Experimental validation of fuzzy type-2 against type-1 scheme applied in DC/DC converter integrated to a PEM fuel cell system

被引:3
|
作者
Napole, Cristian [1 ]
Derbeli, Mohamed [1 ]
Barambones, Oscar [1 ]
机构
[1] Basque Country Univ UPV EHU, Dept Syst Engn & Automation, Engn Sch Vitoria, Vitoria 1006, Araba, Spain
关键词
fuzzy control; fuzzy logic; fuzzy set; PEMFC; renewable energies; sliding mode control; VOLTAGE CONTROL; MANAGEMENT;
D O I
10.1002/ese3.1355
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This research presents and compares the outcomes of experimental implementations of different fuzzy logic control structures for a proton exchange membrane fuel cell (PEMFC). These devices are well known for their capability to transform chemical energy into electrical with low emissions. Commonly, a PEMFC has a linkage with a boost converter which allows a suitable end-user voltage through a nonlinear control law. Hence, the contribution in this sense is the experimental comparison of two fuzzy logic strategies known as type-1 and type-2 that were implemented in a PEMFC system. The approaches were embedded in a control board dSPACE 1102 which also has the capability to acquire data. The contrast of results showed capabilities improvement against disturbances in terms of error reduction, control signal, and robustness.
引用
收藏
页码:699 / 710
页数:12
相关论文
共 9 条