Monte-Carlo simulation for detecting neutron and gamma-ray simultaneously with CdZnTe half-covered by gadolinium film

被引:2
|
作者
Byun, J. [1 ,2 ]
Seo, J. [1 ,2 ]
Kim, Y. [2 ,3 ]
Park, J. [1 ,4 ]
Shin, K. [1 ,4 ]
Lee, W. [4 ,5 ]
Lee, K. [5 ]
Kim, K. [5 ]
Park, B. [1 ,2 ,6 ]
机构
[1] Korea Univ, Dept Hlth & Safety Convergence Sci, Seoul 02841, South Korea
[2] Korea Univ, Interdisciplinary Program Precis Publ Hlth, Seoul 02841, South Korea
[3] Korea Marine Environm Management Corp, Marine Radioact Monitoring Grp, Pusan 48931, South Korea
[4] Korea Univ, Grad Sch, Transdisciplinary Major Learning Hlth Syst, Seoul 02841, South Korea
[5] Korea Univ, Dept Hlth & Environm Sci, Seoul 02841, South Korea
[6] Konkuk Univ, Liquid Crystals Res Ctr, Seoul 05029, South Korea
基金
新加坡国家研究基金会;
关键词
Monte -Carlo simulation; Neutron detection; Prompt gamma-ray; Simultaneous detection; Gadolinium; CdZnTe;
D O I
10.1016/j.net.2022.11.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Neutron is an indirectly ionizing particle without charge, which is normally measured by detecting re-action products. Neutron detection system based on measuring gadolinium-converted gamma-rays is a good way to monitor the neutron because the representative prompt gamma-rays of gadolinium have low energies (79, 89,182, and 199 keV). Low energy gamma-rays and their high attenuation coefficient on materials allow the simple design of a detector easier to manufacture. Thus, we designed a cadmium zinc telluride detector to investigate feasibility of simultaneous detection of gamma-rays and neutrons by using the Monte-Carlo simulation, which was divided into two parts; first was gamma-detection part and second was gamma-and neutron-simultaneous detection part.Consequently, we confirmed that simultaneous detection of gamma-rays and neutrons could be feasible and valid, although further research is needed for adoption on real detection.(c) 2022 Korean Nuclear Society, Published by Elsevier Korea LLC. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:1031 / 1035
页数:5
相关论文
共 25 条
  • [1] A benchmark for Monte Carlo simulation in gamma-ray spectrometry
    Lepy, M. C.
    Thiam, C.
    Anagnostakis, M.
    Galea, R.
    Gurau, D.
    Hurtado, S.
    Karfopoulos, K.
    Liang, J.
    Liu, H.
    Luca, A.
    Mitsios, I
    Potiriadis, C.
    Savva, M., I
    Thanh, T. T.
    Thomas, V
    Townson, R. W.
    Vasilopoulou, T.
    Zhang, M.
    APPLIED RADIATION AND ISOTOPES, 2019, 154
  • [2] Monte Carlo simulation of gamma-ray response functions for a proportional counter used for neutron measurement
    Takeda, N
    Kudo, K
    Sugita, T
    Dietze, G
    Yang, X
    APPLIED RADIATION AND ISOTOPES, 2000, 53 (4-5) : 893 - 896
  • [3] Monte-carlo simulation of the prompt gamma neutron activation analysis system with a femtosecond laser
    Shim, Hyunha
    Hong, Byungsik
    Lee, Kyong-Sei
    Lee, Sungman
    Cha, Hyungki
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (05) : 702 - 709
  • [4] Monte-carlo simulation of the prompt gamma neutron activation analysis system with a femtosecond laser
    Hyunha Shim
    Byungsik Hong
    Kyong-Sei Lee
    Sungman Lee
    Hyungki Cha
    Journal of the Korean Physical Society, 2012, 61 : 702 - 709
  • [5] Use of Monte Carlo simulation to examine gamma-ray interactions in germanium detectors
    Kamboj, S
    Kahn, B
    RADIATION MEASUREMENTS, 2003, 37 (01) : 1 - 8
  • [6] Characteristic X ray emission in gadolinium following neutron capture as an improved method of in vivo measurement: A comparison between feasibility experiment and Monte-Carlo simulation
    Graefe, J. L.
    McNeill, F. E.
    Chettle, D. R.
    Byun, S. H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2012, 281 : 21 - 25
  • [7] Monte-Carlo simulation of a compact gamma-ray detector using wavelength-shifting fibers coupled to a YAP scintillation crystal
    祝杰
    马红光
    马文彦
    曾晖
    汪兆民
    许咨宗
    中国物理C, 2008, (05) : 377 - 380
  • [8] Monte-Carlo simulation of a compact gamma-ray detector using wavelength-shifting fibers coupled to a YAP scintillation crystal
    Zhu Jie
    Ma Hong-Guang
    Ma Wen-Yan
    Zeng Hui
    Wang Zhao-Min
    Xu Zi-Zong
    CHINESE PHYSICS C, 2008, 32 (05) : 377 - 380
  • [9] Monte Carlo simulation by GEANT 4 and GESPECOR of in situ gamma-ray spectrometry measurements
    Chirosca, Alecsandru
    Suvaila, Rares
    Sima, Octavian
    APPLIED RADIATION AND ISOTOPES, 2013, 81 : 87 - 91
  • [10] Precise Monte Carlo simulation of gamma-ray response functions for an NaI(Tl) detector
    Shi, HX
    Chen, BX
    Li, TZ
    Yun, D
    APPLIED RADIATION AND ISOTOPES, 2002, 57 (04) : 517 - 524