fundus images using coyote optimization algorithm with deep learning
    K. Parthiban
    M. Kamarasan
    Multimedia Tools and Applications, 2023, 82 : 18947 - 18966
  • [35] A Universal Retinal Image Template for Automated Screening of Diabetic Retinopathy
    V. V. Starovoitov
    Yu. I. Golub
    M. M. Lukashevich
    Pattern Recognition and Image Analysis, 2022, 32 : 322 - 331
  • [36] A Universal Retinal Image Template for Automated Screening of Diabetic Retinopathy
    Starovoitov, V. V.
    Golub, Yu. I.
    Lukashevich, M. M.
    PATTERN RECOGNITION AND IMAGE ANALYSIS, 2022, 32 (02) : 322 - 331
  • [37] SCREENING FOR DIABETIC-RETINOPATHY - ANNUAL RETINAL PHOTOGRAPHY IS NOT AN OPTION IN INDIA
    SINGH, KJ
    MISRA, RN
    BAJAJ, S
    MALIK, A
    BRITISH MEDICAL JOURNAL, 1995, 311 (7014): : 1230 - 1230
  • [38] Screening for diabetic retinopathy: The utility of nonmydriatic retinal photography in Egyptian adults
    Penman, AD
    Saaddine, JB
    Hegazy, M
    Sous, ES
    Ali, MA
    Brechner, RJ
    Herman, WH
    Engelgau, MM
    Klein, R
    DIABETIC MEDICINE, 1998, 15 (09) : 783 - 787
  • [39] Mobile retinal photography - A means of screening for diabetic retinopathy in Aboriginal communities
    Karagiannis, A
    Newland, H
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1996, 24 (04): : 333 - 337
  • [40] Deep Learning for Diabetic Retinopathy Early Detection and Severity Grading
    Bouslimi, Dhia Elhak
    Bouslimi, Yahia
    Echi, Afef Kacem
    Ben Ayed, Leila
    2024 IEEE 7TH INTERNATIONAL CONFERENCE ON ADVANCED TECHNOLOGIES, SIGNAL AND IMAGE PROCESSING, ATSIP 2024, 2024, : 165 - 170