Monte-Carlo simulation for detecting neutron and gamma-ray simultaneously with CdZnTe half-covered by gadolinium film

被引:2
|
作者
Byun, J. [1 ,2 ]
Seo, J. [1 ,2 ]
Kim, Y. [2 ,3 ]
Park, J. [1 ,4 ]
Shin, K. [1 ,4 ]
Lee, W. [4 ,5 ]
Lee, K. [5 ]
Kim, K. [5 ]
Park, B. [1 ,2 ,6 ]
机构
[1] Korea Univ, Dept Hlth & Safety Convergence Sci, Seoul 02841, South Korea
[2] Korea Univ, Interdisciplinary Program Precis Publ Hlth, Seoul 02841, South Korea
[3] Korea Marine Environm Management Corp, Marine Radioact Monitoring Grp, Pusan 48931, South Korea
[4] Korea Univ, Grad Sch, Transdisciplinary Major Learning Hlth Syst, Seoul 02841, South Korea
[5] Korea Univ, Dept Hlth & Environm Sci, Seoul 02841, South Korea
[6] Konkuk Univ, Liquid Crystals Res Ctr, Seoul 05029, South Korea
基金
新加坡国家研究基金会;
关键词
Monte -Carlo simulation; Neutron detection; Prompt gamma-ray; Simultaneous detection; Gadolinium; CdZnTe;
D O I
10.1016/j.net.2022.11.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Neutron is an indirectly ionizing particle without charge, which is normally measured by detecting re-action products. Neutron detection system based on measuring gadolinium-converted gamma-rays is a good way to monitor the neutron because the representative prompt gamma-rays of gadolinium have low energies (79, 89,182, and 199 keV). Low energy gamma-rays and their high attenuation coefficient on materials allow the simple design of a detector easier to manufacture. Thus, we designed a cadmium zinc telluride detector to investigate feasibility of simultaneous detection of gamma-rays and neutrons by using the Monte-Carlo simulation, which was divided into two parts; first was gamma-detection part and second was gamma-and neutron-simultaneous detection part.Consequently, we confirmed that simultaneous detection of gamma-rays and neutrons could be feasible and valid, although further research is needed for adoption on real detection.(c) 2022 Korean Nuclear Society, Published by Elsevier Korea LLC. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:1031 / 1035
页数:5
相关论文
共 25 条
  • [21] Thickness determination of material plates by gamma-ray transmission technique using calibration curves constructed from Monte Carlo simulation
    Huynh Dinh Chuong
    Le Thi Ngoc Trang
    Le Hoang Minh
    Nguyen Thi Truc Linh
    Hoang Duc Tam
    Tran Thien Thanh
    RADIATION PHYSICS AND CHEMISTRY, 2022, 190
  • [22] Analysis of scattered radiation cross-talk in a high-resolution gamma ray tomography detector with GATE Monte-Carlo simulation
    Kiessling, N.
    Bieberle, A.
    Hampel, U.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 595 (02) : 375 - 380
  • [23] The Monte Carlo simulation approach to verification of the attenuation factors k for isotropic gamma-ray sources commonly used in industry, medicine and science
    Blazkiewicz, Marta
    Konefal, Adam
    RADIATION PHYSICS AND CHEMISTRY, 2022, 190
  • [24] Monte Carlo simulation of gamma-ray interactions in an over-square high-purity germanium detector for in-vivo measurements
    Saizu, Mirela Angela
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON APPLICATIONS OF NUCLEAR TECHNIQUES (CRETE15), 2016, 44
  • [25] Monte Carlo simulation of spatial resolution of lens-coupled LYSO scintillator for intense pulsed gamma-ray imaging system with large field of view
    Li, Guoguang
    Sheng, Liang
    Duan, Baojun
    Li, Yang
    Hei, Dongwei
    Xing, Qingzi
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2024, 56 (07) : 2650 - 2658