Nano X Image Guidance in radiation therapy: feasibility study protocol for cone beam computed tomography imaging with gravity-induced motion

被引:0
|
作者
Debrot, Emily [1 ]
Liu, Paul [1 ]
Gardner, Mark [1 ]
Heng, Soo Min [2 ]
Chan, Chin Hwa [2 ]
Corde, Stephanie [2 ]
Downes, Simon [2 ]
Jackson, Michael [2 ]
Keall, Paul [1 ]
机构
[1] Univ Sydney, ACRF Image Inst 10, Fac Med & Hlth, Camperdown, NSW, Australia
[2] Prince Wales Hosp, Nelune Comprehens Canc Ctr, Randwick, NSW, Australia
基金
澳大利亚国家健康与医学研究理事会; 英国医学研究理事会;
关键词
Image-guided radiotherapy; Image reconstruction; Cone beam CT; RADIOTHERAPY;
D O I
10.1186/s40814-023-01340-z
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
BackgroundThis paper describes the protocol for the Nano X Image Guidance (Nano X IG) trial, a single-institution, clinical imaging study. The Nano X is a prototype fixed-beam radiotherapy system developed to investigate the feasibility of a low-cost, compact radiotherapy system to increase global access to radiation therapy. This study aims to assess the feasibility of volumetric image guidance with cone beam computed tomography (CBCT) acquired during horizontal patient rotation on the Nano X radiotherapy system.MethodsIn the Nano X IG study, we will determine whether radiotherapy image guidance can be performed with the Nano X radiotherapy system where the patient is horizontally rotated while scan projections are acquired. We will acquire both conventional CBCT scans and Nano X CBCT scans for 30 patients aged 18 and above and receiving radiotherapy for head/neck or upper abdomen cancers. For each patient, a panel of experts will assess the image quality of Nano X CBCT scans against conventional CBCT scans. Each patient will receive two Nano X CBCT scans to determine the image quality reproducibility, the extent and reproducibility of patient motion and assess patient tolerance.DiscussionFixed-beam radiotherapy systems have the potential to help ease the current shortfall and increase global access to radiotherapy treatment. Advances in image guidance could facilitate fixed-beam radiotherapy using horizontal patient rotation. The efficacy of this radiotherapy approach is dependent on our ability to image and adapt to motion due to rotation and for patients to tolerate rotation during treatment.
引用
收藏
页数:7
相关论文
共 48 条
  • [31] Feasibility study of a synchronized-moving-grid (SMOG) system to improve image quality in cone-beam computed tomography (CBCT)
    Ren, Lei
    Yin, Fang-Fang
    Chetty, Indrin J.
    Jaffray, David A.
    Jin, Jian-Yue
    MEDICAL PHYSICS, 2012, 39 (08) : 5099 - 5110
  • [32] DAILY IMAGE GUIDANCE WITH CONE-BEAM COMPUTED TOMOGRAPHY FOR HEAD-AND-NECK CANCER INTENSITY-MODULATED RADIOTHERAPY: A PROSPECTIVE STUDY
    Den, Robert B.
    Doemer, Anthony
    Kubicek, Greg
    Bednarz, Greg
    Galvin, James M.
    Keane, William M.
    Xiao, Ying
    Machtay, Mitchell
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (05): : 1353 - 1359
  • [33] Quantitative evaluation of cone-beam computed tomography in target volume definition for offline image-guided radiation therapy of prostate cancer
    Wang, Weihu
    Wu, Qiuwen
    Yan, Di
    RADIOTHERAPY AND ONCOLOGY, 2010, 94 (01) : 71 - 75
  • [34] Assessment of organ doses from head and neck cone-beam computed tomography (CBCT) in adaptive radiation therapy: A phantom study
    Paduka, Sumana
    Thongsawad, Sangutid
    Janthawanno, Patthra
    Krikaew, Kanyanat
    Khaeongrod, Rawisara
    Ketphan, Kornkanok
    Saiyo, Nipon
    RADIATION PHYSICS AND CHEMISTRY, 2024, 215
  • [35] Imaging dose of cone-beam computed tomography in nanoparticle-enhanced image-guided radiotherapy: A Monte Carlo phantom study
    Mututantri-Bastiyange, Dewmini
    Chow, James C. L.
    AIMS BIOENGINEERING, 2020, 7 (01): : 1 - 11
  • [36] MEASURING INTERFRACTIONAL AND INTRAFRACTIONAL MOTION WITH CONE BEAM COMPUTED TOMOGRAPHY AND AN OPTICAL LOCALIZATION SYSTEM FOR LOWER EXTREMITY SOFT TISSUE SARCOMA PATIENTS TREATED WITH PREOPERATIVE INTENSITY-MODULATED RADIATION THERAPY
    Dickie, Colleen I.
    Parent, Amy L.
    Chung, Peter W. M.
    Catton, Charles N.
    Craig, Tim
    Griffin, Anthony M.
    Panzarella, Tony
    Ferguson, Peter C.
    Wunder, Jay S.
    Bell, Robert S.
    Sharpe, Michael B.
    O'Sullivan, Brian
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (05): : 1437 - 1444
  • [37] Image quality evaluation of in-treatment four-dimensional cone-beam computed tomography in volumetric-modulated arc therapy for stereotactic body radiation therapy
    Shimohigashi, Yoshinobu
    Doi, Yasuhiro
    Kouno, Yumiko
    Yotsuji, Yohei
    Maruyama, Masato
    Kai, Yudai
    Toya, Ryo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 68 : 10 - 16
  • [38] Radiation exposure to the patients in thoracic and lumbar spine fusion using a new intraoperative cone-beam computed tomography imaging technique: a preliminary study
    Ludovic Kaminski
    V. Cordemans
    O. Cartiaux
    M. Van Cauter
    European Spine Journal, 2017, 26 : 2811 - 2817
  • [39] Radiation exposure to the patients in thoracic and lumbar spine fusion using a new intraoperative cone-beam computed tomography imaging technique: a preliminary study
    Kaminski, Ludovic
    Cordemans, V.
    Cartiaux, O.
    Van Cauter, M.
    EUROPEAN SPINE JOURNAL, 2017, 26 (11) : 2811 - 2817
  • [40] Interfractional and intrafractional errors assessed by daily cone-beam computed tomography in nasopharyngeal carcinoma treated with intensity-modulated radiation therapy: a prospective study
    Lu, Heming
    Lin, Hui
    Feng, Guosheng
    Chen, Jiaxin
    Shu, Liuyang
    Pang, Qiang
    Cheng, Jinjian
    Peng, Luxing
    Wu, Danling
    Liao, Chaolong
    Mo, Ying
    JOURNAL OF RADIATION RESEARCH, 2012, 53 (06) : 954 - 960