Current-Limiting Reactors Based Time-Domain Fault Location for High-Voltage DC Systems With Hybrid Transmission Corridors

被引:10
|
作者
Nougain, Vaibhav [1 ]
Mishra, Sukumar [1 ]
机构
[1] IIT Delhi, Dept Elect Engn, New Delhi 110016, India
关键词
Fault location; Circuit faults; HVDC transmission; Time-domain analysis; Voltage measurement; Resistance; Transmission line measurements; high-voltage direct current (HVdc) transmission systems; International Council on Large Electric Systems (CIGRE) benchmark; power system fault diagnosis; power system measurements; power system protection; transient analysis; PROTECTION; ALGORITHM; LINES; IDENTIFICATION; CIRCUIT;
D O I
10.1109/TIM.2022.3227610
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Accurately locating the fault distance helps in the rapid restoration of the isolated line back into the system. This article proposes a novel time-domain-based algorithm to determine accurate fault location in high-voltage direct current (HVdc) systems with hybrid dc transmission corridors i.e., a combination of underground cables (UGCs) and overhead lines (OHLs). The work gives a fault location method for a two-segment and three-segment hybrid transmission corridor (HTC) and then generalizes the analysis for an n-segment HTC. The algorithm offers flexibility to locate faults ranging from the homogeneous transmission line to n-segment HTC. The algorithm uses a simplified unit resistance-inductance ( RL ) representation of transmission lines along with time-domain-based measurements i.e., terminal voltage, current, and voltage across current-limiting reactors (CLRs). Power systems computer-aided design/electromagnetic transients including dc (PSCAD/EMTDC)-based simulations are used to validate robust performance against variation of key implementation parameters like type of faults, fault resistance, fault location, sampling frequency, and white Gaussian noise (WGN) in measurement. Further, the fault location calculation is analyzed under parameter variation i.e., change in the true value of unit resistance and unit inductance of line or cable and the true value of dc link capacitance.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Fault location in high-voltage direct-current grids based on panoramic voltage features and vision transformers
    Ren, Bo
    Luo, Yongjie
    Zhou, Niancheng
    Wang, Qianggang
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 158
  • [32] Virtual synchronous generator based pole control in high-voltage DC transmission systems
    Hirase, Yuko
    Takeda, Tomoya
    Ohuchi, Kazuki
    ENERGY REPORTS, 2022, 8 : 1073 - 1084
  • [33] Time-domain finite volume method for ion-flow field analysis of bipolar high-voltage direct current transmission lines
    Yin, H.
    Zhang, B.
    He, J.
    Zeng, R.
    Li, R.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2012, 6 (08) : 785 - 791
  • [34] Single-ended Protection Scheme of Flexible DC Transmission Lines Based on Concavity and Convexity of the Current-limiting Reactor Voltage Integration
    Jia K.
    Chen M.
    Shi Z.
    Chen C.
    Zhao G.
    Bi T.
    Dianwang Jishu/Power System Technology, 2021, 45 (11): : 4498 - 4504
  • [35] Artificial Neural Network-based Fault Location in Terminal-hybrid High Voltage Direct Current Transmission Lines
    Hadaeghi, A.
    Iliyaeifar, M. M.
    Chirani, A. Abdollahi
    INTERNATIONAL JOURNAL OF ENGINEERING, 2023, 36 (02): : 215 - 225
  • [36] Accurate Fault Location Method Based on Time-Domain Information Estimation for Medium-Voltage Distribution Network
    Sun, Guanqun
    Chen, Rusi
    Han, Zheyu
    Liu, Haiguang
    Liu, Meiyuan
    Zhang, Ke
    Xu, Chaozheng
    Wang, Yikai
    ELECTRONICS, 2023, 12 (23)
  • [37] Phasor-based fault location challenges and solutions for transmission lines equipped with high-speed time-domain protective relays
    Lopes, Felipe, V
    Leite Jr, Eduardo Jorge S.
    Ribeiro, Joao Paulo G.
    Piardi, Artur B.
    Fabian Espinoza, Renzo G.
    Scheid, Allan, V
    Zat, Guilherme
    Otto, Rodrigo B.
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 189 (189)
  • [38] Hybrid High-voltage Direct-current Transmission System Based on Unidirectional Current Modular Multilevel Converter
    Yang W.
    Song Q.
    Liu W.
    Xu S.
    Rao H.
    Zhu Z.
    Gaodianya Jishu/High Voltage Engineering, 2018, 44 (07): : 2205 - 2212
  • [39] A new fault location method for high-voltage transmission lines based on ICEEMDAN-MSA-ConvGRU model
    Jia, Taorong
    Yao, Lixiao
    Yang, Guoqing
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2024, 18 (16) : 2650 - 2668
  • [40] Time-Domain Protection and Fault Location of Wye-Connected Shunt Capacitor Banks Using Superimposed Current and Differential Voltage
    Mohanty, Rabindra
    Pradhan, Ashok Kumar
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (06) : 3486 - 3495