Hyperarc Vmat and Vmat planning for stereotactic radiosurgery in multiple brain metastases

被引:3
作者
Celen, Yonca Yahsi [1 ]
Dinc, Ozcan [2 ]
Arslan, Nazmiye Deniz [3 ]
Dag, Sedef [2 ]
Dogan, Ayse Kutluhan [2 ]
Gunenc, Senar [2 ]
机构
[1] Balikesir Univ, Fac Med, Biophys Dept, Balikesir, Turkiye
[2] Yedikule Chest Dis Training & Res Hosp, Dept Pathol, Istanbul, Turkiye
[3] IAU VM Med Pk Florya Hosp, Dept Radiat Oncol, Istanbul, Turkiye
关键词
Volumetric modulated arc therapy (VMAT); HyperArc (HA-VMAT); Stereotactic radiosurgery (SRS); Dosimetric comparison; VOLUMETRIC MODULATED ARC; LINEAR-ACCELERATOR; THERAPY; RADIOTHERAPY; CONFORMITY; MANAGEMENT; ISOCENTER; QUALITY; IMRT;
D O I
10.1016/j.jrras.2023.100719
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Automated treatment planning systems are available for linear accelerator (LINAC) based single and more isocenter multitarget stereotactic radiosurgery (SRS) of brain metastases. HyperArc Volumetric Modulated Arc Therapy (HA-VMAT) is a relatively new isocentric Volumetric Modulated Arc Therapy (VMAT) technique developed specifically for non-coplanar, multileaf collimator (MLC)-based stereotactic radiotherapy with automatic treatment optimization and dose delivery. The HA-VMAT planning approach was developed to accom-modate dosing procedures for brain metastases stereotactic radiosurgery. In this study, it was aimed to compare the dosimetric parameters of treatment plans created with single and multi-isocenter retrospectively VMAT and HA-VMAT techniques in patients with lung cancer and multiple brain metastases (4-7) who received single and multi-fraction stereotactic radiosurgery (SRS). Using VMAT and HA-VMAT techniques, two separate treatment plans were created for each case, and tumor target coverage (homogeneity index (HI); conformity index (CI); gradient index (GI)) and organ at risk (OAR) were evaluated dosimetrically. Physical properties and Monitor unit (MU) values of both treatment approaches were compared. Treatment plans were created for study purposes and patients were not treated with these plans. In the study, HI (p = 0.000), CI (p = 0.000) and GI (p = 0.002) values calculated with the HA-VMAT technique are superior to the VMAT technique. Medium-low dose spreads (V4Gy-V16Gy) were significantly reduced in HA-VMAT plans compared to plans with VMAT. HA-VMAT plans result in lower MU than VMAT plans. HA-VMAT planning has significantly less radiation necrosis indicator (V8Gy-V16Gy) compared to VMAT plans. However, there are few studies investigating the ability of the HA-VMAT technique to create high-quality treatment plans for extracranial lesions. HA-VMAT may constitute one of the new options for SRS dose delivery for both single target and multiple targets.
引用
收藏
页数:8
相关论文
共 46 条
[1]   Dosimetric characterization of CyberKnife® robotic SRS using MOSFET-based "MOskin" detector [J].
Alhujaili, Sultan Fahad ;
Alafer, Feras ;
Alshabibi, Abdulaziz Saad A. ;
Alrowaili, Ziyad Awadh ;
Almeshari, Meshari ;
Al Kafi, M. A. ;
Aldosari, A. H. ;
Alshaikh, Sami ;
Moftah, Belal .
JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2023, 16 (04)
[2]   Technical Note: Collimator angle optimization for multiple brain metastases in dynamic conformal arc treatment planning [J].
Battinelli, Cecilia ;
Fredriksson, Albin ;
Eriksson, Kjell .
MEDICAL PHYSICS, 2021, 48 (09) :5414-5422
[3]   IRRADIATED VOLUME AS A PREDICTOR OF BRAIN RADIONECROSIS AFTER LINEAR ACCELERATOR STEREOTACTIC RADIOSURGERY [J].
Blonigen, Brian J. ;
Steinmetz, Ryan D. ;
Levin, Linda ;
Lamba, Michael A. ;
Warnick, Ronald E. ;
Breneman, John C. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (04) :996-1001
[4]   Effect of Radiosurgery Alone vs Radiosurgery With Whole Brain Radiation Therapy on Cognitive Function in Patients With 1 to 3 Brain Metastases A Randomized Clinical Trial [J].
Brown, Paul D. ;
Jaeckle, Kurt ;
Ballman, Karla V. ;
Farace, Elana ;
Cerhan, Jane H. ;
Anderson, S. Keith ;
Carrero, Xiomara W. ;
Barker, Fred G., II ;
Deming, Richard ;
Burri, Stuart H. ;
Menard, Cynthia ;
Chung, Caroline ;
Stieber, Volker W. ;
Pollock, Bruce E. ;
Galanis, Evanthia ;
Buckner, Jan C. ;
Asher, Anthony L. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (04) :401-409
[5]   Neurocognition in patients with brain metastases treated with radiosurgery or radiosurgery plus whole-brain irradiation: a randomised controlled trial [J].
Chang, Eric L. ;
Wefel, Jeffrey S. ;
Hess, Kenneth R. ;
Allen, Pamela K. ;
Lang, Frederick F. ;
Kornguth, David G. ;
Arbuckle, Rebecca B. ;
Swint, J. Michael ;
Shiu, Almon S. ;
Maor, Moshe H. ;
Meyers, Christina A. .
LANCET ONCOLOGY, 2009, 10 (11) :1037-1044
[6]   FEASIBILITY OF SINGLE-ISOCENTER VOLUMETRIC MODULATED ARC RADIOSURGERY FOR TREATMENT OF MULTIPLE BRAIN METASTASES [J].
Clark, Grant M. ;
Popple, Richard A. ;
Young, P. Edward ;
Fiveash, John B. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (01) :296-302
[7]  
Enis T., 2021, Acta Scientific Medical Sciences, P12
[8]  
Halasz L. M., 2013, Surgical Neurology International, V4
[9]   CONFORMITY OF LINAC-BASED STEREOTACTIC RADIOSURGERY USING DYNAMIC CONFORMAL ARCS AND MICRO-MULTILEAF COLLIMATOR [J].
Hazard, Lisa J. ;
Wang, Brian ;
Skidmore, Thomas B. ;
Chern, Shyh-Shi ;
Salter, Bill J. ;
Jensen, Randy L. ;
Shrieve, Dennis C. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (02) :562-570
[10]   Feasibility of single-isocenter, multi-arc non-coplanar volumetric modulated arc therapy for multiple brain tumors using a linear accelerator with a 160-leaf multileaf collimator: a phantom study [J].
Iwai, Yoshio ;
Ozawa, Shuichi ;
Ageishi, Tatsuya ;
Pellegrini, Roberto ;
Yoda, Kiyoshi .
JOURNAL OF RADIATION RESEARCH, 2014, 55 (05) :1015-1020