Alternating Look-Locker for quantitative T1, T1? and B1 3D MRI mapping

被引:0
|
作者
Wu, Lin [1 ,2 ]
Carchi, Chris [1 ,2 ]
Michaeli, Shalom [1 ,2 ]
Mangia, Silvia [1 ,2 ]
Idiyatullin, Djaudat [1 ,2 ,3 ]
机构
[1] Univ Minnesota Med Sch, Ctr Magnet Resonance Res, Minneapolis, MN USA
[2] Univ Minnesota Med Sch, Dept Radiol, Minneapolis, MN USA
[3] Univ Minnesota, Ctr MR Res, Radiol Dept, Minneapolis, MN 55455 USA
关键词
B1-map; Look-Locker; rat brain; SWIFT; T-1; T-1 & rho; zero-TE; MAGNETIZATION-TRANSFER; ADIABATIC PULSES; SPIN-LOCKING; RELAXATION; RESONANCE; PHASE; REDUCTION; ARTIFACTS; CONTRAST; BRAIN;
D O I
10.1002/mrm.29839
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a new MRI method, entitled alternating Look-Locker (aLL), for quantitative T-1, T-1?, and B-1 3D mapping.Methods: A Look-Locker scheme that alternates magnetization from +Z and -Z axes of the laboratory frame is utilized in combination with a 3D Multi-Band Sweep Imaging with Fourier Transformation (MB-SWIFT) readout. The analytical solution describing the spin evolution during aLL, as well as the correction required for segmented acquisition were derived. The simultaneous B-1 and T-1 mapping are demonstrated on an agar/saline phantom and on an in-vivo rat head. T-1? relaxation was achieved by cyclically applying magnetization preparation (MP) modules consisting of two adiabatic pulses. T-1? values in the rat brain in-vivo and in a gadobenate dimeglumine (Gd-DTPA) phantom were compared to those obtained with a previously introduced steady-state (SS) method.Results: The accuracy and precision of the analytical solution was tested by Bloch simulations. With the application of MP modules, the aLL method provides simultaneous T(1 )and T-1? maps. Conversely, without it, the method can be used for simultaneous T-1 and B-1 mapping. T-1? values were similar with both aLL and SS techniques. However, the aLL method resulted in more robust quantita-tive mapping compared to the SS method. Unlike the SS method, the aLL method does not require additional scans for generating T-1 maps.Conclusion: The proposed method offers a new flexible tool for quantitative map-ping of T-1, T-1?, and B-1. The aLL method can also be used with readout schemes different from MB-SWIFT.
引用
收藏
页码:149 / 161
页数:13
相关论文
共 50 条
  • [1] A fast 3D Look-Locker method for volumetric T1 mapping
    Henderson, E
    McKinnon, G
    Lee, TY
    Rutt, BK
    MAGNETIC RESONANCE IMAGING, 1999, 17 (08) : 1163 - 1171
  • [2] Rapid 3D T1 mapping using deep learning-assisted Look-Locker inversion recovery MRI
    Pei, Haoyang
    Xia, Ding
    Xu, Xiang
    Yang, Yang
    Wang, Yao
    Liu, Fang
    Feng, Li
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (02) : 569 - 582
  • [3] Fast T1 mapping of the brain at high field using Look-Locker and
    Jiang, Ke
    Zhu, Yanjie
    Jia, Sen
    Wu, Yin
    Liu, Xin
    Chung, Yiu-Cho
    MAGNETIC RESONANCE IMAGING, 2017, 36 : 49 - 55
  • [4] Accuracy of T1 measurement with 3-D Look-Locker technique for dGEMRIC
    Li, Wei
    Scheidegger, Rachel
    Wu, Ying
    Vu, Anthony
    Prasad, Pottumarthi V.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (03) : 678 - 682
  • [5] Rapid T1 Mapping of Mouse Myocardium With Saturation Recovery Look-Locker Method
    Li, Wen
    Griswold, Mark
    Yu, Xin
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (05) : 1296 - 1303
  • [6] An improved 3-D Look-Locker imaging method for T1 parameter estimation
    Nkongchu, K
    Santyr, G
    MAGNETIC RESONANCE IMAGING, 2005, 23 (07) : 801 - 807
  • [7] Flexible cardiac T1 mapping using a modified look-locker acquisition with saturation recovery
    Song, Ting
    Stainsby, Jeffrey A.
    Ho, Vincent B.
    Hood, Maureen N.
    Slavin, Glenn S.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (03) : 622 - 627
  • [8] Phase-encoding strategies for optimal spatial resolution and T1 accuracy in 3D Look-Locker imaging
    Nkongehu, Ken
    Santyr, Giles
    MAGNETIC RESONANCE IMAGING, 2007, 25 (08) : 1203 - 1214
  • [9] Modified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart
    Messroghli, DR
    Radjenovic, A
    Kozerke, S
    Higgins, DM
    Sivananthan, MU
    Ridgway, JP
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) : 141 - 146
  • [10] A novel method for simultaneous 3D B1 and T1 mapping: the method of slopes (MoS)
    Chavez, Sofia
    Stanisz, Greg J.
    NMR IN BIOMEDICINE, 2012, 25 (09) : 1043 - 1055