Improvement in Intraoperative Image Quality in Transcranial Magnetic Resonance-Guided Focused Ultrasound Surgery Using Transmitter Gain Adjustment

被引:0
|
作者
Hori, Hiroki [1 ]
Yamada, Yusuke [2 ]
Nakano, Masayuki [3 ]
Ouchi, Takahiro [4 ]
Takasaki, Masahito [5 ]
Iijima, Ken [6 ]
Taira, Takaomi [7 ]
Abe, Keiichi [7 ]
Iwamuro, Hirokazu [8 ]
机构
[1] Moriyama Neurosurg Ctr Hosp, Dept FUS Ctr, Tokyo, Japan
[2] Hokkaido Ohno Mem Hosp, Dept Radiol, Sapporo, Japan
[3] Shin Yurigaoka Gen Hosp, Dept Neurosurg, Kawasaki, Japan
[4] Shin Yurigaoka Gen Hosp, Dept Neurol, Kawasaki, Japan
[5] Shin Yurigaoka Gen Hosp, Dept Anesthesiol, Kawasaki, Japan
[6] Saitama Sekishinkai Hosp, Dept Diagnost Radiol, Saitama, Japan
[7] Tokyo Womens Med Univ, Dept Neurosurg, Tokyo, Japan
[8] Juntendo Univ, Dept Neurosurg, Tokyo, Japan
关键词
Essential tremor; Flip angle; magnetic resonance imaging; Stereotactic thalamotomy; Transcranial magnetic resonance-guided focused ultrasound surgery; Transmitter gain; TO-NOISE RATIOS; B-1; INHOMOGENEITY; PULSE; MRI; THALAMOTOMY; TREMOR;
D O I
10.1159/000531009
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Introduction: Transcranial magnetic resonance-guided focused ultrasound surgery (TcMRgFUS) has the advantage of allowing immediate evaluation of therapeutic effects after each sonication and intraoperative magnetic resonance imaging (MRI) to visualize the lesion. When the image shows that the lesion has missed the planned target and the therapeutic effects are insufficient, the target of the subsequent ablation can be finely adjusted based on the image. The precision of this adjustment is determined by the image quality. However, the current intraoperative image quality with a 3.0T MRI system is insufficient for precisely detecting the lesion. Thus, we developed and validated a method for improving intraoperative image quality. Methods: Because intraoperative image quality is affected by transmitter gain (TG), we acquired T2-weighted images (T2WIs) with two types of TG: the automatically adjusted TG (auto TG) and the manually adjusted TG (manual TG). To evaluate the character of images with 2 TGs, the actual flip angle (FA), the image uniformity, and the signal-to-noise ratio (SNR) were measured using a phantom. Then, to assess the quality of intraoperative images, T2WIs with both TGs were acquired during TcMRgFUS for 5 patients. The contrast-to-noise ratio (CNR) of the lesion was retrospectively estimated. Results: The images of the phantom with the auto TG showed substantial variations between the preset and actual FAs (p < 0.01), whereas on the images with the manual TG, there were no variations between the two FAs (p > 0.05). The total image uniformity was considerably lower with the manual TG than with the auto TG (p < 0.01), indicating that the image's signal values with the manual TG were more uniform. The manual TG produced significantly higher SNRs than the auto TG (p < 0.01). In the clinical study, the lesions were clearly detected in intraoperative images with the manual TG, but they were difficult to identify in images with the auto TG. The CNR of lesions in images with manual TG was considerably higher than in images with auto TG (p < 0.01). Conclusion: Regarding intraoperative T2WIs using a 3.0T MRI system during TcMRgFUS, the manual TG method improved image quality and delineated the ablative lesion more clearly than the current method with auto TG.
引用
收藏
页码:223 / 231
页数:9
相关论文
共 50 条
  • [31] Techniques, Indications, and Outcomes in Magnetic Resonance-guided Focused Ultrasound Thalamotomy for Tremor
    Maesawa, Satoshi
    Nakatsubo, Daisuke
    Tsugawa, Takahiko
    Kato, Sachiko
    Shibata, Masashi
    Takai, Sou
    Torii, Jun
    Ishizaki, Tomotaka
    Wakabayashi, Toshihiko
    Saito, Ryuta
    NEUROLOGIA MEDICO-CHIRURGICA, 2021, 61 (11) : 629 - 639
  • [32] Magnetic Resonance-Guided Focused Ultrasound Thalamotomy to Treat Essential Tremor in Nonagenarians
    Paff, Michelle
    Boutet, Alexandre
    Neudorfer, Clemens
    Elias, Gavin J. B.
    Germann, Jurgen
    Loh, Aaron
    Kucharczyk, Walter
    Fasano, Alfonso
    Schwartz, Michael L.
    Lozano, Andres M.
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2020, 98 (03) : 182 - 186
  • [33] ExAblate® magnetic resonance-guided focused ultrasound system in multiple body applications
    Dick, E. A.
    Gedroyc, W. M. W.
    EXPERT REVIEW OF MEDICAL DEVICES, 2010, 7 (05) : 589 - 597
  • [34] Focused ultrasound using a novel targeting method four-tract tractography for magnetic resonance-guided high-intensity focused ultrasound targeting
    Feltrin, Fabricio S.
    Chopra, Rajiv
    Pouratian, Nader
    Elkurd, Mazen
    El-Nazer, Rasheda
    Lanford, Lauren
    Dauer, William
    Shah, Bhavya R.
    BRAIN COMMUNICATIONS, 2022, 4 (06)
  • [35] Feasibility of Magnetic Resonance-Compatible Accelerometers to Monitor Tremor Fluctuations During Magnetic Resonance-Guided Focused Ultrasound Thalamotomy: Technical Note
    Baek, Hongchae
    Chen, Jacqueline
    Lockwood, Daniel
    Obusez, Emmanuel
    Poturalski, Matthew
    Nagel, Sean J.
    Jones, Stephen E.
    OPERATIVE NEUROSURGERY, 2023, 24 (06) : 641 - 650
  • [36] Magnetic Resonance-Guided Focused Ultrasound Treatment for Essential Tremor: A Single-Center Experience
    Hvingelby, Victor S.
    Kjeldsen, Pernille
    Bergholt, Bo
    Schechtmann, Gaston Andres
    Danielsen, Erik Hvid
    Moller, Mette
    Johnsen, Erik Lisbjerg
    Mardosiene, Skirmante
    Lund, Torben Ellegaard
    Grauballe, Dora
    Geneser, Michael
    Sorensen, Tina Vincens
    Bak, Lisa ostergaard
    Andreasen, Martin
    Andersen, Anne Sofie Moller
    Andersen, Lone
    Meier, Kaare
    Juhl, Niels
    Tankisi, Alp
    Jespersen, Bo
    Eriksen, Christian Fenger
    Rasmussen, Mads
    Eriksen, Winnie Bechmann
    Barrutia, Birgitte
    Kromann, Mette
    Baandrup, Ida
    Bjorn, Jette
    Stjernholm, Rie
    Braemer-Madsen, Charlotte
    Jorgensen, Signe Mygdal
    Sorensen, Jens Christian Hedemann
    Glud, Andreas Norgaard
    MOVEMENT DISORDERS CLINICAL PRACTICE, 2025,
  • [37] Early results of magnetic resonance-guided focused ultrasound surgery of adenomyosis: Analysis of 20 cases
    Fukunishi, Hidenobu
    Funaki, Kaoru
    Sawada, Katsuhiro
    Yamaguchi, Kayo
    Maeda, Tetsuo
    Kaji, Yasushi
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2008, 15 (05) : 571 - 579
  • [38] French first results using magnetic resonance-guided focused ultrasound for myoma treatment
    Marret, H.
    Bleuzen, A.
    Guerin, A.
    Lauvin-Gaillard, M. -A.
    Herbreteau, D.
    Patat, F.
    Tranquart, F.
    GYNECOLOGIE OBSTETRIQUE & FERTILITE, 2011, 39 (01): : 12 - 20
  • [39] Magnetic Resonance-Guided Focused Ultrasound Surgery: Part 2: A Review of Current and Future Applications
    Medel, Ricky
    Monteith, Stephen J.
    Elias, W. Jeffrey
    Eames, Matthew
    Snell, John
    Sheehan, Jason P.
    Wintermark, Max
    Jolesz, Ferenc A.
    Kassell, Neal F.
    NEUROSURGERY, 2012, 71 (04) : 755 - 763
  • [40] Spontaneous Vaginal Expulsion of Uterine Myoma after Magnetic Resonance-Guided Focused Ultrasound Surgery
    Kim, Kyoung Ah
    Yoon, Sang-Wook
    Yoon, Bo Sung
    Park, Chong Taik
    Kim, Sang Heum
    Lee, Jong Tae
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2011, 18 (01) : 131 - 134