Impedance-Based Short Circuit-Short Circuit Fault Location Method in Coaxial Cables

被引:1
|
作者
Bugajska, Aneta [1 ]
Desaniuk, Tomasz [2 ]
机构
[1] Kielce Univ Technol, Fac Elect Engn Automat Control & Comp Sci, PL-25314 Kielce, Poland
[2] Kielce Univ Technol, Fac Mechatron & Mech Engn, PL-25314 Kielce, Poland
关键词
Input impedance; transverse impedance; distance to the fault location; coaxial cable; diagnostic tests; SCHEME; WAVE;
D O I
10.1109/ACCESS.2023.3320641
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The paper presents the results of the assessment and verification of a non-destructive method of fault location in coaxial cables with a local weakening of insulation. The essence of the method is to measure the input impedance of the cable in a short circuit at both ends and, based on obtained values, to determine the transverse impedance of the fault and the distance to the fault location. For the RG59 Cable with a length of 50.0 m, with the assumed distance to the fault location of 5.0 m, for the short circuit-short circuit method, the error in determining the fault location is from 0.0 m to 1.8 m, for open circuit-open circuit from 0.1 m to 0.2 m and open circuit-short circuit to 0.2 m. For the RG59 Cable at the actual distance to the fault location of 10.0 m, for the short circuit-short circuit method, the error in determining the fault location is from 0.0 m to 0.7 m, for open circuit-open circuit from 0.0 m to 0.1 m and open circuit-short circuit from 0.2 m to 0.7 m. For the RF-7 Cable with a length of 100.0 m, with the assumed distance to the fault location of 10.0 m, for the short circuit-short circuit method, the error in determining the fault location is from 0.7 m to 1.8 m, for open circuit-open circuit from 0.0 m to 0.7 m and open circuit-short circuit 0.2 m to 2.3 m. For the RF-7 Cable with the assumed distance to the fault location of 20.0 m, for the short circuit-short circuit method, the error in determining the fault location is from 0.1 m to 1.2 m, for open circuit-open circuit method from 0.1 m to 0.3 m and open circuit-short circuit method from 0.1 m to 0.7 m.
引用
收藏
页码:115231 / 115279
页数:49
相关论文
共 50 条
  • [21] Short-circuit impedance measurement
    Pedersen, KOH
    Nielsen, AH
    Poulsen, NK
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2003, 150 (02) : 169 - 174
  • [22] Fault Location Method for Phase-to-phase Short Circuit in Flexible Interconnected Distribution Network Based on SOP
    Zheng, Tao
    Shen, Wentao
    Lyu, Wenxuan
    Yang, Yi
    Xue, Yushi
    Dianwang Jishu/Power System Technology, 2024, 48 (12): : 5118 - 5128
  • [23] Fault location observability rules for impedance-based fault location algorithms
    Dolatabadi, Sayed Hamid Hosseini
    Golshan, Mohammad Esmail Hamedani
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 224
  • [24] A Calculation Method to Adjust the Short-Circuit Impedance of a Transformer
    Ye, Zhijun
    Yu, Wang
    Gou, Julong
    Tan, Kaijia
    Zeng, Wenhui
    An, Bonan
    Li, Yong
    IEEE ACCESS, 2020, 8 : 223848 - 223858
  • [25] Short-circuit Fault Location method for Smart Distribution Network Considering load estimation
    Xing, Xiaodong
    Zhang, Hengxu
    Shi, Fang
    Liu, Weisheng
    Liu, Yuanlong
    Ling, Ping
    Bao, Hailong
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [26] The simulation of T-F short-circuit fault location in all parallel AT traction power supply system based on the subsection impedance method
    Gao, Zhaohui
    Wang, Jiangfeng
    He, Zhengyou
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [27] Impedance-Based Fault Location Algorithm for Double-Circuit Transmission Lines Using Single-End Data
    Nemati, Mojtaba
    Bigdeli, Mehdi
    Ghorbani, Amir
    JOURNAL OF CONTROL AUTOMATION AND ELECTRICAL SYSTEMS, 2020, 31 (05) : 1267 - 1277
  • [28] A Unified Impedance-Based Fault Location Method for Generalized Distribution Systems
    Ferreira, Gustavo D.
    Gazzana, Daniel S.
    Bretas, Arturo S.
    Netto, Afonso S.
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [29] Impedance-Based Fault Location Algorithm for Double-Circuit Transmission Lines Using Single-End Data
    Mojtaba Nemati
    Mehdi Bigdeli
    Amir Ghorbani
    Journal of Control, Automation and Electrical Systems, 2020, 31 : 1267 - 1277
  • [30] A New Impedance-Based Fault Location Method for Radial Distribution Systems
    Ramar, K.
    Ngu, E. E.
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,