Impedance-Based Short Circuit-Short Circuit Fault Location Method in Coaxial Cables

被引:1
|
作者
Bugajska, Aneta [1 ]
Desaniuk, Tomasz [2 ]
机构
[1] Kielce Univ Technol, Fac Elect Engn Automat Control & Comp Sci, PL-25314 Kielce, Poland
[2] Kielce Univ Technol, Fac Mechatron & Mech Engn, PL-25314 Kielce, Poland
关键词
Input impedance; transverse impedance; distance to the fault location; coaxial cable; diagnostic tests; SCHEME; WAVE;
D O I
10.1109/ACCESS.2023.3320641
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The paper presents the results of the assessment and verification of a non-destructive method of fault location in coaxial cables with a local weakening of insulation. The essence of the method is to measure the input impedance of the cable in a short circuit at both ends and, based on obtained values, to determine the transverse impedance of the fault and the distance to the fault location. For the RG59 Cable with a length of 50.0 m, with the assumed distance to the fault location of 5.0 m, for the short circuit-short circuit method, the error in determining the fault location is from 0.0 m to 1.8 m, for open circuit-open circuit from 0.1 m to 0.2 m and open circuit-short circuit to 0.2 m. For the RG59 Cable at the actual distance to the fault location of 10.0 m, for the short circuit-short circuit method, the error in determining the fault location is from 0.0 m to 0.7 m, for open circuit-open circuit from 0.0 m to 0.1 m and open circuit-short circuit from 0.2 m to 0.7 m. For the RF-7 Cable with a length of 100.0 m, with the assumed distance to the fault location of 10.0 m, for the short circuit-short circuit method, the error in determining the fault location is from 0.7 m to 1.8 m, for open circuit-open circuit from 0.0 m to 0.7 m and open circuit-short circuit 0.2 m to 2.3 m. For the RF-7 Cable with the assumed distance to the fault location of 20.0 m, for the short circuit-short circuit method, the error in determining the fault location is from 0.1 m to 1.2 m, for open circuit-open circuit method from 0.1 m to 0.3 m and open circuit-short circuit method from 0.1 m to 0.7 m.
引用
收藏
页码:115231 / 115279
页数:49
相关论文
共 50 条
  • [31] Distribution Fault Location using Short-circuit Fault Current Profile Approach
    Das, S.
    Kulkarni, S.
    Karnik, N.
    Santoso, S.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [32] Impedance-based algorithm for the discrimination between inrush and short-circuit currents in single-phase transformers
    Al-Tallaq, KN
    Dahab, AER
    Abo-Zahhad, M
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2003, 31 (06) : 593 - 604
  • [33] Short-circuit Fault Classification Method for AC Submarine Cables in Offshore Wind Farms Based on Improved Sparse Representation
    Tang W.
    Liang Q.
    Zhao B.
    Xin Y.
    Gu Y.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (06): : 2212 - 2221
  • [34] Short Circuit Detection and Fault Current Limiting Method for IGBTs
    Mohamed Sathik, Mohamed Halick
    Sundararajan, Prasanth
    Sasongko, Firman
    Pou, Josep
    Vaiyapuri, Viswanathan
    IEEE TRANSACTIONS ON DEVICE AND MATERIALS RELIABILITY, 2020, 20 (04) : 686 - 693
  • [35] Calculation of Short Circuit Based on Compensation Method
    Gao, Feng
    Zhao, Xilan
    Bi, Huijing
    Huang, Gang
    PROCEEDINGS OF THE 2017 INTERNATIONAL CONFERENCE ON ELECTRONIC INDUSTRY AND AUTOMATION (EIA 2017), 2017, 145 : 44 - 48
  • [36] Short-Circuit Fault Section Location Method of Flexible Interconnected Distribution Network Based on Transient Component Similarity
    Yin, Hongxu
    Song, Liang
    Xing, Zhitong
    Chen, Wencong
    Chu, Ning
    Mao, Chenxu
    PROCEEDINGS OF 2023 INTERNATIONAL CONFERENCE ON WIRELESS POWER TRANSFER, VOL 3, ICWPT 2023, 2024, 1160 : 169 - 180
  • [37] A Stray Magnetic Flux-Based Robust Diagnosis Method for Detection and Location of Interturn Short Circuit Fault in PMSM
    Gurusamy, Vigneshwaran
    Bostanci, Emine
    Li, Chen
    Qi, Yuan
    Akin, Bilal
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [38] Study on Sweep Frequency Impedance Method for Detecting Internal Winding Short Circuit Fault in Power Transformer
    Liu, Yong
    Yang, Fan
    Liang, Xiaochen
    Ji, Shengchang
    Sun, Xiang
    Zhu, Shenghong
    Yao, Xiu
    2014 IEEE INTERNATIONAL POWER MODULATOR AND HIGH VOLTAGE CONFERENCE (IPMHVC), 2014, : 137 - 140
  • [39] A Section Location Method of Single-Phase Short-Circuit Faults for Distribution Networks Containing Distributed Generators Based on Fusion Fault Confidence of Short-Circuit Current Vectors
    Xu, Shoudong
    Ouyang, Jinxin
    Chen, Jiyu
    Xiong, Xiaofu
    ELECTRONICS, 2024, 13 (09)
  • [40] A New Method of Transformer Short-Circuit Impedance Regulation Based on Magnetic Shunts
    Ye, Zhijun
    Jia, Hao
    Cai, Wei
    Zeng, Wenhui
    ENERGIES, 2024, 17 (15)