Experimental demonstration of real-time cardiac physiology-based radiotherapy gating for improved cardiac radioablation on an MR-linac

被引:4
|
作者
Akdag, Osman [1 ,4 ]
Borman, Pim T. S. [1 ]
Mandija, Stefano [1 ,2 ]
Woodhead, Peter L. [1 ,3 ]
Uijtewaal, Prescilla [1 ]
Raaymakers, Bas W. [1 ]
Fast, Martin F. [1 ,4 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiotherapy, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Computat Imaging Grp MR Diagnost & Therapy, Ctr Image Sci, Utrecht, Netherlands
[3] Elekta AB, Stockholm, Sweden
[4] Univ Med Ctr Utrecht, Dept Radiotherapy, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands
基金
荷兰研究理事会;
关键词
cardiac radioablation; gating; MR-linac; MAGNETIC-RESONANCE; CATHETER ABLATION; EXPERT CONSENSUS; RADIATION; HEART; STATEMENT; WORKFLOW; MOTION;
D O I
10.1002/mp.17024
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundCardiac radioablation is a noninvasive stereotactic body radiation therapy (SBRT) technique to treat patients with refractory ventricular tachycardia (VT) by delivering a single high-dose fraction to the VT isthmus. Cardiorespiratory motion induces position uncertainties resulting in decreased dose conformality. Electocardiograms (ECG) are typically used during cardiac MRI (CMR) to acquire images in a predefined cardiac phase, thus mitigating cardiac motion during image acquisition.PurposeWe demonstrate real-time cardiac physiology-based radiotherapy beam gating within a preset cardiac phase on an MR-linac.MethodsMR images were acquired in healthy volunteers (n = 5, mean age = 29.6 years, mean heart-rate (HR) = 56.2 bpm) on the 1.5 T Unity MR-linac (Elekta AB, Stockholm, Sweden) after obtaining written informed consent. The images were acquired using a single-slice balance steady-state free precession (bSSFP) sequence in the coronal or sagittal plane (TR/TE = 3/1.48 ms, flip angle = 48 circle$<^>{\circ }$, SENSE = 1.5, field-of-view=400x207$\text{field-of-view} = {400}\times {207}$ mm2${\text{mm}}<^>{2}$, voxel size = 3x3x15$3\times 3\times 15$ mm3${\rm mm}<^>{3}$, partial Fourier factor = 0.65, frame rate = 13.3 Hz). In parallel, a 4-lead ECG-signal was acquired using MR-compatible equipment. The feasibility of ECG-based beam gating was demonstrated with a prototype gating workflow using a Quasar MRI4D motion phantom (IBA Quasar, London, ON, Canada), which was deployed in the bore of the MR-linac. Two volunteer-derived combined ECG-motion traces (n = 2, mean age = 26 years, mean HR = 57.4 bpm, peak-to-peak amplitude = 14.7 mm) were programmed into the phantom to mimic dose delivery on a cardiac target in breath-hold. Clinical ECG-equipment was connected to the phantom for ECG-voltage-streaming in real-time using research software. Treatment beam gating was performed in the quiescent phase (end-diastole). System latencies were compensated by delay time correction. A previously developed MRI-based gating workflow was used as a benchmark in this study. A 15-beam intensity-modulated radiotherapy (IMRT) plan (1x6.25${1}\times {6.25}$ Gy) was delivered for different motion scenarios onto radiochromic films. Next, cardiac motion was then estimated at the basal anterolateral myocardial wall via normalized cross-correlation-based template matching. The estimated motion signal was temporally aligned with the ECG-signal, which were then used for position- and ECG-based gating simulations in the cranial-caudal (CC), anterior-posterior (AP), and right-left (RL) directions. The effect of gating was investigated by analyzing the differences in residual motion at 30, 50, and 70% treatment beam duty cycles.ResultsECG-based (MRI-based) beam gating was performed with effective duty cycles of 60.5% (68.8%) and 47.7% (50.4%) with residual motion reductions of 62.5% (44.7%) and 43.9% (59.3%). Local gamma analyses (1%/1 mm) returned pass rates of 97.6% (94.1%) and 90.5% (98.3%) for gated scenarios, which exceed the pass rates of 70.3% and 82.0% for nongated scenarios, respectively. In average, the gating simulations returned maximum residual motion reductions of 88%, 74%, and 81% at 30%, 50%, and 70% duty cycles, respectively, in favor of MRI-based gating. ConclusionsReal-time ECG-based beam gating is a feasible alternative to MRI-based gating, resulting in improved dose delivery in terms of high gamma-pass$\gamma {\text{-pass}}$ rates, decreased dose deposition outside the PTV and residual motion reduction, while by-passing cardiac MRI challenges.
引用
收藏
页码:2354 / 2366
页数:13
相关论文
共 26 条
  • [21] Non-Invasive Plasmonic-Based Real-Time Characterization of Cardiac Drugs on Cardiomyocytes Functional Behavior
    Mozneb, Maedeh
    Mirza, Asad M.
    Li, Chen-Zhong
    ANALYTICAL CHEMISTRY, 2020, 92 (02) : 2244 - 2250
  • [22] Real-time cardiac MRI using an undersampled spiral k-space trajectory and a reconstruction based on a variational network
    Kleineisel, Jonas
    Heidenreich, Julius F.
    Eirich, Philipp
    Petri, Nils
    Koestler, Herbert
    Petritsch, Bernhard
    Bley, Thorsten A.
    Wech, Tobias
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (05) : 2167 - 2178
  • [23] Initial clinical experience of Stereotactic Body Radiation Therapy (SBRT) for liver metastases, primary liver malignancy, and pancreatic cancer with 4D-MRI based online adaptation and real-time MRI monitoring using a 1.5 Tesla MR-Linac
    Hal, William A.
    Straza, Michael W.
    Chen, Xinfeng
    Mickevicius, Nikolai
    Erickson, Beth
    Schultz, Chris
    Awan, Musaddiq
    Ahunbay, Ergun
    Li, X. Allen
    Paulson, Eric S.
    PLOS ONE, 2020, 15 (08):
  • [24] SNR enhancement of highly-accelerated real-time cardiac MRI acquisitions based on non-local means algorithm
    Naegel, Benoit
    Cernicanu, Alexandru
    Hyacinthe, Jean-Noel
    Tognolini, Maurizio
    Vallee, Jean-Paul
    MEDICAL IMAGE ANALYSIS, 2009, 13 (04) : 598 - 608
  • [25] High-Resolution Functional Cardiac MR Imaging using Density-Weighted Real-Time Acquisition and a Combination of Compressed Sensing and Parallel Imaging for Image Reconstruction
    Wech, T.
    Gutberlet, M.
    Greiser, A.
    Staeb, D.
    Ritter, C. O.
    Beer, M.
    Hahn, D.
    Koestler, H.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (08): : 676 - 681
  • [26] Feasibility of free-breathing, GRAPPA-based, real-time cardiac cine assessment of left-ventricular function in cardiovascular patients at 3T
    Zhu, Xiaomei
    Schwab, Felix
    Marcus, Roy
    Hetterich, Holger
    Theisen, Daniel
    Kramer, Harald
    Notohamiprodjo, Mike
    Schlett, Christopher L.
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Bamberg, Fabian
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (05) : 849 - 855