Alternating Look-Locker for quantitative T1, T1? and B1 3D MRI mapping

被引:0
|
作者
Wu, Lin [1 ,2 ]
Carchi, Chris [1 ,2 ]
Michaeli, Shalom [1 ,2 ]
Mangia, Silvia [1 ,2 ]
Idiyatullin, Djaudat [1 ,2 ,3 ]
机构
[1] Univ Minnesota Med Sch, Ctr Magnet Resonance Res, Minneapolis, MN USA
[2] Univ Minnesota Med Sch, Dept Radiol, Minneapolis, MN USA
[3] Univ Minnesota, Ctr MR Res, Radiol Dept, Minneapolis, MN 55455 USA
关键词
B1-map; Look-Locker; rat brain; SWIFT; T-1; T-1 & rho; zero-TE; MAGNETIZATION-TRANSFER; ADIABATIC PULSES; SPIN-LOCKING; RELAXATION; RESONANCE; PHASE; REDUCTION; ARTIFACTS; CONTRAST; BRAIN;
D O I
10.1002/mrm.29839
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a new MRI method, entitled alternating Look-Locker (aLL), for quantitative T-1, T-1?, and B-1 3D mapping.Methods: A Look-Locker scheme that alternates magnetization from +Z and -Z axes of the laboratory frame is utilized in combination with a 3D Multi-Band Sweep Imaging with Fourier Transformation (MB-SWIFT) readout. The analytical solution describing the spin evolution during aLL, as well as the correction required for segmented acquisition were derived. The simultaneous B-1 and T-1 mapping are demonstrated on an agar/saline phantom and on an in-vivo rat head. T-1? relaxation was achieved by cyclically applying magnetization preparation (MP) modules consisting of two adiabatic pulses. T-1? values in the rat brain in-vivo and in a gadobenate dimeglumine (Gd-DTPA) phantom were compared to those obtained with a previously introduced steady-state (SS) method.Results: The accuracy and precision of the analytical solution was tested by Bloch simulations. With the application of MP modules, the aLL method provides simultaneous T(1 )and T-1? maps. Conversely, without it, the method can be used for simultaneous T-1 and B-1 mapping. T-1? values were similar with both aLL and SS techniques. However, the aLL method resulted in more robust quantita-tive mapping compared to the SS method. Unlike the SS method, the aLL method does not require additional scans for generating T-1 maps.Conclusion: The proposed method offers a new flexible tool for quantitative map-ping of T-1, T-1?, and B-1. The aLL method can also be used with readout schemes different from MB-SWIFT.
引用
收藏
页码:149 / 161
页数:13
相关论文
共 50 条
  • [31] Accelerated 2D radial Look-Locker T1 mapping using a deep learning-based rapid inversion recovery sampling technique
    Ahanonu, Eze
    Goerke, Ute
    Johnson, Kevin
    Toner, Brian
    Martin, Diego R.
    Deshpande, Vibhas
    Bilgin, Ali
    Altbach, Maria
    NMR IN BIOMEDICINE, 2024, 37 (12)
  • [32] A Unified Maximum Likelihood Framework for Simultaneous Motion and T1 Estimation in Quantitative MR T1 Mapping
    Ramos-Llorden, Gabriel
    den Dekker, Arnold J.
    Van Steenkiste, Gwendolyn
    Jeurissen, Ben
    Vanhevel, Floris
    Van Audekerke, Johan
    Verhoye, Marleen
    Sijbers, Jan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (02) : 433 - 446
  • [33] Brain Metabolites B1-Corrected Proton T1 Mapping in the Rhesus Macaque at 3 T
    Liu, Songtao
    Fleysher, Roman
    Fleysher, Lazar
    Joo, Chan-Gyu
    Ratai, Eva-Maria
    Gonzalez, R. Gilberto
    Gonen, Oded
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (04) : 865 - 871
  • [34] A Model for Hepatic Fibrosis: The Competing Effects of Cell Loss and Iron on Shortened Modified Look-Locker Inversion Recovery T1 (shMOLLI-T1) in the Liver
    Tunnicliffe, Elizabeth M.
    Banerjee, Rajarshi
    Pavlides, Michael
    Neubauer, Stefan
    Robson, Matthew D.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (02) : 450 - 462
  • [35] Magnetization transfer explains most of the T1 variability in the MRI literature
    Asslander, Jakob
    Flassbeck, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2025,
  • [36] Comparison of T1 mapping and fixed T1 method for dynamic contrast-enhanced MRI perfusion in brain gliomas
    Conte, G. M.
    Altabella, L.
    Castellano, A.
    Cuccarini, V.
    Bizzi, A.
    Grimaldi, M.
    Costa, A.
    Caulo, M.
    Falini, A.
    Anzalone, N.
    EUROPEAN RADIOLOGY, 2019, 29 (07) : 3467 - 3479
  • [37] Saturation pulse design for quantitative myocardial T1 mapping
    Chow, Kelvin
    Kellman, Peter
    Spottiswoode, Bruce S.
    Nielles-Vallespin, Sonia
    Arai, Andrew E.
    Salerno, Michael
    Thompson, Richard B.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
  • [38] Saturation pulse design for quantitative myocardial T1 mapping
    Kelvin Chow
    Peter Kellman
    Bruce S. Spottiswoode
    Sonia Nielles-Vallespin
    Andrew E. Arai
    Michael Salerno
    Richard B. Thompson
    Journal of Cardiovascular Magnetic Resonance, 17
  • [39] Comparison of T1 mapping and fixed T1 method for dynamic contrast-enhanced MRI perfusion in brain gliomas
    G. M. Conte
    L. Altabella
    A. Castellano
    V. Cuccarini
    A. Bizzi
    M. Grimaldi
    A. Costa
    M. Caulo
    A. Falini
    N. Anzalone
    European Radiology, 2019, 29 : 3467 - 3479
  • [40] Repeatability and robustness of MP-GRASP T1 mapping
    Li, Zhitao
    Xu, Xiang
    Yang, Yang
    Feng, Li
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (05) : 2271 - 2286