The Dynamic Response Characteristics of a Water Transmission Pipe Crossing a Loess Fault Using a Large-Scale Shaking Table Test: A Case Study

被引:2
作者
Deng, Longsheng [1 ,2 ,3 ]
Chen, Jiale [1 ]
Fan, Wen [1 ,2 ,4 ]
Li, Yubo [5 ,6 ]
Shi, Linpeng [1 ]
机构
[1] ChangAn Univ, Sch Geol Engn & Geomat, Xian 710054, Peoples R China
[2] Mine Geol Disasters Mech & Prevent Key Lab, Xian 710054, Peoples R China
[3] Lanzhou Univ, Coll Civil Engn & Mech, Lanzhou 730000, Peoples R China
[4] China Elect Res Inst Engn Invest & Design, Xian 710054, Peoples R China
[5] China Railway First Survey & Design Inst Grp Co Lt, Xian 710043, Peoples R China
[6] Shaanxi Railway & Underground Traff Engn Key Lab F, Xian, Peoples R China
基金
中国国家自然科学基金;
关键词
Large-scale shaking table test; Pipeline crossing a fault zone; Saturated loess site; Loess liquefaction and seismic collapse; BURIED PIPELINE; SEISMIC DESIGN; EARTHQUAKE; BEHAVIOR; LANDSLIDES; TUNNELS; CHINA; AREA;
D O I
10.1061/IJGNAI.GMENG-8604
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Loess is a typical structural soil with properties such as water sensitivity, collapsibility, and seismic vulnerability. The dynamic response of a water transmission pipe crossing a fault zone is highly complex in a loess site. The Hanjiang River to the Weihe River Diversion Project (Phase II) crossing the Weihe fault was selected as the prototype for a shaking table test, through which the responses of acceleration, dynamic stresses, strains, and pore-water pressure were systematically investigated. The acceleration response of a geologic body similar to the experimental model was greatly affected by factors such as fault location, degree of soil saturation, distribution of internal structure, and so on. The acceleration along elevation experienced its highest amplification factor of approximately 2.0, mainly due to seismic waves with frequencies above 2.0 Hz being amplified. To ensure the seismic fortification of the pipeline near the fault belt, it is recommended to utilize an acceleration of 1.2 times within the severe impact zone. This zone involved 36.0 m of the hanging wall and 30.0 m of the footwall, which are approximately 6.0 times and 5.0 times of the fault belt width. It is recommended to use an acceleration of 1.1 times for areas within 200 m from the fault of the hanging wall; refer to the fault-avoiding distance of the seismic design code. The deformation mode of the water pipeline was expansion/shrinkage in the transverse section and slight bending in the longitudinal section. The pore-water pressure response demonstrated coupling features of hysteresis, accumulation, and dissipation. The seismic collapsibility modes of the loess at the studied site were generalized into four stages: energy accumulation, state mutation, failure extension, and successive failure. Seismic subsidence could be expressed by adopting a piecewise function with a maximum value of approximately 18.0 cm. Based on the similarity calculation, the maximum seismic subsidence of the prototype can be recommended as 3.6 m. Liquefaction occurred when the input acceleration amplitude reached 0.5g. These shaking table test results provided reasonable parameters for the seismic design and construction of the Hanjiang to Weihe River Diversion Project across this fault.
引用
收藏
页数:17
相关论文
共 21 条
  • [21] Dynamic Response Characteristics of Railway Subgrade Using a Newly-Developed Prestressed Reinforcement Structure: Case Study of a Model Test
    Zhang, Qishu
    Leng, Wuming
    Dong, Junli
    Xu, Fang
    MATERIALS, 2022, 15 (19)