The effects of the first versus second glaucoma drainage implant surgery in patients with primary open-angle glaucoma

被引:2
作者
Morita, Shuu [1 ]
Hamanaka, Teruhiko [2 ]
Sakurai, Tetsuro [3 ]
Watanabe, Satoshi [1 ]
Sakanishi, Yoshihito [1 ]
Ishida, Nobuo [4 ]
Ebihara, Nobuyuki [1 ]
机构
[1] Juntendo Univ, Urayasu Hosp, Dept Ophthalmol, Chiba, Japan
[2] Japanese Red Cross Med Ctr, Dept Ophthalmol, 4-1-22,Hiroo,Shibuya Ku, Tokyo 1568935, Japan
[3] Suwa Univ Sci, Sch Gen & Management Studies, Nagano, Japan
[4] Ishida Eye Clin, Niigata, Japan
关键词
The first/second glaucoma-drainage-implant; Primary open-angle glaucoma; DIODE-LASER CYCLOPHOTOCOAGULATION; AHMED GLAUCOMA; INTRAOCULAR-PRESSURE; ENDOSCOPIC CYCLOPHOTOCOAGULATION; SEQUENTIAL GLAUCOMA; ENDOTHELIAL-CELLS; SHUNT SURGERY; RISK-FACTORS; TUBE; DEVICE;
D O I
10.1186/s12886-023-03247-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background To investigate the outcome of non-valved glaucoma drainage implant surgery (GDIS) in primary open-angle glaucoma (POAG) patients divided in the first GDI group (patients who underwent the first GDIS) and the second GDI group (patients who underwent the second GDIS because of the failed first GDIS).Methods Intraocular pressure (IOP), visual acuity (VA), visual field defect (VFD), medication score (MS), survival rate of GDIS, complications, and patient background was retrospectively analyzed. Two success criteria were set: Criteria (1) IOP reduction >= 20% and 5 < IOP <= 21, Criteria (2) IOP reduction >= 20% and 5 < IOP <= 14.Results There were 136 eyes of 109 patients in the first GDI group and 32 eyes of 27 patients in the second GDI group. In the first GDI group and II, mean preoperative IOP was 26.7 +/- 6.7 mmHg and 23.7 +/- 3.5 mmHg, respectively (P = 0.09). No statistically significant difference in postoperative IOP reduction was found between the two groups (P = 0.39). At 5-years postoperative, the Criteria 1 (Criteria 2) survival rate in the first GDI group and the second GDI group was 60.4% (31.7%) and 61.2% (25.6%), respectively (Criteria 1: hazard ratio [HR]: 0.64, 95% confidence interval [CI]: 0.30-1.35 [P = 0.24]; Criteria 2: HR: 0.81, 95% CI: 0.46-1.44, P = 0.48). No significant difference in VA, VFD change, MS, or complications was observed. Young patient age was the only significant factor for failure in the first GDI group (odds ratio: 0.95, 95% confidence interval: 0.91-1.00, P = 0.03).Conclusion The second GDIS may be as effective as the first GDIS for IOP reduction in POAG patients, however, there is a high risk of failure in young-age patients and the surgery may be ineffective in eyes requiring Criteria 2.
引用
收藏
页数:11
相关论文
共 48 条
[41]   Supplemental transscleral diode laser cyclophotocoagulation after aqueous shunt placement in refractory glaucoma [J].
Semchyshyn, TM ;
Tsai, JC ;
Joos, KK .
OPHTHALMOLOGY, 2002, 109 (06) :1078-1084
[42]   Shunt revision versus additional tube shunt implantation after failed tube shunt surgery in refractory glaucoma [J].
Shah, AA ;
WuDunn, D ;
Cantor, LB .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (04) :455-460
[43]   Corneal endothelial cell loss after Baerveldt glaucoma drainage device implantation in the anterior chamber [J].
Tan, Annelie N. ;
Webers, Carroll A. B. ;
Berendschot, Tos T. J. M. ;
de Brabander, John ;
de Witte, Pauline M. ;
Nuijts, Rudy M. M. A. ;
Schouten, Johannes S. A. G. ;
Beckers, Henny J. M. .
ACTA OPHTHALMOLOGICA, 2017, 95 (01) :91-96
[44]  
Van Veldhuisen PC, 2000, AM J OPHTHALMOL, V130, P429
[45]   Comparison of Efficacy and Complications of Cyclophotocoagulation and Second Glaucoma Drainage Device After Initial Glaucoma Drainage Device Failure [J].
Wang, Margaret Y. ;
Patel, Kishan ;
Blieden, Lauren S. ;
Chuang, Alice Z. ;
Baker, Laura A. ;
Bell, Nicholas P. ;
Feldman, Robert M. .
JOURNAL OF GLAUCOMA, 2017, 26 (11) :1010-1018
[46]   Evaluation of the outcome of long-tube shunt implant surgery in uveitic glaucoma patients by analyzing the background of uveitis [J].
Watanabe, Satoshi ;
Hamanaka, Teruhiko ;
Sakurai, Tetsuro ;
Kobayashi, Kanae ;
Ishida, Nobuo ;
Ebihara, Nobuyuki .
INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (02) :509-517
[47]   A Meta-analysis on the Outcome of Sequential Glaucoma Drainage Implantation [J].
Yoon, Dan ;
Vajaranant, Thasarat .
JOURNAL OF GLAUCOMA, 2020, 29 (03) :184-190
[48]   The Effect of Tube Location on Corneal Endothelial Cells in Patients with Ahmed Glaucoma Valve [J].
Zhang, Qi ;
Liu, Yingna ;
Thanapaisal, Sukhumal ;
Oatts, Julius ;
Luo, Yetao ;
Ying, Gui-Shuang ;
Wang, Junming ;
McLeod, Stephen D. ;
Gedde, Steven J. ;
Han, Ying .
OPHTHALMOLOGY, 2021, 128 (02) :218-226