Standardized reduction and palmar plating of dorsally displaced distal radius fractures for safe and atraumatic reconstruction of the anatomy of the radius

被引:0
|
作者
Loew, Steffen [1 ,2 ]
Kiesel, Sebastian [1 ]
机构
[1] Praxis Handchirurgie & Unfallchirurgie, Bad Mergentheim, Germany
[2] Praxis Handchirurg & Unfallchirurg, Ledermarkt 8-10, D-97080 Bad Mergentheim, Germany
来源
OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE | 2024年 / 36卷 / 3-4期
关键词
Distal radius fracture; Reduction quality; Radial inclination; Standardization; Ulnar variance;
D O I
10.1007/s00064-023-00838-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: Standardization of palmar plate osteosynthesis in order to consequently achieve physiologic anatomy of the distal radius end.IndicationsUnstable dorsally displaced distal radius fractures or fractures that should be treated functionally.Contraindications: Severe intraarticular joint depression that cannot be reduced with either a palmar or arthroscopic assisted approach.Surgical technique: Patient in supine position with the forearm supinated on arm table. Radiopalmar incision along the radial border of the flexor carpi radialis tendon. Detachment of the pronator quadratus muscle from radial to ulnar. Gross reduction with eventual correction of a dorsal or radial shift. Placement of the angular stable plate and preliminary fixation with a nonangular stable cortical screw in the long hole at the radius shaft. Fluoroscopic control of axial alignment in the anteroposterior view and of correct distal position of the plate in the lateral view under reduction condition. Placement of one or two angular stable screws at the shaft. Under subtle reduction with flexion, ulnar deviation and axial traction placement of two K-wires via the holes at the distal edge of the plate. These wires mostly keep reduction maintained while reduction maneuver can be paused. Fluoroscopic control in two planes. Replacement of the wires by distal angular stable screws with the help of the wires as an orientation. In case of insufficient reduction, reduction maneuver can be repeated while the first angular stable screw is locked. Final fluoroscopic control in two planes and ulnar deviation, eventually also in tangential view and clinical testing for stability of the distal radioulnar joint. Wound closure only by skin suture. Application of a sterile dressing and a palmar cast.Postoperative management: Arm consequently in upright position and active and complete movement of fingers. Palmar below-elbow cast for 2 weeks, then movement of wrist without exertion. After regular radiographic control 4-5 weeks postoperatively, increase of axial load to normal and, if needed, physiotherapy. Clinical control for irritation of tendons by plate or screws after 1 year and eventual plate removal.
引用
收藏
页码:223 / 234
页数:12
相关论文
共 50 条
  • [1] Palmar plating for dorsally displaced fractures of the distal radius
    Kamano, M
    Honda, Y
    Kazuki, K
    Yasuda, M
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (397) : 403 - 408
  • [2] Standardisierte Reposition und palmare Plattenosteosynthese dorsal dislozierter distaler Radiusfrakturen zur sicheren und atraumatischen Wiederherstellung der RadiusanatomieStandardized reduction and palmar plating of dorsally displaced distal radius fractures for safe and atraumatic reconstruction of the anatomy of the radius
    Steffen Löw
    Sebastian Kiesel
    Operative Orthopädie und Traumatologie, 2024, 36 (3-4) : 223 - 234
  • [3] Palmar plating with the locking compression plate for dorsally displaced fractures of the distal radius -: First clinical experiences
    Schütz, M
    Kolbeck, S
    Spranger, A
    Arndt-Kolbeck, M
    Haas, NP
    ZENTRALBLATT FUR CHIRURGIE, 2003, 128 (12): : 997 - 1002
  • [4] LOCKING PALMAR PLATE FIXATION FOR DORSALLY DISPLACED FRACTURES OF THE DISTAL RADIUS: A PRELIMINARY REPORT
    Moriya, Koji
    Saito, Hidehiko
    Takahashi, Yuji
    Ohi, Hiroyuki
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2011, 16 (03): : 363 - 369
  • [5] Fixation of Dorsally Displaced Distal Radius Fractures With Volar Plate
    Othman, Ahmed Y.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (05): : 1416 - 1420
  • [6] Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius
    Rozental, TD
    Blazar, PE
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (03): : 359 - 365
  • [7] PALMAR FIXATION OF DORSALLY DISPLACED DISTAL RADIUS FRACTURES USING LOCKING PLATES WITH SMARTLOCK LOCKING SCREWS
    Wong, T. C.
    Yeung, C. C.
    Chiu, Y.
    Yeung, S. H.
    Ip, F. K.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2009, 34E (02) : 173 - 178
  • [8] Where Is the Distal Fracture Line Location of Dorsally Displaced Distal Radius Fractures?
    Baumbach, Sebastian Felix
    Schmidt, Reinhard
    Varga, Peter
    Heinz, Thomas
    Vecsei, Vilmos
    Zysset, Philippe K.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2011, 29 (04) : 489 - 494
  • [9] Volar neutralization plate fixation of dorsally displaced distal radius fractures
    Constantine, KJ
    Clawson, MC
    Stern, PJ
    ORTHOPEDICS, 2002, 25 (02) : 125 - 128
  • [10] Volar fixation for dorsally displaced fractures of the distal radius: A preliminary report
    Orbay, JL
    Fernandez, DL
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2002, 27A (02): : 205 - 215