Underfrequency Load Shedding Strategy With an Adaptive Variation Capability for Multi-Microgrids

被引:0
|
作者
Chen, Ran [1 ]
Xu, Hanping [1 ]
Zhou, Li [1 ]
Cai, Jie [1 ]
Xiong, Chuanyu [1 ]
Zhou, Yingbo [1 ]
Zhang, Xuefei [2 ,3 ]
Dong, Qingguo [4 ]
Wang, Can [2 ,3 ]
Yang, Nan [2 ,3 ]
机构
[1] State Grid Hubei Econ Res Inst, Wuhan 430077, Peoples R China
[2] China Three Gorges Univ, Hubei Prov Collaborat Innovat Ctr New Energy Micro, Yichang 443002, Peoples R China
[3] China Three Gorges Univ, Coll Elect Engn & New Energy, Yichang 443002, Peoples R China
[4] State Grid Heze Power Supply Co, Heze 274000, Peoples R China
来源
IEEE ACCESS | 2023年 / 11卷
关键词
Support vector machines; Load modeling; Time-frequency analysis; Load shedding; Power system stability; Adaptation models; Microgrids; Adaptive solution method; comprehensive evaluation; load shedding; microgrid; power shortage; SCHEME;
D O I
10.1109/ACCESS.2023.3246088
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Multi-microgrids (MMGs) suffer from power shortages due to the loss of utility grid support when an unintentional transition occurs. This imposes a transient shock on the system voltage and frequency. To maintain the frequency stability and power balance of an islanded MMG, this paper presents an underfrequency load shedding (UFLS) strategy with adaptive variation. A comprehensive load evaluation method based on a composite least squares support vector machine (CLS-SVM) is proposed to ensure uninterrupted power for critical loads. This method considers the comprehensive evaluation influence factors (CEIFs) of loads. Then, a least squares support vector machine (LS-SVM) provides the load shedding determination factors, transforming the problem of determining critical loads into a 0-1 planning problem. A method with adaptive variation is proposed to solve the UFLS model. The effectiveness of the proposed strategy is verified for an MMG model based on a modified IEEE 33-bus system. The test results show that: 1) the average accuracy of the proposed method is 21.05% higher than that based on LS-SVM; 2) compared with UFLS strategies based on the load level alone and on an intelligent algorithm, the frequency fluctuation range of the proposed strategy is 12.50% and 19.23% lower, respectively, and the frequency recovery time is 3.90% and 5.73% shorter, respectively; 3) compared with PSO, GOA and GA, the standard deviation of the iterative mean of the proposed algorithm decreases by 36.22%, 53.42%, and 34.00%, respectively. The proposed strategy can reduce the frequency fluctuation range and frequency recovery time while maintaining strong adaptability.
引用
收藏
页码:17294 / 17304
页数:11
相关论文
共 50 条
  • [31] An Adaptive Optimization-Based Load Shedding Scheme in Microgrids
    Gholami, Amin
    Shekari, Tohid
    Sun, Xu Andy
    PROCEEDINGS OF THE 51ST ANNUAL HAWAII INTERNATIONAL CONFERENCE ON SYSTEM SCIENCES (HICSS), 2018, : 2660 - 2669
  • [32] Adaptive load shedding scheme for frequency stability enhancement in microgrids
    Marzband, Mousa
    Moghaddam, Maziar Mirhosseini
    Akorede, Mudathir Funsho
    Khomeyrani, Ghazal
    ELECTRIC POWER SYSTEMS RESEARCH, 2016, 140 : 78 - 86
  • [33] Based on adaptive modulation laser communication multi-microgrids scheduling system
    Chang, Ying
    Chang, Dajun
    Su, Li
    FRONTIERS IN PHYSICS, 2023, 11
  • [34] Coordinated Optimal Voltage Control Strategy in Distribution Networks with Multi-Microgrids
    Sun, Xianzhuo
    Zhang, Wen
    2018 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2018,
  • [35] A two-stage underfrequency load shedding strategy for microgrid groups considering risk avoidance
    Wang, Can
    Wang, Zhen
    Chu, Sihu
    Ma, Hui
    Yang, Nan
    Zhao, Zhuoli
    Lai, Chun Sing
    Lai, Loi Lei
    APPLIED ENERGY, 2024, 367
  • [36] A Novel Load Shedding Strategy Combining Undervoltage and Underfrequency with Considering of High Penetration of Wind Energy
    Zhang, Hao-Tian
    Lai, Chun Sing
    Lai, Loi Lei
    Xu, Fangyuan
    2015 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC 2015): BIG DATA ANALYTICS FOR HUMAN-CENTRIC SYSTEMS, 2015, : 659 - 664
  • [37] Multi-microgrids system reliability assessment algorithm considering energy dispatch strategy among microgrids
    Chen, Bo
    Zhang, Xingyou
    Zhang, Bing
    Wang, Liang
    Li, Wenbo
    Wang, Shouxiang
    RENEWABLE ENERGY INTEGRATION WITH MINI/MICROGRID, 2018, 145 : 15 - 19
  • [38] An adaptive approach to setting underfrequency load shedding relays for an isolated power system with private generation
    Lukic, M
    Kuzle, I
    Tesnjak, S
    MELECON '98 - 9TH MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, VOLS 1 AND 2, 1998, : 1122 - 1125
  • [40] Adaptive decentralized fuzzy logic-based underfrequency load shedding to enhance power system stability
    Saboune, Souheil
    Ladjici, Ahmed Amine
    Tiguercha, Ahmed
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2021, 31 (11)