Optimal Degree of Balloon-Expandable Transcatheter Valve Oversizing in Patients With Borderline Aortic Annulus Measurements: Insights From a Multicenter Real-World Experience

被引:6
作者
Panagides, Vassili [2 ]
Cheema, Asim N. [3 ,4 ]
Urena, Marina [5 ]
Nombela-Franco, Luis [6 ]
Veiga-Fernandez, Gabriela [7 ]
Vilalta, Victoria [8 ]
Regueiro, Ander [9 ]
Del Val, David [10 ]
Asmarats, Lluis [11 ]
del Trigo, Maria [12 ]
Serra, Vicenc [13 ]
Munoz-Garcia, Antonio [14 ]
Rezaei, Effat [4 ]
Himbert, Dominique [5 ]
Tirado-Conte, Gabriela [6 ]
Hernandez, Jose M. de la Torre
Fernandez-Nofrerias, Eduard [8 ]
Cepas-Guillen, Pedro L. [9 ]
Alfonso, Fernando [10 ]
Gutierrez-Alonso, Lola [11 ]
Oteo Dominguez, Juan Francisco [12 ]
Belanech, Yassin [13 ]
Paradis, Jean-Michel [2 ]
Mesnier, Jules [2 ]
Rodes-Cabau, Josep [1 ,2 ,9 ]
机构
[1] Laval Univ, Quebec Heart & Lungs Inst, 2725 Chemin Ste Foy, Quebec City, PQ G1V 4GS, Canada
[2] Laval Univ, Quebec Heart & Lung Inst, Quebec City, PQ, Canada
[3] St Michaels Hosp, Toronto, ON, Canada
[4] Southlake Reg Hlth Ctr, Newmarket, ON, Canada
[5] Hop Xavier Bichat, AP HP, Paris, France
[6] Hosp Clin San Carlos, Cardiovasc Inst, Inst Invest Sanitaria, Madrid, Spain
[7] Hosp Marques de Valdecilla, Santander, Spain
[8] Hosp Badalona Germans Trias & Pujol, Dept Cardiol, Badalona, Spain
[9] Clin Barcelona, Barcelona, Spain
[10] Univ Autonoma Madrid, Hosp Univ La Princesa, Dept Cardiol, IIS IP, Madrid, Spain
[11] Hosp Santa Creu & Sant Pau, Cardiol Dept, Barcelona, Spain
[12] Hosp Univ Puerta de Hierro, Serv Cardiol, Madrid, Spain
[13] Hosp Univ Vall dHebron, Vall dHebron Res Inst, Barcelona, Spain
[14] Hosp Reg Univ Virgen de la Victoria, Ctr Invest Biomed Red Enfermedades Cardiovac, Malaga, Spain
关键词
hemodynamics; outcomes; oversizing; paravalvular aortic regurgitation; permanent pacemaker implantation; COMPUTED-TOMOGRAPHY; SAPIEN; 3; IMPLANTATION; REPLACEMENT; REGURGITATION; HEMODYNAMICS; IMPACT; TAVR;
D O I
10.1161/CIRCINTERVENTIONS.122.012554
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background:The potential benefit of using larger or smaller transcatheter heart valves (THV) in patients with borderline aortic annulus measurement (BAM) remains uncertain. The objective of this study was to evaluate the clinical outcomes associated with the selection of larger or smaller THV in the context of BAM. Methods:This was a multicenter observational study including patients who underwent transcatheter aortic valve replacement with the SAPIEN 3 or SAPIEN 3 Ultra-valve systems (Edwards Lifesciences, Irvine, CA) from April 2014 to June 2021. BAM was defined according to the manufacturer sizing chart and included the following annulus areas: 314 to 346, 400 to 430, 500 to 546 mm(2). A 1:1 propensity score matching was used to compare outcomes of patients with larger or smaller THV. Results:From a total of 2467 patients, BAM was identified in 852 patients (34.5%). A larger and smaller THV was selected in 338 (39.7%) and 514 patients (60.3%) patients, respectively. The choice of a larger THV was associated (before and after propensity matching) with a higher risk of new-onset left bundle branch block (HR, 2.25 [95% CI, 1.39-3.65; P=0.001) and permanent pacemaker implantation (HR, 1.86 [95% CI, 1.11-3.09]; P=0.016) without any impact on gradients or the risk of moderate or severe paravalvular regurgitation at discharge (HR, 0.78 [95% CI, 0.41-1.45]; P=0.427). The risk of periprocedural complications such as aortic rupture and tamponade was low (<1%) and similar between groups. Conclusions:In patient with BAM, selecting a larger SAPIEN 3/Ultra THV increased the risk of conduction disturbances without any benefit on valve hemodynamics and clinical outcomes.
引用
收藏
页码:89 / 98
页数:10
相关论文
共 14 条
  • [1] 5-Year Outcomes After TAVR With Balloon -Expandable Versus Self -Expanding Valves
    Abdel-Wahab, Mohamed
    Landt, Martin
    Neumann, Franz-Josef
    Massberg, Steffen
    Frerker, Christian
    Kurz, Thomas
    Kaur, Jatinderjit
    Toelg, Ralph
    Sachse, Susanne
    Jochheim, David
    Schaefer, Ulrich
    El-Mawardy, Mohamed
    Robinson, Derek R.
    Richardt, Gert
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (09) : 1071 - 1082
  • [2] Anatomical and Procedural Features Associated With Aortic Root Rupture During Balloon-Expandable Transcatheter Aortic Valve Replacement
    Barbanti, Marco
    Yang, Tae-Hyun
    Cabau, Josep Rodes
    Tamburino, Corrado
    Wood, David A.
    Jilaihawi, Hasan
    Blanke, Phillip
    Makkar, Raj R.
    Latib, Azeem
    Colombo, Antonio
    Tarantini, Giuseppe
    Raju, Rekha
    Binder, Ronald K.
    Nguyen, Giang
    Freeman, Melanie
    Ribeiro, Henrique B.
    Kapadia, Samir
    Min, James
    Feuchtner, Gudrun
    Gurtvich, Ronen
    Alqoofi, Faisal
    Pelletier, Marc
    Ussia, Gian Paolo
    Napodano, Massimo
    de Brito, Fabio Sandoli
    Kodali, Susheel
    Norgaard, Bjarne L.
    Hansson, Nicolaj C.
    Pache, Gregor
    Canovas, Sergio J.
    Zhang, Hongbin
    Leon, Martin B.
    Webb, John G.
    Leipsic, Jonathon
    [J]. CIRCULATION, 2013, 128 (03) : 244 - 253
  • [3] Computed Tomography Imaging in the Context of Transcatheter Aortic Valve Implantation (TAVI)/Transcatheter Aortic Valve Replacement (TAVR) An Expert Consensus Document of the Society of Cardiovascular Computed Tomography
    Blanke, Philipp
    Weir-McCall, Jonathan R.
    Achenbach, Stephan
    Delgado, Victoria
    Hausleiter, Joerg
    Jilaihawi, Hasan
    Marwan, Mohamed
    Norgaard, Bjarne L.
    Piazza, Niccolo
    Schoenhagen, Paul
    Leipsic, Jonathon A.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2019, 12 (01) : 1 - 24
  • [4] Clinical impact of conduction disturbances in transcatheter aortic valve replacement recipients: a systematic review and meta-analysis
    Faroux, Laurent
    Chen, Shmuel
    Muntane-Carol, Guillem
    Regueiro, Ander
    Philippon, Francois
    Sondergaard, Lars
    Jorgensen, Troels H.
    Lopez-Aguilera, Jose
    Kodali, Susheel
    Leon, Martin
    Nazif, Tamim
    Rodes-Cabau, Josep
    [J]. EUROPEAN HEART JOURNAL, 2020, 41 (29) : 2771 - +
  • [5] Predictors of Permanent Pacemaker Implantations and New-Onset Conduction Abnormalities With the SAPIEN 3 Balloon-Expandable Transcatheter Heart Valve
    Husser, Oliver
    Pellegrini, Costanza
    Kessler, Thorsten
    Burgdorf, Christof
    Thaller, Hannah
    Mayr, N. Patrick
    Kasel, Albert M.
    Kastrati, Adnan
    Schunkert, Heribert
    Hengstenberg, Christian
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (03) : 244 - 254
  • [6] Impact of Annular Oversizing on Paravalvular Regurgitation and Valve Hemodynamics New Insights From PARTNER 3
    Ihdayhid, Abdul Rahman
    Leipsic, Jonathon
    Hahn, Rebecca T.
    Pibarot, Philippe
    Thourani, Vinod
    Makkar, Raj
    Kodali, Susheel
    Russo, Mark
    Kapadia, Samir
    Chen, Yanjun
    Mack, Michael
    Webb, John
    Bax, Jeroen
    Leon, Martin B.
    Blanke, Philipp
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (19) : 2158 - 2169
  • [7] Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document
    Kappetein, A. Pieter
    Head, Stuart J.
    Genereux, Philippe
    Piazza, Nicolo
    van Mieghem, Nicolas M.
    Blackstone, Eugene H.
    Brott, Thomas G.
    Cohen, David J.
    Cutlip, Donald E.
    van Es, Gerrit-Anne
    Hahn, Rebecca T.
    Kirtane, Ajay J.
    Krucoff, Mitchell W.
    Kodali, Susheel
    Mack, Michael J.
    Mehran, Roxana
    Rodes-Cabau, Josep
    Vranckx, Pascal
    Webb, John G.
    Windecker, Stephan
    Serruys, Patrick W.
    Leon, Martin B.
    [J]. EUROPEAN HEART JOURNAL, 2012, 33 (19) : 2403 - +
  • [8] Optimal Oversizing Index Depending on Valve Type and Leakage-Proof Function for Preventing Paravalvular Leakage after Transcatheter Aortic Valve Implantation
    Ki, You-Jeong
    Kang, Jeehoon
    Lee, Hak Seung
    Chang, Mineok
    Han, Jung-Kyu
    Yang, Han-Mo
    Park, Kyung Woo
    Kang, Hyun-Jae
    Koo, Bon-Kwon
    Kim, Hyo-Soo
    [J]. JOURNAL OF CLINICAL MEDICINE, 2020, 9 (12) : 1 - 17
  • [9] Development of a Risk Score to Predict New Pacemaker Implantation After Transcatheter Aortic Valve Replacement
    Kiani, Soroosh
    Kamioka, Norihiko
    Black, George B.
    Lu, Marvin Louis Roy
    Lisko, John C.
    Rao, Birju
    Mengistu, Andenet
    Gleason, Patrick T.
    Stewart, James P.
    Caughron, Hope
    Dong, Andy
    Patel, Hima
    Grubb, Kendra J.
    Greenbaum, Adam B.
    Devireddy, Chandan M.
    Guyton, Robert A.
    Leshnower, Bradley
    Merchant, Faisal M.
    El-Chami, Mikhael
    Westerman, Stacy B.
    Lloyd, Michael S.
    Babaliaros, Vasilis C.
    Hoskins, Michael H.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (21) : 2133 - 2142
  • [10] Effect of Aortic Annulus Size and Prosthesis Oversizing on the Hemodynamics and Leaflet Bending Stress of Transcatheter Valves: An In Vitro Study
    Maleki, Hoda
    Shahriari, Shahrokh
    Labrosse, Michel
    Rodes-Cabau, Josep
    Pibarot, Philippe
    Kadem, Lyes
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2015, 31 (08) : 1041 - 1046