Nano X Image Guidance in radiation therapy: feasibility study protocol for cone beam computed tomography imaging with gravity-induced motion

被引:0
|
作者
Debrot, Emily [1 ]
Liu, Paul [1 ]
Gardner, Mark [1 ]
Heng, Soo Min [2 ]
Chan, Chin Hwa [2 ]
Corde, Stephanie [2 ]
Downes, Simon [2 ]
Jackson, Michael [2 ]
Keall, Paul [1 ]
机构
[1] Univ Sydney, ACRF Image Inst 10, Fac Med & Hlth, Camperdown, NSW, Australia
[2] Prince Wales Hosp, Nelune Comprehens Canc Ctr, Randwick, NSW, Australia
基金
澳大利亚国家健康与医学研究理事会; 英国医学研究理事会;
关键词
Image-guided radiotherapy; Image reconstruction; Cone beam CT; RADIOTHERAPY;
D O I
10.1186/s40814-023-01340-z
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
BackgroundThis paper describes the protocol for the Nano X Image Guidance (Nano X IG) trial, a single-institution, clinical imaging study. The Nano X is a prototype fixed-beam radiotherapy system developed to investigate the feasibility of a low-cost, compact radiotherapy system to increase global access to radiation therapy. This study aims to assess the feasibility of volumetric image guidance with cone beam computed tomography (CBCT) acquired during horizontal patient rotation on the Nano X radiotherapy system.MethodsIn the Nano X IG study, we will determine whether radiotherapy image guidance can be performed with the Nano X radiotherapy system where the patient is horizontally rotated while scan projections are acquired. We will acquire both conventional CBCT scans and Nano X CBCT scans for 30 patients aged 18 and above and receiving radiotherapy for head/neck or upper abdomen cancers. For each patient, a panel of experts will assess the image quality of Nano X CBCT scans against conventional CBCT scans. Each patient will receive two Nano X CBCT scans to determine the image quality reproducibility, the extent and reproducibility of patient motion and assess patient tolerance.DiscussionFixed-beam radiotherapy systems have the potential to help ease the current shortfall and increase global access to radiotherapy treatment. Advances in image guidance could facilitate fixed-beam radiotherapy using horizontal patient rotation. The efficacy of this radiotherapy approach is dependent on our ability to image and adapt to motion due to rotation and for patients to tolerate rotation during treatment.
引用
收藏
页数:7
相关论文
共 48 条
  • [21] Principal Component Analysis Based Dynamic Cone Beam X-Ray Luminescence Computed Tomography: A Feasibility Study
    Pu, Huangsheng
    Gao, Peng
    Liu, Yang
    Rong, Junyan
    Shi, Feng
    Lu, Hongbing
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (12) : 2891 - 2902
  • [22] A Personalized Anisotropic Margin for Cervical Cancer Radiation Therapy Under the Guidance of Daily Iterative Cone-Beam Computed Tomography (iCBCT)
    Xiao, Haonan
    Guo, Qiufen
    Ma, Junjie
    Chen, Jian
    Xie, Peng
    Yin, Yong
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (09)
  • [23] Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy
    Paul, Jijo
    Jacobi, Volkmar
    Farhang, Mohammad
    Bazrafshan, Babak
    Vogl, Thomas J.
    Mbalisike, Emmanuel C.
    EUROPEAN RADIOLOGY, 2013, 23 (06) : 1582 - 1593
  • [24] Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy
    Jijo Paul
    Volkmar Jacobi
    Mohammad Farhang
    Babak Bazrafshan
    Thomas J. Vogl
    Emmanuel C. Mbalisike
    European Radiology, 2013, 23 : 1582 - 1593
  • [25] VECTOR ANALYSIS OF PROSTATE PATIENT SETUP WITH IMAGE-GUIDED RADIATION THERAPY VIA KV CONE BEAM COMPUTED TOMOGRAPHY
    Perks, Julian
    Turnbull, Helen
    Liu, Tianxiao
    Purdy, James
    Valicenti, Richard
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (03): : 915 - 919
  • [26] Analysis of motion of the rectum during preoperative intensity modulated radiation therapy for rectal cancer using cone-beam computed tomography
    Yamashita, Hideomi
    Takenaka, Ryousuke
    Sakumi, Akira
    Haga, Akihiro
    Otomo, Kuni
    Nakagawa, Keiichi
    RADIATION ONCOLOGY, 2015, 10
  • [27] Patient setup error and day-to-day esophageal motion error analyzed by cone-beam computed tomography in radiation therapy
    Yamashita, Hideomi
    Haga, Akihiro
    Hayakawa, Yayoi
    Okuma, Kae
    Yoda, Kiyoshi
    Okano, Yukari
    Tanaka, Ken-ichiro
    Imae, Toshikazu
    Ohtomo, Kuni
    Nakagawa, Keiichi
    ACTA ONCOLOGICA, 2010, 49 (04) : 485 - 490
  • [28] A feasibility study for image guided radiotherapy using low dose, high speed, cone beam X-ray volumetric imaging
    Sykes, JR
    Amer, A
    Czajka, J
    Moore, CJ
    RADIOTHERAPY AND ONCOLOGY, 2005, 77 (01) : 45 - 52
  • [29] Evaluation of 4-dimensional Computed Tomography to 4-dimensional Cone-Beam Computed Tomography Deformable Image Registration for Lung Cancer Adaptive Radiation Therapy
    Balik, Salim
    Weiss, Elisabeth
    Jan, Nuzhat
    Roman, Nicholas
    Sleeman, William C.
    Fatyga, Mirek
    Christensen, Gary E.
    Zhang, Cheng
    Murphy, Martin J.
    Lu, Jun
    Keall, Paul
    Williamson, Jeffrey F.
    Hugo, Geoffrey D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (02): : 372 - 379
  • [30] Residual setup error in the canine intracranial region after megavoltage, kilovoltage, or cone-beam computed tomographic image guidance for radiation therapy
    Morimoto, Celina Y.
    Mayer, Monique N.
    Sidhu, Narinder
    Bloomfield, Rachel
    Waldner, Cheryl L.
    VETERINARY AND COMPARATIVE ONCOLOGY, 2020, 18 (02) : 199 - 205