A study on quality control check of dose distribution in blood bags irradiated by 137Cs source blood irradiator by using EBT3 radiochromic film dosimetry

被引:4
作者
Alan, Hatice Yilmaz [1 ]
Unal, Gokberk [1 ]
Atakul, Tugba [2 ]
Akyurek, Serap [2 ]
Yucel, Haluk [1 ]
机构
[1] Ankara Univ, Inst Nucl Sci, TR-06100 Ankara, Turkiye
[2] Ankara Univ, Cebeci Hosp, Fac Med, Dept Radiat Oncol, TR-06100 Ankara, Turkiye
关键词
Transfusion-associated graft-versus-host dis-ease (TA-GVHD); 137Cs blood irradiator; EBT3 radiochromic film dosimetry; Dose mapping; MCNPX; PHOTON; COMPONENTS; SCANNER;
D O I
10.1016/j.radphyschem.2023.111303
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this study, the dose homogeneity in the blood bags delivered by a137Cs blood irradiator is investigated by using EBT3 radiochromic film dosimetry. The dose delivered to blood bags is an important factor for protection to TA-GVHD patients during transfusion in medicine. To do this, the dose results experimentally determined by EBT3 films were then compared with those of a MCNPX simulation in which the irradiation canister containing the blood bags was irradiated with a MSD Gammacell 3000 Elan. In the simulation, two different irradiation situations were modeled; one is the canister full with blood bags and the other is half-full of blood bags. The simulation dose results showed that when the canister was filled fully with blood bags, a dose of 24.4 +/- 0.1 Gy was estimated in the canister center line. When the canister was half-full with the bags, a 28.8 +/- 0.1 Gy dose was estimated in the canister center line. Whereas the dose of 31.3 +/- 0.6 Gy dose was experimentally determined in the canister center line when the canister was filled (3 blood bags) half full. As a result, the dose homogeneity in the irradiated blood bags can easily checked by means of a two-dimensional EBT3 film dosimetry technique. Hence, this study showed that EBT3 film dosimetry is still powerful method for quality control check of dose homogeneity of any blood bags before it was used in patient.
引用
收藏
页数:10
相关论文
共 41 条
[1]  
Andreo P, 2006, IAEA TECHNICAL REPOR, V398
[2]  
[Anonymous], US
[3]  
[Anonymous], Perfection V800 Photo/V850 Pro User's Guide
[4]  
[Anonymous], 2008, Gammacell 3000Elan Technical Specifications Brochur
[5]  
[Anonymous], 2009, IRR TECHN H 315 SESS
[6]  
BEVINGTON PR, 1992, DATA REDUCTION ERROR
[7]   Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification [J].
Borca, Valeria Casanova ;
Pasquino, Massimo ;
Russo, Giuliana ;
Grosso, Pierangelo ;
Cante, Domenico ;
Sciacero, Piera ;
Girelli, Giuseppe ;
La Porta, Maria Rosa ;
Tofani, Santi .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (02) :158-171
[8]  
Boucher S., 2013, P IPAC2013 SHANGH CH
[9]   Radiochromic Films for the Two-Dimensional Dose Distribution Assessment [J].
Casolaro, Pierluigi .
APPLIED SCIENCES-BASEL, 2021, 11 (05) :1-16
[10]   Probability Distribution of Pixel Intensities of EBT3 Films and its Application in the Correction of Uncertainty Budget [J].
Chaudhary, Rahul Kumar ;
Pathan, Munir ;
Kumar, Rajesh ;
Sharma, S. D. ;
Sapra, B. K. .
JOURNAL OF MEDICAL PHYSICS, 2021, 46 (01) :26-32