共 42 条
Design and performance optimization of a novel zigzag channeled solar photovoltaic thermal system: Numerical investigation and parametric analysis
被引:35
作者:
Attia, Mohammed El Hadi
[1
]
Zayed, Mohamed E.
[2
]
Kabeel, A. E.
[3
,4
,5
]
Khelifa, Abdelkrim
[6
]
Arici, Muslum
[7
]
Abdelgaied, Mohamed
[3
]
机构:
[1] Univ El Oued, Fac Exact Sci, Dept Phys, El Oued 39000, Algeria
[2] King Fahd Univ Petr & Minerals, Interdisciplinary Res Ctr Sustainable Energy Syst, Dhahran, Saudi Arabia
[3] Tanta Univ, Fac Engn, Mech Power Engn Dept, Tanta, Egypt
[4] Delta Univ Sci & Technol, Fac Engn, Gamasa, Egypt
[5] Islamic Univ Madinah, Dept Mech Engn, Medina 42351, Saudi Arabia
[6] Ctr Dev Energies Renouvelables, Unite Rech Appl Energies Renouvelables, URAER, CDER, Ghardaia 47133, Algeria
[7] Kocaeli Univ, Engn Fac, Mech Engn Dept, TR-41001 Kocaeli, Turkiye
关键词:
Photovoltaics;
Numerical investigation;
Design optimization;
Zigzag channeled structures;
Comparative parametric analysis;
Performance enhancement;
CLIMATIC CONDITIONS;
ENERGY;
ENHANCEMENT;
COLLECTOR;
MODULE;
EFFICIENCY;
ABSORBER;
D O I:
10.1016/j.jclepro.2023.140220
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
In order to overcome the drawbacks of traditional photovoltaic thermal systems, including their limited thermal power, low thermal exergy, and heat transfer fluid outlet temperature, it becomes essential to explore the optimal design configuration of the system for maximization both electricity and domestic hot water generation. Therefore, a detailed numerical modeling and comparative performance analysis on a solar photovoltaic thermal collector (PVT) are conducted under two novel structures of the cooling channels. The first system is a reference PVT collector with a classical straight zigzag-plated tube cooling channel (Case A), while the second PVT system proposes an innovative design of flow cooling channel which is divided into three equal zigzag-plated tube sections (Case B). Each section is also split into three double pass tubes and has a separate inlet and outlet in a staggered manner corresponding to the section that precedes and follows it. The two proposed PVT structures are investigated through computational fluid dynamic simulation under solar radiation values ranging from 200 to 1000 W/m2 and coolant flow rates varying between 0.001 and 0.005 kg/s using both water and air as coolant. The obtained results confirm the significant potential of the modified configuration (Case B) that yielded an improvement in the thermal efficiency by 7.23% and 15.75% for water-PVT and air-PVT system, respectively, over the reference PVT system (Case A). Also, the modified configuration (Case B) yielded an enhancement in the electrical efficiency by 4.0% and 4.6% for water-PVT and air-PVT systems, respectively. It can be concluded that dividing the cooling channel area into equally mini zigzag plate tube-shaped sections with multiple reciprocal entrances is regarded a feasible configuration for augmenting the performance of PVT collectors and maintaining a uniform coolant flow and reduced temperature distribution over the entire panel.
引用
收藏
页数:16
相关论文