Using PRIMO to determine the initial beam parameters of Elekta Synergy linac for electron beam energies of 6, 9, 12, and 15 MeV

被引:1
|
作者
Rezzoug, Mohammed [1 ]
Zerfaoui, Mustapha [1 ]
Oulhouq, Yassine [1 ]
Rrhioua, Abdeslem [1 ]
机构
[1] Mohammed First Univ, Fac Sci, LPMR, Oujda Angad, Morocco
关键词
PRIMO Code; Elekta Synergy; Monte Carlo simulation; linac; electron beam; MONTE-CARLO-SIMULATION; PHOTON; ALGORITHM; DOSIMETRY;
D O I
10.5603/rpor.96865
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: The purpose of this research was to establish the primary electron beam characteristics for an Elekta Synergy linear accelerator. In this task, we take advantage of the PRIMO Monte Carlo software, where the model developed contains the majority of the component materials of the Linac. Materials and methods: For all energies, the Elekta Linac electron mode and 14 x 14 cm(2) applicator were chosen. To obtain percentage depth dose (PDD) curves, a homogeneous water phantom was voxelized in a 1 x 1 x 0.1 cm(3) grid along the central axis. At the reference depth, the dose profile was recorded in 0.1 x 1 x 1 cm(3) voxels. Iterative changes were made to the initial beams mean energy and full width at half maximum (FWHM) of energy in order to keep the conformity of the simulated and measured dose curves within. To confirm simulation results, the Gamma analysis was performed with acceptance criteria of 2 mm - 2%. From the validated calculation, the parameters of the PDD and profile curve (R100, R50, Rp, and field size) were collected. Results: Initial mean energies of 7.3, 9.85, 12.9, and 15.7 MeV were obtained for nominal energies of 6, 9, 12, and 15, respectively. The PRIMO Monte Carlo model for Elekta Synergy was precisely validated. Conclusions: PRIMO is an easy-to-use software program that can calculate dose distribution in water phantoms.
引用
收藏
页码:592 / 600
页数:9
相关论文
共 6 条
  • [1] A multivariate approach to determine electron beam parameters for a Monte Carlo 6 MV Linac model: Statistical and machine learning methods
    Yang, Hye Jeong
    Kim, Tae Hoon
    Schaarschmidt, Thomas
    Park, Dong-Wook
    Kang, Seung Hee
    Chung, Hyun-Tai
    Suh, Tae Suk
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 93 : 38 - 45
  • [2] Simulation of a 6 MV Elekta Precise Linac photon beam using GATE/GEANT4
    Grevillot, L.
    Frisson, T.
    Maneval, D.
    Zahra, N.
    Badel, J-N
    Sarrut, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (04) : 903 - 918
  • [4] Monte carlo calculation of the energy spectrum of a 6 MeV electron beam using penetration and energy loss of positrons and electrons code
    Apaza Veliz, Danny Giancarlo
    Wilches Visbal, Jorge Homero
    Chen Abrego, Felipe
    Vega Ramirez, Jose Luis
    JOURNAL OF MEDICAL PHYSICS, 2020, 45 (02) : 116 - 122
  • [5] Monte Carlo investigation of the effect of small cutouts on beam profile parameters of 12 and 14 MeV electron beams
    Khaledi, Navid
    Arbabi, Azim
    Sardari, Dariush
    Mandavi, Seied Rabie
    Aslian, Hossein
    Dabaghi, Moloud
    Sheibani, Kourosh
    RADIATION MEASUREMENTS, 2013, 51-52 : 48 - 54