Flexural Integrity Between the Individual Channels of Built-Up Cold-Formed Steel Beams

被引:2
|
作者
Suhaib, Mir Basar [1 ]
Tantray, Manzoor Ahmad [1 ]
机构
[1] Natl Inst Technol Srinagar, Dept Civil Engn, Srinagar, India
关键词
Cold-formed steel; Back-to-back channels; Built-up beam; Flexural strength; Screw connection; Composite action; DOUBLE-Z MEMBERS; DESIGN; SECTIONS; STRENGTH; BEHAVIOR;
D O I
10.1007/s13296-023-00708-4
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigates the influence of commonly used screw connections on the integrity of built-up beams formed by connecting two lipped channel sections in a back-to-back configuration. An experimental investigation on the behaviour of 6 built-up CFS beams connected by self-drilling screws is presented in this paper. The screw spacing was varied along the length as well as the depth of the beams. The test results indicate that the screw spacing has some influence on the capacity of the built-up beams. An increase in screw spacing leads to an undesirable separation of channels and thus has a negative impact on the composite action between the members. Finite element models were developed and after successful validation, a parametric study involving 124 models was carried out, to investigate the impact of larger longitudinal screw spacings on the integral behaviour of the beams. It was observed that the flexural capacity decreased by 11%, 14%, 17% and 19% when the longitudinal distance between the screws increased from 50 to 1050 mm for beams with web depths 150 mm, 200 mm, 250 mm and 300 mm respectively. It can be concluded that flexural capacity is directly proportional to the decrease in the screw spacing and increase in the number of screw rows. The results also indicate that the percentage decrease in strength is greater for beams with larger web depths. An idealized cross section assuming complete composite action was simulated for each web depth using FE modelling and the capacities of all the screw-connected "semi-rigid " beams were compared against it. The capacity of screw connected built-up beams with web depths 150 mm, 200 mm, 250 mm and 300 mm was found to be 0.71, 0.64, 0.61 and 0.59 times that of the idealized cross-section on average, respectively. The moment capacities of screw-connected beams were also compared against the theoretical values obtained from AISI S-100. It was observed that the design guidelines provided in AISI S-100 were unable to account for the reduction in the moment capacity due to the screw connection in built-up members. AISI S-100 is conservative by as much as 34%, 42%, 46% and 48% for beams with web depths 150 mm, 200 mm, 250 mm and 300 mm respectively.
引用
收藏
页码:503 / 520
页数:18
相关论文
共 50 条
  • [31] Experimental investigation of the sectional buckling of built-up cold-formed steel columns
    Abbasi, Mandana
    Rasmussen, Kim J. R.
    Khezri, Mani
    Schafer, Benjamin W.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 203
  • [32] Flexural behaviour of back-to-back built-up cold-formed steel channel beams: Experiments and finite element modelling
    Roy, Krishanu
    Lau, Hieng Ho
    Ting, Tina Chui Huon
    Chen, Boshan
    Lim, James B. P.
    STRUCTURES, 2021, 29 : 235 - 253
  • [33] Study on the flexural behavior of corroded built-up cold-formed thin-walled steel beams
    Zhang, Zongxing
    Xu, Shanhua
    Li, Han
    Li, Rou
    Nie, Biao
    STEEL AND COMPOSITE STRUCTURES, 2020, 37 (03) : 353 - 369
  • [34] Flexural Strength Behaviour of Bolted Built-Up Cold-Formed Steel Beam with Outstand and Extended Stiffener
    Muftah, Fadhluhartini
    Sani, Mohd Syahrul Hisyam Mohd
    Kamal, Mohd Mawardi Mohd
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2019, 19 (03) : 719 - 732
  • [35] Flexural capacity of gapped built-up cold-formed steel channel sections including web stiffeners
    Roy, Krishanu
    Lau, Hieng Ho
    Tina Chui Huon Ting
    Chen, Boshan
    Lim, James B. P.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 172 (172)
  • [36] Mechanical Performance of Built-Up Columns Composed of Four Cold-Formed Square Steel Tubes
    Chen, Xiaomiao
    Xia, Junwu
    Xu, Bo
    Ma, Renwei
    APPLIED SCIENCES-BASEL, 2019, 9 (06):
  • [37] Experimental investigation on laser welded connections for built-up cold-formed steel beams
    Landolfo, R.
    Mammana, O.
    Portioli, F.
    Di Lorenzo, G.
    Guerrieri, M. R.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (01) : 196 - 208
  • [38] Behaviour and design of cold-formed high-strength steel built-up beams
    Kumar, S. Kavin
    Anbarasu, M.
    Sonkar, Chanchal
    THIN-WALLED STRUCTURES, 2024, 202
  • [39] Experimental and Numerical Study on the Flexural Behavior of Cold-Formed Steel Multi-Limb Built-Up Section Beams
    Deng, Feiyun
    He, Yulong
    Deng, Lu
    Zhong, Wenjie
    BUILDINGS, 2022, 12 (10)
  • [40] Post fire flexural behavior of mild steel based cold-formed built-up beams exposed to elevated temperature
    Sam, Varun Sabu
    Anand, N.
    Abdallah, Mirvat
    Hachem, Chady Ei
    Azab, Marc
    Andrushia, Diana
    FRONTIERS IN BUILT ENVIRONMENT, 2024, 10